flowInterfaceSampleRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter N for statistical counting on this interface.
Set to N to count 1/Nth of the packets appearing at this
interface. A sampling rate of 1 counts all packets.
A sampling rate of 0 results in the interface being ignored
by the meter.
A meter should choose its own algorithm to introduce variance
into the sampling so that exactly every Nth packet is counted.
The IPPM Working Groups RFC Framework for IP Performance
Metrics [IPPM-FRM] explains why this should be done, and sets
out an algorithm for doing it."
DEFVAL { 1 }
View at oid-info.com
The parameter N for statistical counting on this interface.
Set to N to count 1/Nth of the packets appearing at this
interface. A sampling rate of 1 counts all packets.
A sampling rate of 0 results in the interface being ignored
by the meter.
A meter should choose its own algorithm to introduce variance
into the sampling so that exactly every Nth packet is counted.
The IPPM Working Group's RFC 'Framework for IP Performance
Metrics' [IPPM-FRM] explains why this should be done, and sets
out an algorithm for doing it.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
The parameter N for statistical counting on this interface.
Set to N to count 1/Nth of the packets appearing at this
interface. A sampling rate of 1 counts all packets.
A sampling rate of 0 results in the interface being ignored
by the meter.
A meter should choose its own algorithm to introduce variance
into the sampling so that exactly every Nth packet is counted.
The IPPM Working Group's RFC 'Framework for IP Performance
Metrics' [IPPM-FRM] explains why this should be done, and sets
out an algorithm for doing it.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowInterfaceSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all packets. A sampling rate of 0 results in the interface being ignored by the meter. A meter should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is counted. The IPPM Working Group's RFC 'Framework for IP Performance Metrics' [IPPM-FRM] explains why this should be done, and sets out an algorithm for doing it." DEFVAL { 1 } ::= { flowInterfaceEntry 1 }
flowInterfaceSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all packets. A sampling rate of 0 results in the interface being ignored by the meter. A meter should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is counted. The IPPM Working Group's RFC 'Framework for IP Performance Metrics' [IPPM-FRM] explains why this should be done, and sets out an algorithm for doing it." DEFVAL { 1 } ::= { flowInterfaceEntry 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.2.1.2 | flowInterfaceLostPackets | 0 | 0 | The number of packets the meter has lost for this interface. Such losses may occur because the meter has been unable to keep up w… |