Reference record for OID 1.3.6.1.2.1.40.1.2.1.1


parent
1.3.6.1.2.1.40.1.2.1 (flowInterfaceEntry)
node code
1
node names
  • flowInterfaceSampleRate
  • flowInterfaceRate
  • dot oid
    1.3.6.1.2.1.40.1.2.1.1
    type
    OBJECT-TYPE
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceSampleRate(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceRate(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceSampleRate(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceRate(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceSampleRate(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceRate(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceSampleRate(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowControl(1) flowInterfaceTable(2) flowInterfaceEntry(1) flowInterfaceRate(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceSampleRate
  • /iso/identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceRate
  • ...skipped...
  • /iso/org/dod/internet/mgmt/mib-2/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceSampleRate
  • /iso/org/dod/internet/mgmt/mib-2/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceRate
  • /iso/org/dod/internet/mgmt/mib/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceSampleRate
  • /iso/org/dod/internet/mgmt/mib/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceRate
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceSampleRate
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/flowMIB/flowControl/flowInterfaceTable/flowInterfaceEntry/flowInterfaceRate
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/40/1/2/1/1

    Description by oid_info

    flowInterfaceSampleRate OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The parameter N for statistical counting on this interface.
    Set to N to count 1/Nth of the packets appearing at this
    interface. A sampling rate of 1 counts all packets.
    A sampling rate of 0 results in the interface being ignored
    by the meter.
    A meter should choose its own algorithm to introduce variance
    into the sampling so that exactly every Nth packet is counted.
    The IPPM Working Groups RFC Framework for IP Performance
    Metrics [IPPM-FRM] explains why this should be done, and sets
    out an algorithm for doing it."
    DEFVAL { 1 }

    View at oid-info.com

    Description by mibdepot

    The parameter N for statistical counting on this interface.
    Set to N to count 1/Nth of the packets appearing at this
    interface. A sampling rate of 1 counts all packets.
    A sampling rate of 0 results in the interface being ignored
    by the meter.

    A meter should choose its own algorithm to introduce variance
    into the sampling so that exactly every Nth packet is counted.
    The IPPM Working Group's RFC 'Framework for IP Performance
    Metrics' [IPPM-FRM] explains why this should be done, and sets
    out an algorithm for doing it.

    Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
    Company: None
    Module: FLOW-METER-MIB

    Description by circitor

    The parameter N for statistical counting on this interface.
    Set to N to count 1/Nth of the packets appearing at this
    interface. A sampling rate of 1 counts all packets.
    A sampling rate of 0 results in the interface being ignored
    by the meter.

    A meter should choose its own algorithm to introduce variance
    into the sampling so that exactly every Nth packet is counted.
    The IPPM Working Group's RFC 'Framework for IP Performance
    Metrics' [IPPM-FRM] explains why this should be done, and sets
    out an algorithm for doing it.

    Parsed from file FLOW-METER-MIB.mib
    Module: FLOW-METER-MIB

    Information by oid_info

    Automatically extracted from RFC2720

    Information by mibdepot

    flowInterfaceSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all packets. A sampling rate of 0 results in the interface being ignored by the meter. A meter should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is counted. The IPPM Working Group's RFC 'Framework for IP Performance Metrics' [IPPM-FRM] explains why this should be done, and sets out an algorithm for doing it." DEFVAL { 1 } ::= { flowInterfaceEntry 1 }

    Information by circitor

    flowInterfaceSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all packets. A sampling rate of 0 results in the interface being ignored by the meter. A meter should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is counted. The IPPM Working Group's RFC 'Framework for IP Performance Metrics' [IPPM-FRM] explains why this should be done, and sets out an algorithm for doing it." DEFVAL { 1 } ::= { flowInterfaceEntry 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.40.1.2.1.2 flowInterfaceLostPackets 0 0 The number of packets the meter has lost for this interface.
    Such losses may occur because the meter has been unable to
    keep up w…