flowFloodMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates that the meter has passed its FloodMark and is
not running in its normal mode.
When the manager notices this it should take action to remedy
the problem which caused the flooding. It should then monitor
flowActiveFlows so as to determine when the flood has receded.
At that point the manager may set flowFloodMode to false(2) to
resume normal operation."
View at oid-info.com
Indicates that the meter has passed its FloodMark and is
not running in its normal mode.
When the manager notices this it should take action to remedy
the problem which caused the flooding. It should then monitor
flowActiveFlows so as to determine when the flood has receded.
At that point the manager may set flowFloodMode to false(2) to
resume normal operation.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
Indicates that the meter has passed its FloodMark and is
not running in its normal mode.
When the manager notices this it should take action to remedy
the problem which caused the flooding. It should then monitor
flowActiveFlows so as to determine when the flood has receded.
At that point the manager may set flowFloodMode to false(2) to
resume normal operation.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowFloodMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that the meter has passed its FloodMark and is not running in its normal mode. When the manager notices this it should take action to remedy the problem which caused the flooding. It should then monitor flowActiveFlows so as to determine when the flood has receded. At that point the manager may set flowFloodMode to false(2) to resume normal operation." ::= { flowControl 9 }
flowFloodMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that the meter has passed its FloodMark and is not running in its normal mode. When the manager notices this it should take action to remedy the problem which caused the flooding. It should then monitor flowActiveFlows so as to determine when the flood has receded. At that point the manager may set flowFloodMode to false(2) to resume normal operation." ::= { flowControl 9 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.9.0 | flowFloodMode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.1 | flowRuleSetInfoTable | 1 | 9 | An array of information about the RuleSets held in the meter. Any manager may configure a new RuleSet for the meter by creating a … |
1.3.6.1.2.1.40.1.2 | flowInterfaceTable | 1 | 3 | An array of information specific to each meter interface. |
1.3.6.1.2.1.40.1.3 | flowReaderInfoTable | 1 | 8 | An array of information about meter readers which have registered their intent to collect flow data from this meter. |
1.3.6.1.2.1.40.1.4 | flowManagerInfoTable | 1 | 10 | An array of information about managers which have registered their intent to run RuleSets on this meter. |
1.3.6.1.2.1.40.1.5 | flowFloodMark | 1 | 1 | A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it shoul… |
1.3.6.1.2.1.40.1.6 | flowInactivityTimeout | 1 | 1 | The time in seconds since the last packet seen, after which a flow becomes 'idle.' Note that although a flow may be idle, it wil… |
1.3.6.1.2.1.40.1.7 | flowActiveFlows | 1 | 1 | The number of flows which are currently in use. |
1.3.6.1.2.1.40.1.8 | flowMaxFlows | 1 | 1 | The maximum number of flows allowed in the meter's flow table. At present this is determined when the meter is first started up. |