Reference record for OID 1.3.6.1.2.1.40.2.1.1.25


parent
1.3.6.1.2.1.40.2.1.1 (flowDataEntry)
node code
25
node name
flowDataOctetScale
dot oid
1.3.6.1.2.1.40.2.1.1.25
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataTable(1) flowDataEntry(1) flowDataOctetScale(25)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • /iso/identified-organization/dod/internet/mgmt/mib/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • /iso/org/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • /iso/org/dod/internet/mgmt/mib/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/flowMIB/flowData/flowDataTable/flowDataEntry/flowDataOctetScale
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/40/2/1/1/25

    Description by oid_info

    flowDataOctetScale OBJECT-TYPE
    SYNTAX Integer32 (0..255)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "The scale factor applied to this particular flow. Indicates
    the number of bits the octet counter values should be moved
    left to obtain the actual values."

    View at oid-info.com

    Description by mibdepot

    The scale factor applied to this particular flow. Indicates
    the number of bits the octet counter values should be moved
    left to obtain the actual values.

    Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
    Company: None
    Module: FLOW-METER-MIB

    Description by circitor

    The scale factor applied to this particular flow. Indicates
    the number of bits the octet counter values should be moved
    left to obtain the actual values.

    Parsed from file FLOW-METER-MIB.mib
    Module: FLOW-METER-MIB

    Information by oid_info

    Automatically extracted from RFC2720

    Information by mibdepot

    flowDataOctetScale OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The scale factor applied to this particular flow. Indicates the number of bits the octet counter values should be moved left to obtain the actual values." ::= { flowDataEntry 25 }

    Information by circitor

    flowDataOctetScale OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The scale factor applied to this particular flow. Indicates the number of bits the octet counter values should be moved left to obtain the actual values." ::= { flowDataEntry 25 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (40)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.40.2.1.1.1 flowDataIndex 0 0 Value of this flow data record's index within the meter's
    flow table.
    1.3.6.1.2.1.40.2.1.1.2 flowDataTimeMark 0 0 A TimeFilter for this entry. Allows GetNext and GetBulk
    to find flow table rows which have changed since a specified
    value of th…
    1.3.6.1.2.1.40.2.1.1.3 flowDataStatus 0 0 Status of this flow data record.
    1.3.6.1.2.1.40.2.1.1.4 flowDataSourceInterface 0 0 Index of the interface associated with the source address
    for this flow. It's value is one of those contained in the
    ifIndex fie…
    1.3.6.1.2.1.40.2.1.1.5 flowDataSourceAdjacentType 0 0 Adjacent address type of the source for this flow.

    If metering is being performed at the network level,
    AdjacentType will indicat…
    1.3.6.1.2.1.40.2.1.1.6 flowDataSourceAdjacentAddress 0 0 Address of the adjacent device on the path for the source
    for this flow.
    1.3.6.1.2.1.40.2.1.1.7 flowDataSourceAdjacentMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the adjacent source address for this flow.
    1.3.6.1.2.1.40.2.1.1.8 flowDataSourcePeerType 0 0 Peer address type of the source for this flow.
    1.3.6.1.2.1.40.2.1.1.9 flowDataSourcePeerAddress 0 0 Address of the peer device for the source of this flow.
    1.3.6.1.2.1.40.2.1.1.10 flowDataSourcePeerMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the source peer address for this flow.
    1.3.6.1.2.1.40.2.1.1.11 flowDataSourceTransType 0 0 Transport address type of the source for this flow. The
    value of this attribute will depend on the peer address type.
    1.3.6.1.2.1.40.2.1.1.12 flowDataSourceTransAddress 0 0 Transport address for the source of this flow.
    1.3.6.1.2.1.40.2.1.1.13 flowDataSourceTransMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the transport source address for this flow.
    1.3.6.1.2.1.40.2.1.1.14 flowDataDestInterface 0 0 Index of the interface associated with the dest address for
    this flow. This value is one of the values contained in the
    ifIndex …
    1.3.6.1.2.1.40.2.1.1.15 flowDataDestAdjacentType 0 0 Adjacent address type of the destination for this flow.
    1.3.6.1.2.1.40.2.1.1.16 flowDataDestAdjacentAddress 0 0 Address of the adjacent device on the path for the
    destination for this flow.
    1.3.6.1.2.1.40.2.1.1.17 flowDataDestAdjacentMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the adjacent destination address for this flow.
    1.3.6.1.2.1.40.2.1.1.18 flowDataDestPeerType 0 0 Peer address type of the destination for this flow.
    1.3.6.1.2.1.40.2.1.1.19 flowDataDestPeerAddress 0 0 Address of the peer device for the destination of this flow.
    1.3.6.1.2.1.40.2.1.1.20 flowDataDestPeerMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the destination peer type for this flow.
    1.3.6.1.2.1.40.2.1.1.21 flowDataDestTransType 0 0 Transport address type of the destination for this flow. The
    value of this attribute will depend on the peer address type.
    1.3.6.1.2.1.40.2.1.1.22 flowDataDestTransAddress 0 0 Transport address for the destination of this flow.
    1.3.6.1.2.1.40.2.1.1.23 flowDataDestTransMask 0 0 1-bits in this mask indicate which bits must match when
    comparing the transport destination address for this flow.
    1.3.6.1.2.1.40.2.1.1.24 flowDataPDUScale 0 0 The scale factor applied to this particular flow. Indicates
    the number of bits the PDU counter values should be moved left
    to ob…
    1.3.6.1.2.1.40.2.1.1.26 flowDataRuleSet 0 0 The RuleSet number of the RuleSet which created this flow.
    Allows a manager to use GetNext or GetBulk requests to find
    flows belo…
    1.3.6.1.2.1.40.2.1.1.27 flowDataToOctets 0 0 The count of octets flowing from source to destination
    for this flow.
    1.3.6.1.2.1.40.2.1.1.28 flowDataToPDUs 0 0 The count of packets flowing from source to destination
    for this flow.
    1.3.6.1.2.1.40.2.1.1.29 flowDataFromOctets 0 0 The count of octets flowing from destination to source
    for this flow.
    1.3.6.1.2.1.40.2.1.1.30 flowDataFromPDUs 0 0 The count of packets flowing from destination to source
    for this flow.
    1.3.6.1.2.1.40.2.1.1.31 flowDataFirstTime 0 0 The time at which this flow was first entered in the table
    1.3.6.1.2.1.40.2.1.1.32 flowDataLastActiveTime 0 0 The last time this flow had activity, i.e. the time of
    arrival of the most recent PDU belonging to this flow.
    1.3.6.1.2.1.40.2.1.1.33 flowDataSourceSubscriberID 0 0 Subscriber ID associated with the source address for this
    flow. A Subscriber ID is an unspecified text string, used
    to ascribe t…
    1.3.6.1.2.1.40.2.1.1.34 flowDataDestSubscriberID 0 0 Subscriber ID associated with the destination address for
    this flow. A Subscriber ID is an unspecified text string,
    used to ascr…
    1.3.6.1.2.1.40.2.1.1.35 flowDataSessionID 0 0 Session ID for this flow. Such an ID might be allocated
    by a network access server to distinguish a series of sessions
    between t…
    1.3.6.1.2.1.40.2.1.1.36 flowDataSourceClass 0 0 Source class for this flow. Determined by the rules, set by
    a PushRule action when this flow was entered in the table.
    1.3.6.1.2.1.40.2.1.1.37 flowDataDestClass 0 0 Destination class for this flow. Determined by the rules, set
    by a PushRule action when this flow was entered in the table.
    1.3.6.1.2.1.40.2.1.1.38 flowDataClass 0 0 Class for this flow. Determined by the rules, set by a
    PushRule action when this flow was entered in the table.
    1.3.6.1.2.1.40.2.1.1.39 flowDataSourceKind 0 0 Source kind for this flow. Determined by the rules, set by
    a PushRule action when this flow was entered in the table.
    1.3.6.1.2.1.40.2.1.1.40 flowDataDestKind 0 0 Destination kind for this flow. Determined by the rules, set
    by a PushRule action when this flow was entered in the table.
    1.3.6.1.2.1.40.2.1.1.41 flowDataKind 0 0 Class for this flow. Determined by the rules, set by a
    PushRule action when this flow was entered in the table.