Reference record for OID 1.3.6.1.2.1.40.2.3


parent
1.3.6.1.2.1.40.2 (flowData)
node code
3
node name
flowDataPackageTable
dot oid
1.3.6.1.2.1.40.2.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) flowMIB(40) flowData(2) flowDataPackageTable(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataPackageTable
  • /iso/identified-organization/dod/internet/mgmt/mib/flowMIB/flowData/flowDataPackageTable
  • /iso/org/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataPackageTable
  • /iso/org/dod/internet/mgmt/mib/flowMIB/flowData/flowDataPackageTable
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/flowMIB/flowData/flowDataPackageTable
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/flowMIB/flowData/flowDataPackageTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/40/2/3

    Description by oid_info

    flowDataPackageTable OBJECT-TYPE
    SYNTAX SEQUENCE OF FlowDataPackageEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "Index into the Flow Table. Allows a meter reader to retrieve
    a sequence containing the values of a specified set of
    attributes for a flow which came from a specified RuleSet and
    which was last active at or after a given time."

    View at oid-info.com

    Description by mibdepot

    Index into the Flow Table. Allows a meter reader to retrieve
    a sequence containing the values of a specified set of
    attributes for a flow which came from a specified RuleSet and
    which was last active at or after a given time.

    Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
    Company: None
    Module: FLOW-METER-MIB

    Description by circitor

    Index into the Flow Table. Allows a meter reader to retrieve
    a sequence containing the values of a specified set of
    attributes for a flow which came from a specified RuleSet and
    which was last active at or after a given time.

    Parsed from file FLOW-METER-MIB.mib
    Module: FLOW-METER-MIB

    Information by oid_info

    Automatically extracted from RFC2720

    Information by mibdepot

    flowDataPackageTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowDataPackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into the Flow Table. Allows a meter reader to retrieve a sequence containing the values of a specified set of attributes for a flow which came from a specified RuleSet and which was last active at or after a given time." ::= { flowData 3 }

    Information by circitor

    flowDataPackageTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowDataPackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into the Flow Table. Allows a meter reader to retrieve a sequence containing the values of a specified set of attributes for a flow which came from a specified RuleSet and which was last active at or after a given time." ::= { flowData 3 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.40.2.3.1 flowDataPackageEntry 5 5 The data package containing selected variables from
    active rows in the flow table.

    Brothers (2)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.40.2.1 flowDataTable 1 42 The list of all flows being measured.
    1.3.6.1.2.1.40.2.2 flowColumnActivityTable 1 5 Index into the Flow Table. Allows a meter reader to retrieve
    a list containing the flow table indexes of flows which were
    last a…