The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnits (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this
parameter.
Parsed from file Printer-MIB.mib
Module: Printer-MIB
The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnits (as specified
by prtMarkerDefaultIndex) for this interpreter. The
value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtInterpreterFeedAddressability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter."
View at oid-info.com
The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter.
Parsed from file rfc1759.mib.txt
Company: None
Module: Printer-MIB
The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnits (as specified
by prtMarkerDefaultIndex) for this interpreter. The
value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 8 }
prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX INTEGER(-2..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (as specified by prtMarkerDefaultIndex) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtInterpreterEntry 8 }
Automatically extracted from RFC1759
prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 8 }
prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX Integer32 (-2..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnits (as specified by prtMarkerDefaultIndex) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtInterpreterEntry 8 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.43.15.1.1.1 | prtInterpreterIndex | 0 | 0 | A unique value for each PDL or control language for which there exists an interpreter or emulator in the printer. The value is us… |
1.3.6.1.2.1.43.15.1.1.2 | prtInterpreterLangFamily | 0 | 0 | The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or e… |
1.3.6.1.2.1.43.15.1.1.3 | prtInterpreterLangLevel | 0 | 0 | The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e'for an interp… |
1.3.6.1.2.1.43.15.1.1.4 | prtInterpreterLangVersion | 0 | 0 | The date code or version of the language which this interpreter is interpreting or emulating. |
1.3.6.1.2.1.43.15.1.1.5 | prtInterpreterDescription | 0 | 0 | A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language w… |
1.3.6.1.2.1.43.15.1.1.6 | prtInterpreterVersion | 0 | 0 | The date code, version number, or other product specific information tied to this interpreter. This value is associated with the… |
1.3.6.1.2.1.43.15.1.1.7 | prtInterpreterDefaultOrientation | 0 | 0 | The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in th… |
1.3.6.1.2.1.43.15.1.1.9 | prtInterpreterXFeedAddressability | 0 | 0 | The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnits (see prtMarkerAddressabi… |
1.3.6.1.2.1.43.15.1.1.10 | prtInterpreterDefaultCharSetIn | 0 | 0 | The default coded character set for input octets encountered outside a context in which the Page Description Language established… |
1.3.6.1.2.1.43.15.1.1.11 | prtInterpreterDefaultCharSetOut | 0 | 0 | The default character set for data coming from this interpreter through the printer's output channel (i.e. the 'backchannel'). |
1.3.6.1.2.1.43.15.1.1.12 | prtInterpreterTwoWay | 0 | 0 | Indicates whether or not this interpreter returns information back to the host. |