Reference record for OID 1.3.6.1.2.1.43.17.6.1.1


parent
1.3.6.1.2.1.43.17.6.1 (prtConsoleLightEntry)
node code
1
node name
prtConsoleLightIndex
dot oid
1.3.6.1.2.1.43.17.6.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) printmib(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) current-printing-job-pages-printed(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) job-info-change-id(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) release-held-job(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) printmib(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) current-printing-job-pages-printed(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) job-info-change-id(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) release-held-job(43) prtConsoleLights(17) prtConsoleLightTable(6) prtConsoleLightEntry(1) prtConsoleLightIndex(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/printmib/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • /iso/identified-organization/dod/internet/mgmt/mib-2/current-printing-job-pages-printed/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • ...skipped...
  • /iso/org/dod/internet/mgmt/mib-2/job-info-change-id/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • /iso/org/dod/internet/mgmt/mib-2/release-held-job/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • /iso/org/dod/internet/mgmt/mib/printmib/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • /iso/org/dod/internet/mgmt/mib/current-printing-job-pages-printed/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/job-info-change-id/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/release-held-job/prtConsoleLights/prtConsoleLightTable/prtConsoleLightEntry/prtConsoleLightIndex
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/43/17/6/1/1

    Description by circitor

    A unique value used by the printer to identify this
    light. Although these values may change due to a major
    reconfiguration of the device (e.g. the addition of new
    lights to the printer). Values are normally expected to
    remain stable across successive printer power cycles.

    Parsed from file Printer-MIB.mib
    Module: Printer-MIB

    Description by cisco_v1

    A unique value used by the printer to identify this light.
    Although these values may change due to a major
    reconfiguration of the device (e.g., the addition of new lights
    to the printer). Values SHOULD remain stable across successive
    printer power cycles.

    NOTE: The above description has been modified from RFC 1759
    for clarification.

    Description by oid_info

    prtConsoleLightIndex OBJECT-TYPE
    SYNTAX Integer32 (0..65535)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "A unique value used by the printer to identify this light.
    Although these values may change due to a major
    reconfiguration of the device (e.g. the addition of new lights
    to the printer), values are expected to remain stable across
    successive printer power cycles."

    View at oid-info.com

    Description by mibdepot

    A unique value used by the printer to identify this light.
    Although these values may change due to a major
    reconfiguration of the device (e.g. the addition of new lights
    to the printer), values are expected to remain stable across
    successive printer power cycles.

    Parsed from file rfc1759.mib.txt
    Company: None
    Module: Printer-MIB

    Description by cisco

    A unique value used by the printer to identify this light.
    Although these values may change due to a major
    reconfiguration of the device (e.g., the addition of new lights
    to the printer). Values SHOULD remain stable across successive
    printer power cycles.

    NOTE: The above description has been modified from RFC 1759
    for clarification.

    Information by circitor

    prtConsoleLightIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer). Values are normally expected to remain stable across successive printer power cycles." ::= { prtConsoleLightEntry 1 }

    Information by cisco_v1

    prtConsoleLightIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new lights to the printer). Values SHOULD remain stable across successive printer power cycles. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtConsoleLightEntry 1 }

    Information by oid_info

    Automatically extracted from RFC1759

    Information by mibdepot

    prtConsoleLightIndex OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtConsoleLightEntry 1 }

    Information by cisco

    prtConsoleLightIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new lights to the printer). Values SHOULD remain stable across successive printer power cycles. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtConsoleLightEntry 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.43.17.6.1.2 prtConsoleOnTime 0 0 The on time in milliseconds of blinking of this light; 0
    indicates off always. If both prtConsoleOnTime
    and prtConsoleOffTime ar…
    1.3.6.1.2.1.43.17.6.1.3 prtConsoleOffTime 0 0 The off time in milliseconds of blinking of this light; 0
    indicates on always. If both prtConsoleOnTime
    and prtConsoleOffTime ar…
    1.3.6.1.2.1.43.17.6.1.4 prtConsoleColor 0 0 The color of this light.
    1.3.6.1.2.1.43.17.6.1.5 prtConsoleDescription 0 0 The vendor description or label of this light in the
    localization specified by prtConsoleLocalization.