Reference record for OID 1.3.6.1.2.1.80.2.1.3


parent
1.3.6.1.2.1.80.2.1 (pingCompliances)
node code
3
node name
pingMinimumCompliance
dot oid
1.3.6.1.2.1.80.2.1.3
type
MODULE-COMPLIANCE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) pingMIB(80) pingConformance(2) pingCompliances(1) pingMinimumCompliance(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • /iso/identified-organization/dod/internet/mgmt/mib/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • /iso/org/dod/internet/mgmt/mib-2/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • /iso/org/dod/internet/mgmt/mib/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/pingMIB/pingConformance/pingCompliances/pingMinimumCompliance
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/80/2/1/3

    Description by oid_info

    pingMinimumCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
    "The minimum compliance statement for SNMP entities
    that implement the minimal subset of the
    DISMAN-PING-MIB. Implementors might choose this
    subset for small devices with limited resources."
    MODULE -- this module
    MANDATORY-GROUPS { pingMinimumGroup }
    GROUP pingCtlRowStatusGroup
    DESCRIPTION
    "A compliant implementation does not have to implement
    the pingCtlRowStatusGroup."
    GROUP pingHistoryGroup
    DESCRIPTION
    "A compliant implementation does not have to implement
    the pingHistoryGroup."
    GROUP pingNotificationsGroup
    DESCRIPTION
    "A compliant implementation does not have to implement
    the pingNotificationsGroup."
    OBJECT pingMaxConcurrentRequests
    MIN-ACCESS read-only
    DESCRIPTION
    "The agent is not required to support set
    operations to this object."
    OBJECT pingCtlDataFill
    MIN-ACCESS read-only
    DESCRIPTION
    "The agent is not required to support set
    operations to this object."
    OBJECT pingCtlFrequency
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If write access is
    not supported, return a 0 as the value of this object.
    A value of 0 means that the function represented by
    this option is not supported."
    OBJECT pingCtlMaxRows
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If the
    pingHistoryGroup is not implemented, then write
    access to this object MUST be disabled, and the object
    MUST return a value of 0 when retrieved."
    OBJECT pingCtlStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT pingCtlTrapGeneration
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If the
    pingNotificationsGroup is not implemented, then write
    access to this object MUST be disabled, and the object
    MUST return a value with no bit set when retrieved.
    No bit set indicates that not notification is
    generated."
    OBJECT pingCtlTrapProbeFailureFilter
    MIN-ACCESS read-only
    DESCRIPTION
    "If write access to pingCtlTrapGeneration is not
    supported, then write access to this object must also
    not be supported. In this case, return 0 as the value
    of this object."
    OBJECT pingCtlTrapTestFailureFilter
    MIN-ACCESS read-only
    DESCRIPTION
    "If write access to pingCtlTrapGeneration is not
    supported, then write access to this object must also
    not be supported. In this case, return 0 as the value
    of this object."
    OBJECT pingCtlType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. In addition, the only
    value that MUST be supported by an implementation is
    pingIcmpEcho."
    OBJECT pingCtlDescr
    MIN-ACCESS read-only
    DESCRIPTION
    "The agent is not required to support set
    operations to this object."
    OBJECT pingCtlSourceAddressType
    SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access to this object is not required by
    implementations that are not capable of binding the
    send socket with a source address. An implementation
    is only required to support IPv4 and IPv6 addresses."
    OBJECT pingCtlSourceAddress
    SYNTAX InetAddress (SIZE(0|4|16))
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access to this object is not required by
    implementations that are not capable of binding the
    send socket with a source address. An implementation
    is only required to support IPv4 and IPv6 addresses."
    OBJECT pingCtlIfIndex
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If write access is
    not supported, return a 0 as the value of this object.
    A value of 0 means that the function represented by
    this option is not supported."
    OBJECT pingCtlByPassRouteTable
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If write access is
    not supported, return false(2) as the value of this
    object. A value of false(2) means that the function
    represented by this option is not supported."
    OBJECT pingCtlDSField
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. If write access is
    not supported, return a 0 as the value of this object.
    A value of 0 means that the function represented by
    this option is not supported."
    OBJECT pingResultsIpTargetAddressType
    SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
    DESCRIPTION
    "An implementation is only required to
    support IPv4 and IPv6 addresses."
    OBJECT pingResultsIpTargetAddress
    SYNTAX InetAddress (SIZE(0|4|16))
    DESCRIPTION
    "An implementation is only required to
    support IPv4 and globally unique IPv6 addresses."
    OBJECT pingResultsLastGoodProbe
    DESCRIPTION
    "This object is mandatory for implementations that have
    access to a system clock and that are capable of setting
    the values for DateAndTime objects. It is RECOMMENDED
    that when this object is not supported its values
    be reported as \0000000000000000\H."
    OBJECT pingProbeHistoryTime
    DESCRIPTION
    "If the pingHistoryGroup is implemented, then this
    object is mandatory for implementations that have
    access to a system clock and that are capable of setting
    the values for DateAndTime objects. It is RECOMMENDED
    that when this object is not supported its values
    be reported as \0000000000000000\H."

    View at oid-info.com

    Description by mibdepot

    The minimum compliance statement for SNMP entities
    that implement the minimal subset of the
    DISMAN-PING-MIB. Implementors might choose this
    subset for small devices with limited resources.

    Parsed from file DISMAN-PING-MIB.txt
    Company: riverstone
    Module: DISMAN-PING-MIB

    Information by oid_info

    Automatically extracted from RFC4560

    Information by mibdepot

    pingMinimumCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The minimum compliance statement for SNMP entities that implement the minimal subset of the DISMAN-PING-MIB. Implementors might choose this subset for small devices with limited resources." MODULE MANDATORY-GROUPS { pingMinimumGroup } GROUP pingCtlRowStatusGroup DESCRIPTION "A compliant implementation does not have to implement the pingCtlRowStatusGroup." GROUP pingHistoryGroup DESCRIPTION "A compliant implementation does not have to implement the pingHistoryGroup." GROUP pingNotificationsGroup DESCRIPTION "A compliant implementation does not have to implement the pingNotificationsGroup." OBJECT pingMaxConcurrentRequests MIN-ACCESS read-only DESCRIPTION "The agent is not required to support set operations to this object." OBJECT pingCtlDataFill MIN-ACCESS read-only DESCRIPTION "The agent is not required to support set operations to this object." OBJECT pingCtlFrequency MIN-ACCESS read-only DESCRIPTION "Write access is not required. If write access is not supported, return a 0 as the value of this object. A value of 0 means that the function represented by this option is not supported." OBJECT pingCtlMaxRows MIN-ACCESS read-only DESCRIPTION "Write access is not required. If the pingHistoryGroup is not implemented, then write access to this object MUST be disabled, and the object MUST return a value of 0 when retrieved." OBJECT pingCtlStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT pingCtlTrapGeneration MIN-ACCESS read-only DESCRIPTION "Write access is not required. If the pingNotificationsGroup is not implemented, then write access to this object MUST be disabled, and the object MUST return a value with no bit set when retrieved. No bit set indicates that not notification is generated." OBJECT pingCtlTrapProbeFailureFilter MIN-ACCESS read-only DESCRIPTION "If write access to pingCtlTrapGeneration is not supported, then write access to this object must also not be supported. In this case, return 0 as the value of this object." OBJECT pingCtlTrapTestFailureFilter MIN-ACCESS read-only DESCRIPTION "If write access to pingCtlTrapGeneration is not supported, then write access to this object must also not be supported. In this case, return 0 as the value of this object." OBJECT pingCtlType MIN-ACCESS read-only DESCRIPTION "Write access is not required. In addition, the only value that MUST be supported by an implementation is pingIcmpEcho." OBJECT pingCtlDescr MIN-ACCESS read-only DESCRIPTION "The agent is not required to support set operations to this object." OBJECT pingCtlSourceAddressType SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required by implementations that are not capable of binding the send socket with a source address. An implementation is only required to support IPv4 and IPv6 addresses." OBJECT pingCtlSourceAddress SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access to this object is not required by implementations that are not capable of binding the send socket with a source address. An implementation is only required to support IPv4 and IPv6 addresses." OBJECT pingCtlIfIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required. If write access is not supported, return a 0 as the value of this object. A value of 0 means that the function represented by this option is not supported." OBJECT pingCtlByPassRouteTable MIN-ACCESS read-only DESCRIPTION "Write access is not required. If write access is not supported, return false(2) as the value of this object. A value of false(2) means that the function represented by this option is not supported." OBJECT pingCtlDSField MIN-ACCESS read-only DESCRIPTION "Write access is not required. If write access is not supported, return a 0 as the value of this object. A value of 0 means that the function represented by this option is not supported." OBJECT pingResultsIpTargetAddressType SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } DESCRIPTION "An implementation is only required to support IPv4 and IPv6 addresses." OBJECT pingResultsIpTargetAddress SYNTAX InetAddress (SIZE(0|4|16)) DESCRIPTION "An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT pingResultsLastGoodProbe DESCRIPTION "This object is mandatory for implementations that have access to a system clock and that are capable of setting the values for DateAndTime objects. It is RECOMMENDED that when this object is not supported its values be reported as '0000000000000000'H." OBJECT pingProbeHistoryTime DESCRIPTION "If the pingHistoryGroup is implemented, then this object is mandatory for implementations that have access to a system clock and that are capable of setting the values for DateAndTime objects. It is RECOMMENDED that when this object is not supported its values be reported as '0000000000000000'H." ::= { pingCompliances 3 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (2)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.80.2.1.1 pingCompliance 0 0 The compliance statement for the DISMAN-PING-MIB.
    1.3.6.1.2.1.80.2.1.2 pingFullCompliance 0 0 The compliance statement for SNMP entities that
    fully implement the DISMAN-PING-MIB.