frAtmIwfConnRowStatus OBJECT-TYPE SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The table row may be created with
createAndWait(5) or createAndGo(4).
To activate a connection entry, a valid connection
descriptor MUST be established in the
frAtmIwfConnectionDescriptor object.
This object is set to destroy(6) to delete the
table row. Before the table row is destroyed, the
OperStatus/AdminStatus of the corresponding
endpoints MUST be down(2). The deactivation of
the ATM endpoint MAY occur as a side-effect of
deleting the FR/ATM IWF cross-connection table
row. Otherwise, destroy(6) operation MUST fail
(error code inconsistentValue)."
View at oid-info.com
The table row may be created with
'createAndWait(5)' or 'createAndGo(4)'.
To activate a connection entry, a valid connection
descriptor MUST be established in the
frAtmIwfConnectionDescriptor object.
This object is set to 'destroy(6)' to delete the
table row. Before the table row is destroyed, the
OperStatus/AdminStatus of the corresponding
endpoints MUST be 'down(2)'. The deactivation of
the ATM endpoint MAY occur as a side-effect of
deleting the FR/ATM IWF cross-connection table
row. Otherwise, 'destroy(6)' operation MUST fail
(error code 'inconsistentValue').
Parsed from file rfc2955-FR-to-ATM-Service-Interworking.mib.txt
Company: None
Module: FR-ATM-PVC-SERVICE-IWF-MIB
The table row may be created with
'createAndWait(5)' or 'createAndGo(4)'.
To activate a connection entry, a valid connection
descriptor MUST be established in the
frAtmIwfConnectionDescriptor object.
This object is set to 'destroy(6)' to delete the
table row. Before the table row is destroyed, the
OperStatus/AdminStatus of the corresponding
endpoints MUST be 'down(2)'. The deactivation of
the ATM endpoint MAY occur as a side-effect of
deleting the FR/ATM IWF cross-connection table
row. Otherwise, 'destroy(6)' operation MUST fail
(error code 'inconsistentValue').
Parsed from file FR-ATM-PVC-SERVICE-IWF-MIB.mib
Module: FR-ATM-PVC-SERVICE-IWF-MIB
Automatically extracted from RFC2955
frAtmIwfConnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The table row may be created with 'createAndWait(5)' or 'createAndGo(4)'. To activate a connection entry, a valid connection descriptor MUST be established in the frAtmIwfConnectionDescriptor object. This object is set to 'destroy(6)' to delete the table row. Before the table row is destroyed, the OperStatus/AdminStatus of the corresponding endpoints MUST be 'down(2)'. The deactivation of the ATM endpoint MAY occur as a side-effect of deleting the FR/ATM IWF cross-connection table row. Otherwise, 'destroy(6)' operation MUST fail (error code 'inconsistentValue')." ::= { frAtmIwfConnectionEntry 7 }
frAtmIwfConnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The table row may be created with 'createAndWait(5)' or 'createAndGo(4)'. To activate a connection entry, a valid connection descriptor MUST be established in the frAtmIwfConnectionDescriptor object. This object is set to 'destroy(6)' to delete the table row. Before the table row is destroyed, the OperStatus/AdminStatus of the corresponding endpoints MUST be 'down(2)'. The deactivation of the ATM endpoint MAY occur as a side-effect of deleting the FR/ATM IWF cross-connection table row. Otherwise, 'destroy(6)' operation MUST fail (error code 'inconsistentValue')." ::= { frAtmIwfConnectionEntry 7 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.86.1.2.1.1 | frAtmIwfConnIndex | 0 | 0 | A unique value for each point-to-point or point- to-multipoint connection. The manager obtains the frAtmIwfConnIndex value by re… |
1.3.6.1.2.1.86.1.2.1.2 | frAtmIwfConnAtmPort | 0 | 0 | The index in the ifTable that identifies the ATM port for this interworking connection. |
1.3.6.1.2.1.86.1.2.1.3 | frAtmIwfConnVpi | 0 | 0 | The VPI of the ATM PVC end point for this interworking connection. |
1.3.6.1.2.1.86.1.2.1.4 | frAtmIwfConnVci | 0 | 0 | The VCI of the ATM PVC end point for this interworking connection. |
1.3.6.1.2.1.86.1.2.1.5 | frAtmIwfConnFrPort | 0 | 0 | The index in the ifTable that identifies the frame relay port for this interworking connection. |
1.3.6.1.2.1.86.1.2.1.6 | frAtmIwfConnDlci | 0 | 0 | The DLCI that identifies the frame relay PVC end point for this interworking connection. |
1.3.6.1.2.1.86.1.2.1.8 | frAtmIwfConnAdminStatus | 0 | 0 | The desired operational state for this FR/ATM interworked connection. up(1) = Activate the connection. Before the activation… |
1.3.6.1.2.1.86.1.2.1.9 | frAtmIwfConnAtm2FrOperStatus | 0 | 0 | The current operational state of this interworking connection in the ATM to frame relay direction. |
1.3.6.1.2.1.86.1.2.1.10 | frAtmIwfConnAtm2FrLastChange | 0 | 0 | The value of sysUpTime at the time this interworking connection entered its current operational state in the ATM to FR direction.… |
1.3.6.1.2.1.86.1.2.1.11 | frAtmIwfConnFr2AtmOperStatus | 0 | 0 | The current operational state of this interworking connection in the frame relay to ATM direction. |
1.3.6.1.2.1.86.1.2.1.12 | frAtmIwfConnFr2AtmLastChange | 0 | 0 | The value of sysUpTime at the time this interworking connection entered its current operational state in the FR to ATM direction.… |
1.3.6.1.2.1.86.1.2.1.13 | frAtmIwfConnectionDescriptor | 0 | 0 | The value represents a pointer to the relevant descriptor in the IWF descriptor table. An attempt to set this value to an inacti… |
1.3.6.1.2.1.86.1.2.1.14 | frAtmIwfConnFailedFrameTranslate | 0 | 0 | This object counts the number of frames discarded by the IWF because, while operating in Translation Mode, the IWF is unable to d… |
1.3.6.1.2.1.86.1.2.1.15 | frAtmIwfConnOverSizedFrames | 0 | 0 | Count of frames discarded by the IWF because the frame is too large to be processed by the AAL5 segmentation procedure. Specific… |
1.3.6.1.2.1.86.1.2.1.16 | frAtmIwfConnFailedAal5PduTranslate | 0 | 0 | This attribute counts the number of AAL5 PDUs discarded by the IWF because, while operating in Translation Mode, the IWF is unabl… |
1.3.6.1.2.1.86.1.2.1.17 | frAtmIwfConnOverSizedSDUs | 0 | 0 | Count of AAL5 SDUs discarded by the IWF because the SDU is too large to be forwarded on the frame relay segment of the connection… |
1.3.6.1.2.1.86.1.2.1.18 | frAtmIwfConnCrcErrors | 0 | 0 | The number of AAL5 CPCS PDUs received with CRC-32 errors on this AAL5 VCC at the IWF. AAL5 PDUs are received in the ATM to frame … |
1.3.6.1.2.1.86.1.2.1.19 | frAtmIwfConnSarTimeOuts | 0 | 0 | The number of partially re-assembled AAL5 CPCS PDUs which were discarded on this AAL5 VCC at the IWF because they were not fully … |