Reference record for OID 1.3.6.1.2.1.97.2.1.2


parent
1.3.6.1.2.1.97.2.1 (diffServMIBCompliances)
node code
2
node name
diffServMIBReadOnlyCompliance
dot oid
1.3.6.1.2.1.97.2.1.2
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) diffServMib(97) diffServMIBConformance(2) diffServMIBCompliances(1) diffServMIBReadOnlyCompliance(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • /iso/identified-organization/dod/internet/mgmt/mib/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib-2/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/diffServMib/diffServMIBConformance/diffServMIBCompliances/diffServMIBReadOnlyCompliance
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/97/2/1/2

    Description by circitor

    When this MIB is implemented without support for read-create
    (i.e. in read-only mode), then such an implementation can claim
    read-only compliance. Such a device can then be monitored but can
    not be configured with this MIB.

    Parsed from file DIFFSERV-MIB.mib
    Module: DIFFSERV-MIB

    Description by oid_info

    diffServMIBReadOnlyCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
    "When this MIB is implemented without support for read-create
    (i.e. in read-only mode), then such an implementation can claim
    read-only compliance. Such a device can then be monitored but can
    not be configured with this MIB."
    MODULE IF-MIB -- The interfaces MIB, RFC2863
    MANDATORY-GROUPS {
    ifCounterDiscontinuityGroup
    }
    MODULE -- This Module
    MANDATORY-GROUPS {
    diffServMIBDataPathGroup, diffServMIBClfrGroup,
    diffServMIBClfrElementGroup, diffServMIBMultiFieldClfrGroup,
    diffServMIBActionGroup, diffServMIBAlgDropGroup,
    diffServMIBQGroup, diffServMIBSchedulerGroup,
    diffServMIBMaxRateGroup, diffServMIBMinRateGroup,
    diffServMIBCounterGroup
    }
    GROUP diffServMIBMeterGroup
    DESCRIPTION
    "This group is mandatory for devices that implement metering
    functions."
    GROUP diffServMIBTBParamGroup
    DESCRIPTION
    "This group is mandatory for devices that implement token-bucket
    metering functions."
    GROUP diffServMIBDscpMarkActGroup
    DESCRIPTION
    "This group is mandatory for devices that implement DSCP-Marking
    functions."
    GROUP diffServMIBRandomDropGroup


    DESCRIPTION
    "This group is mandatory for devices that implement Random Drop
    functions."
    OBJECT diffServDataPathStart
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServDataPathStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServDataPathStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServClfrNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object not needed when diffServClfrTable is implemented read-
    only"
    OBJECT diffServClfrStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServClfrStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServClfrElementNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object not needed when diffServClfrelementTable is implemented
    read-only"
    OBJECT diffServClfrElementPrecedence
    MIN-ACCESS read-only
    DESCRIPTION


    "Write access is not required."
    OBJECT diffServClfrElementNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServClfrElementSpecific
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServClfrElementStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServClfrElementStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServMultiFieldClfrNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServMultiFieldClfrTable is
    implemented in read-only mode."
    OBJECT diffServMultiFieldClfrAddrType
    SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. An implementation is only required
    to support IPv4 and IPv6 addresses."
    OBJECT diffServMultiFieldClfrDstAddr
    SYNTAX InetAddress (SIZE(0|4|16))
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. An implementation is only required
    to support IPv4 and globally unique IPv6 addresses."
    OBJECT diffServMultiFieldClfrDstPrefixLength
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."


    OBJECT diffServMultiFieldClfrSrcAddr
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required. An implementation is only required
    to support IPv4 and globally unique IPv6 addresses."
    OBJECT diffServMultiFieldClfrSrcPrefixLength
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrDscp
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrFlowId
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrProtocol
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrDstL4PortMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrDstL4PortMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrSrcL4PortMin
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrSrcL4PortMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrStorage
    MIN-ACCESS read-only


    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMultiFieldClfrStatus
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, createAndWait and notInService
    support is not required."
    OBJECT diffServMeterNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServMultiFieldClfrTable is
    implemented in read-only mode."
    OBJECT diffServMeterSucceedNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMeterFailNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMeterSpecific
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMeterStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMeterStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServTBParamNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServTBParamTable is implemented in
    read-only mode."


    OBJECT diffServTBParamType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServTBParamRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServTBParamBurstSize
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServTBParamInterval
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServTBParamStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServTBParamStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServActionNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServActionTable is implemented in
    read-only mode."
    OBJECT diffServActionInterface
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServActionNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."


    OBJECT diffServActionSpecific
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServActionStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServActionStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServCountActNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServCountActTable is implemented
    in read-only mode."
    OBJECT diffServCountActStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServCountActStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServAlgDropNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServAlgDropTable is implemented in
    read-only mode."
    OBJECT diffServAlgDropType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropNext
    MIN-ACCESS read-only


    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropQMeasure
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropQThreshold
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropSpecific
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServAlgDropStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServRandomDropNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServRandomDropTable is implemented
    in read-only mode."
    OBJECT diffServRandomDropMinThreshBytes
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropMinThreshPkts
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropMaxThreshBytes
    MIN-ACCESS read-only


    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropMaxThreshPkts
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropProbMax
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropWeight
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropSamplingRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServRandomDropStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServQNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServQTable is implemented in
    read-only mode."
    OBJECT diffServQNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServQMinRate
    MIN-ACCESS read-only


    DESCRIPTION
    "Write access is not required."
    OBJECT diffServQMaxRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServQStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServQStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServSchedulerNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServSchedulerTable is implemented
    in read-only mode."
    OBJECT diffServSchedulerNext
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServSchedulerMethod
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServSchedulerMinRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServSchedulerMaxRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServSchedulerStorage
    MIN-ACCESS read-only


    DESCRIPTION
    "Write access is not required."
    OBJECT diffServSchedulerStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServMinRateNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServMinRateTable is implemented in
    read-only mode."
    OBJECT diffServMinRatePriority
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMinRateAbsolute
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMinRateRelative
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMinRateStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMinRateStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."
    OBJECT diffServMaxRateNextFree
    MIN-ACCESS not-accessible
    DESCRIPTION
    "Object is not needed when diffServMaxrateTable is implemented in
    read-only mode."


    OBJECT diffServMaxRateAbsolute
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMaxRateRelative
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMaxRateThreshold
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMaxRateStorage
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT diffServMaxRateStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required, and active is the only status that
    needs to be supported."

    View at oid-info.com

    Description by mibdepot

    When this MIB is implemented without support for read-create
    (i.e. in read-only mode), then such an implementation can claim
    read-only compliance. Such a device can then be monitored but can
    not be configured with this MIB.

    Parsed from file diffserv.mib.txt
    Company: None
    Module: DIFFSERV-MIB

    Description by cisco

    When this MIB is implemented without support for read-create
    (i.e. in read-only mode), then such an implementation can claim
    read-only compliance. Such a device can then be monitored but can
    not be configured with this MIB.

    Information by circitor

    diffServMIBReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB is implemented without support for read-create (i.e. in read-only mode), then such an implementation can claim read-only compliance. Such a device can then be monitored but can not be configured with this MIB." MODULE IF-MIB MANDATORY-GROUPS { ifCounterDiscontinuityGroup } MODULE MANDATORY-GROUPS { diffServMIBDataPathGroup, diffServMIBClfrGroup, diffServMIBClfrElementGroup, diffServMIBMultiFieldClfrGroup, diffServMIBActionGroup, diffServMIBAlgDropGroup, diffServMIBQGroup, diffServMIBSchedulerGroup, diffServMIBMaxRateGroup, diffServMIBMinRateGroup, diffServMIBCounterGroup } GROUP diffServMIBMeterGroup DESCRIPTION "This group is mandatory for devices that implement metering functions." GROUP diffServMIBTBParamGroup DESCRIPTION "This group is mandatory for devices that implement token-bucket metering functions." GROUP diffServMIBDscpMarkActGroup DESCRIPTION "This group is mandatory for devices that implement DSCP-Marking functions." GROUP diffServMIBRandomDropGroup DESCRIPTION "This group is mandatory for devices that implement Random Drop functions." OBJECT diffServDataPathStart MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrTable is implemented read- only" OBJECT diffServClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrElementNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrelementTable is implemented read-only" OBJECT diffServClfrElementPrecedence MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMultiFieldClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMultiFieldClfrAddrType SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and IPv6 addresses." OBJECT diffServMultiFieldClfrDstAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrDstPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcAddr MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrSrcPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDscp MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrFlowId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrProtocol MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required, createAndWait and notInService support is not required." OBJECT diffServMeterNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMeterSucceedNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterFailNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServTBParamNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServTBParamTable is implemented in read-only mode." OBJECT diffServTBParamType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServActionNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServActionTable is implemented in read-only mode." OBJECT diffServActionInterface MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServCountActNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServCountActTable is implemented in read-only mode." OBJECT diffServCountActStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServCountActStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServAlgDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServAlgDropTable is implemented in read-only mode." OBJECT diffServAlgDropType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQMeasure MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServRandomDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServRandomDropTable is implemented in read-only mode." OBJECT diffServRandomDropMinThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMinThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropProbMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropWeight MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropSamplingRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServQNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServQTable is implemented in read-only mode." OBJECT diffServQNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServSchedulerNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServSchedulerTable is implemented in read-only mode." OBJECT diffServSchedulerNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMethod MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMinRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMinRateTable is implemented in read-only mode." OBJECT diffServMinRatePriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMaxRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMaxrateTable is implemented in read-only mode." OBJECT diffServMaxRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." ::= { diffServMIBCompliances 2 }

    Information by cisco_v1

    diffServMIBReadOnlyCompliance OBJECT IDENTIFIER ::= { diffServMIBCompliances 2 }

    Information by oid_info

    Automatically extracted from RFC3289

    Information by mibdepot

    diffServMIBReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB is implemented without support for read-create (i.e. in read-only mode), then such an implementation can claim read-only compliance. Such a device can then be monitored but can not be configured with this MIB." MODULE IF-MIB MANDATORY-GROUPS { ifCounterDiscontinuityGroup } MODULE MANDATORY-GROUPS { diffServMIBDataPathGroup, diffServMIBClfrGroup, diffServMIBClfrElementGroup, diffServMIBMultiFieldClfrGroup, diffServMIBActionGroup, diffServMIBAlgDropGroup, diffServMIBQGroup, diffServMIBSchedulerGroup, diffServMIBMaxRateGroup, diffServMIBMinRateGroup, diffServMIBCounterGroup } GROUP diffServMIBMeterGroup DESCRIPTION "This group is mandatory for devices that implement metering functions." GROUP diffServMIBTBParamGroup DESCRIPTION "This group is mandatory for devices that implement token-bucket metering functions." GROUP diffServMIBDscpMarkActGroup DESCRIPTION "This group is mandatory for devices that implement DSCP-Marking functions." GROUP diffServMIBRandomDropGroup DESCRIPTION "This group is mandatory for devices that implement Random Drop functions." OBJECT diffServDataPathStart MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrTable is implemented read- only" OBJECT diffServClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrElementNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrelementTable is implemented read-only" OBJECT diffServClfrElementPrecedence MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMultiFieldClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMultiFieldClfrAddrType SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and IPv6 addresses." OBJECT diffServMultiFieldClfrDstAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrDstPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcAddr MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrSrcPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDscp MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrFlowId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrProtocol MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required, createAndWait and notInService support is not required." OBJECT diffServMeterNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMeterSucceedNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterFailNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServTBParamNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServTBParamTable is implemented in read-only mode." OBJECT diffServTBParamType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServActionNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServActionTable is implemented in read-only mode." OBJECT diffServActionInterface MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServCountActNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServCountActTable is implemented in read-only mode." OBJECT diffServCountActStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServCountActStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServAlgDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServAlgDropTable is implemented in read-only mode." OBJECT diffServAlgDropType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQMeasure MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServRandomDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServRandomDropTable is implemented in read-only mode." OBJECT diffServRandomDropMinThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMinThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropProbMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropWeight MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropSamplingRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServQNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServQTable is implemented in read-only mode." OBJECT diffServQNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServSchedulerNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServSchedulerTable is implemented in read-only mode." OBJECT diffServSchedulerNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMethod MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMinRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMinRateTable is implemented in read-only mode." OBJECT diffServMinRatePriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMaxRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMaxrateTable is implemented in read-only mode." OBJECT diffServMaxRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." ::= { diffServMIBCompliances 2 }

    Information by cisco

    diffServMIBReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB is implemented without support for read-create (i.e. in read-only mode), then such an implementation can claim read-only compliance. Such a device can then be monitored but can not be configured with this MIB." MODULE IF-MIB MANDATORY-GROUPS { ifCounterDiscontinuityGroup } MODULE MANDATORY-GROUPS { diffServMIBDataPathGroup, diffServMIBClfrGroup, diffServMIBClfrElementGroup, diffServMIBMultiFieldClfrGroup, diffServMIBActionGroup, diffServMIBAlgDropGroup, diffServMIBQGroup, diffServMIBSchedulerGroup, diffServMIBMaxRateGroup, diffServMIBMinRateGroup, diffServMIBCounterGroup } GROUP diffServMIBMeterGroup DESCRIPTION "This group is mandatory for devices that implement metering functions." GROUP diffServMIBTBParamGroup DESCRIPTION "This group is mandatory for devices that implement token-bucket metering functions." GROUP diffServMIBDscpMarkActGroup DESCRIPTION "This group is mandatory for devices that implement DSCP-Marking functions." GROUP diffServMIBRandomDropGroup DESCRIPTION "This group is mandatory for devices that implement Random Drop functions." OBJECT diffServDataPathStart MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServDataPathStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrTable is implemented read- only" OBJECT diffServClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServClfrElementNextFree MIN-ACCESS not-accessible DESCRIPTION "Object not needed when diffServClfrelementTable is implemented read-only" OBJECT diffServClfrElementPrecedence MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServClfrElementStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMultiFieldClfrNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMultiFieldClfrAddrType SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2) } MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and IPv6 addresses." OBJECT diffServMultiFieldClfrDstAddr SYNTAX InetAddress (SIZE(0|4|16)) MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrDstPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcAddr MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation is only required to support IPv4 and globally unique IPv6 addresses." OBJECT diffServMultiFieldClfrSrcPrefixLength MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDscp MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrFlowId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrProtocol MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrDstL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMin MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrSrcL4PortMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMultiFieldClfrStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required, createAndWait and notInService support is not required." OBJECT diffServMeterNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMultiFieldClfrTable is implemented in read-only mode." OBJECT diffServMeterSucceedNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterFailNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMeterStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServTBParamNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServTBParamTable is implemented in read-only mode." OBJECT diffServTBParamType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamInterval MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServTBParamStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServActionNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServActionTable is implemented in read-only mode." OBJECT diffServActionInterface MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServActionStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServCountActNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServCountActTable is implemented in read-only mode." OBJECT diffServCountActStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServCountActStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServAlgDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServAlgDropTable is implemented in read-only mode." OBJECT diffServAlgDropType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQMeasure MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropQThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropSpecific MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServAlgDropStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServRandomDropNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServRandomDropTable is implemented in read-only mode." OBJECT diffServRandomDropMinThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMinThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropMaxThreshPkts MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropProbMax MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropWeight MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropSamplingRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServRandomDropStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServQNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServQTable is implemented in read-only mode." OBJECT diffServQNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServQStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServSchedulerNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServSchedulerTable is implemented in read-only mode." OBJECT diffServSchedulerNext MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMethod MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMinRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServSchedulerStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMinRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMinRateTable is implemented in read-only mode." OBJECT diffServMinRatePriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMinRateStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." OBJECT diffServMaxRateNextFree MIN-ACCESS not-accessible DESCRIPTION "Object is not needed when diffServMaxrateTable is implemented in read-only mode." OBJECT diffServMaxRateAbsolute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateRelative MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStorage MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT diffServMaxRateStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and active is the only status that needs to be supported." ::= { diffServMIBCompliances 2 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.97.2.1.1 diffServMIBFullCompliance 0 0 When this MIB is implemented with support for read-create, then
    such an implementation can claim full compliance. Such devices
    ca…