This object returns information about the previous policy
script executions.
If the actionSkippedDueToPrecedence(1) bit is set, the last
execution of the associated policy condition returned non-zero,
but the action is not active, because it was trumped by a
matching policy condition in the same precedence group with a
higher precedence value.
If the conditionRunTimeException(2) bit is set, the last
execution of the associated policy condition encountered a
run-time exception and aborted.
If the conditionUserSignal(3) bit is set, the last
execution of the associated policy condition called the
signalError() function.
If the actionRunTimeException(4) bit is set, the last
execution of the associated policy action encountered a
run-time exception and aborted.
If the actionUserSignal(5) bit is set, the last
execution of the associated policy action called the
signalError() function.
Entries will only exist in this table of one or more bits are
set. In particular, if an entry does not exist for a
particular policy/element combination, it can be assumed that
the policy's condition did not match 'this element'.
Parsed from file rfc4011-Policy-Based-Management.mib.txt
Company: ietf_rfcs
Module: POLICY-BASED-MANAGEMENT-MIB
pmTrackingPEInfo OBJECT-TYPE SYNTAX BITS { actionSkippedDueToPrecedence(0), conditionRunTimeException(1), conditionUserSignal(2), actionRunTimeException(3), actionUserSignal(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns information about the previous policy script executions. If the actionSkippedDueToPrecedence(1) bit is set, the last execution of the associated policy condition returned non-zero, but the action is not active, because it was trumped by a matching policy condition in the same precedence group with a higher precedence value. If the conditionRunTimeException(2) bit is set, the last execution of the associated policy condition encountered a run-time exception and aborted. If the conditionUserSignal(3) bit is set, the last execution of the associated policy condition called the signalError() function. If the actionRunTimeException(4) bit is set, the last execution of the associated policy action encountered a run-time exception and aborted. If the actionUserSignal(5) bit is set, the last execution of the associated policy action called the signalError() function. Entries will only exist in this table of one or more bits are set. In particular, if an entry does not exist for a particular policy/element combination, it can be assumed that the policy's condition did not match 'this element'." ::= { pmTrackingPEEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.3.107.9.1.1 | pmTrackingPolicyToElementElement, pmTrackingPEElement | 0 | 0 | The element that is configured by the associated policy. |
1.3.6.1.3.107.9.1.2 | pmTrackingPolicyToElementInfo, pmTrackingPEContextName | 0 | 0 | This object returns information about the previous policy script executions. If the filterMatched(0) bit is set, the last executi… |
1.3.6.1.3.107.9.1.3 | pmTrackingPEContextEngineID | 0 | 0 | If the associated element is on a remote system, this object is used to identify the remote system. This object contains the con… |