Reference record for OID 1.3.6.1.3.29.2.3.1.1.9


parent
1.3.6.1.3.29.2.3.1.1 (rptrMonitorPortEntry)
node code
9
node name
rptrMonitorPortRunts
dot oid
1.3.6.1.3.29.2.3.1.1.9
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) experimental(3) hubmib(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) experimental(3) snmpDot3RptrMgt(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • {iso(1) org(3) dod(6) internet(1) experimental(3) hubmib(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • {iso(1) org(3) dod(6) internet(1) experimental(3) snmpDot3RptrMgt(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) experimental(3) hubmib(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) experimental(3) snmpDot3RptrMgt(29) rptrMonitorPackage(2) rptrMonitorPortInfo(3) rptrMonitorPortTable(1) rptrMonitorPortEntry(1) rptrMonitorPortRunts(9)}
  • iri oid
  • /iso/identified-organization/dod/internet/experimental/hubmib/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • /iso/identified-organization/dod/internet/experimental/snmpDot3RptrMgt/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • /iso/org/dod/internet/experimental/hubmib/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • /iso/org/dod/internet/experimental/snmpDot3RptrMgt/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • /iso/iso-identified-organization/dod/internet/experimental/hubmib/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • /iso/iso-identified-organization/dod/internet/experimental/snmpDot3RptrMgt/rptrMonitorPackage/rptrMonitorPortInfo/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonitorPortRunts
  • Description by cisco_v1

    This counter is incremented by one for each
    CarrierEvent on this port that meets one of the
    following two conditions. Only one test need be
    made. a) The ActivityDuration is greater than
    ShortEventMaxTime and less than ValidPacketMinTime
    and the CollisionEvent signal is deasserted. b)
    The OctetCount is less than 64, the
    ActivityDuration is greater than ShortEventMaxTime
    and the CollisionEvent signal is deasserted.
    ValidPacketMinTime is greater than or equal to 552
    bit times and less than 565 bit times.

    An event whose length is greater than 74 bit times
    but less than 82 bit times shall increment either
    the shortEvents counter or the runts counter but
    not both. A CarrierEvent greater than or equal to
    552 bit times but less than 565 bit times may or
    may not be counted as a runt.

    ValidPacketMinTime has tolerances included to
    provide for circuit losses between a conformance
    test point at the AUI and the measurement point
    within the state machine.

    Runts usually indicate collision fragments, a
    normal network event. In certain situations
    associated with large diameter networks a
    percentage of collision fragments may exceed
    ValidPacketMinTime.

    The approximate minimum time for rollover of this
    counter is 16 hours.

    Description by mibdepot

    This counter is incremented by one for each
    CarrierEvent on this port that meets one of the
    following two conditions. Only one test need be
    made. a) The ActivityDuration is greater than
    ShortEventMaxTime and less than ValidPacketMinTime
    and the CollisionEvent signal is deasserted. b)
    The OctetCount is less than 64, the
    ActivityDuration is greater than ShortEventMaxTime
    and the CollisionEvent signal is deasserted.
    ValidPacketMinTime is greater than or equal to 552
    bit times and less than 565 bit times.

    An event whose length is greater than 74 bit times
    but less than 82 bit times shall increment either
    the shortEvents counter or the runts counter but
    not both. A CarrierEvent greater than or equal to
    552 bit times but less than 565 bit times may or
    may not be counted as a runt.

    ValidPacketMinTime has tolerances included to
    provide for circuit losses between a conformance
    test point at the AUI and the measurement point
    within the state machine.

    Runts usually indicate collision fragments, a
    normal network event. In certain situations
    associated with large diameter networks a
    percentage of collision fragments may exceed
    ValidPacketMinTime.

    The approximate minimum time for rollover of this
    counter is 16 hours.

    Parsed from file rfc1516.mib.txt
    Company: None
    Module: RFC1516-MIB

    Description by circitor

    This counter is incremented by one for each
    CarrierEvent on this port that meets one of the
    following two conditions. Only one test need be
    made. a) The ActivityDuration is greater than
    ShortEventMaxTime and less than ValidPacketMinTime
    and the CollisionEvent signal is deasserted. b)
    The OctetCount is less than 64, the
    ActivityDuration is greater than ShortEventMaxTime
    and the CollisionEvent signal is deasserted.
    ValidPacketMinTime is greater than or equal to 552
    bit times and less than 565 bit times.

    An event whose length is greater than 74 bit times
    but less than 82 bit times shall increment either
    the shortEvents counter or the runts counter but
    not both. A CarrierEvent greater than or equal to
    552 bit times but less than 565 bit times may or
    may not be counted as a runt.

    ValidPacketMinTime has tolerances included to
    provide for circuit losses between a conformance
    test point at the AUI and the measurement point
    within the state machine.

    Runts usually indicate collision fragments, a
    normal network event. In certain situations
    associated with large diameter networks a
    percentage of collision fragments may exceed
    ValidPacketMinTime.

    The approximate minimum time for rollover of this
    counter is 16 hours.

    Parsed from file ITOUCHHUB.mib
    Module: ITOUCHHUB

    Information by cisco_v1

    rptrMonitorPortRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts." ::= { rptrMonitorPortEntry 9 }

    Information by mibdepot

    rptrMonitorPortRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts." ::= { rptrMonitorPortEntry 9 }

    Information by circitor

    rptrMonitorPortRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts." ::= { rptrMonitorPortEntry 9 }

    First Registration Authority (recovered by parent 1.3.6.1.3.29)

    McMaster Donna

    Current Registration Authority (recovered by parent 1.3.6.1.3)

    Internet Assigned Numbers Authority

    Brothers (15)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.3.29.2.3.1.1.1 rptrMonitorPortGroupIndex 0 0 This object identifies the group containing the
    port for which this entry contains information.
    1.3.6.1.3.29.2.3.1.1.2 rptrMonitorPortIndex 0 0 This object identifies the port within the group
    for which this entry contains information.
    1.3.6.1.3.29.2.3.1.1.3 rptrMonitorPortReadableFrames 0 0 This object is the number of frames of valid
    frame length that have been received on this port.
    This counter is incremented by on…
    1.3.6.1.3.29.2.3.1.1.4 rptrMonitorPortReadableOctets 0 0 This object is the number of octets contained in
    valid frames that have been received on this port.
    This counter is incremented b…
    1.3.6.1.3.29.2.3.1.1.5 rptrMonitorPortFCSErrors 0 0 This counter is incremented by one for each frame
    received on this port with the FCSError signal
    asserted and the FramingError an…
    1.3.6.1.3.29.2.3.1.1.6 rptrMonitorPortAlignmentErrors 0 0 This counter is incremented by one for each frame
    received on this port with the FCSError and
    FramingError signals asserted and C…
    1.3.6.1.3.29.2.3.1.1.7 rptrMonitorPortFrameTooLongs 0 0 This counter is incremented by one for each frame
    received on this port whose OctetCount is greater
    than maxFrameSize (Ref: 4.4.2…
    1.3.6.1.3.29.2.3.1.1.8 rptrMonitorPortShortEvents 0 0 This counter is incremented by one for each
    CarrierEvent on this port with ActivityDuration
    less than ShortEventMaxTime. ShortEv…
    1.3.6.1.3.29.2.3.1.1.10 rptrMonitorPortCollisions 0 0 This counter is incremented by one for any
    CarrierEvent signal on any port for which the
    CollisionEvent signal on this port is al…
    1.3.6.1.3.29.2.3.1.1.11 rptrMonitorPortLateEvents 0 0 This counter is incremented by one for each
    CarrierEvent on this port in which the CollIn(X)
    variable transitions to the value SQ…
    1.3.6.1.3.29.2.3.1.1.12 rptrMonitorPortVeryLongEvents 0 0 This counter is incremented by one for each
    CarrierEvent on this port whose ActivityDuration
    is greater than the MAU Jabber Locku…
    1.3.6.1.3.29.2.3.1.1.13 rptrMonitorPortDataRateMismatches 0 0 This counter is incremented by one for each frame
    received on this port that meets all of the
    following conditions: a) The Colli…
    1.3.6.1.3.29.2.3.1.1.14 rptrMonitorPortAutoPartitions 0 0 This counter is incremented by one for each time
    the repeater has automatically partitioned this
    port. The conditions that cause…
    1.3.6.1.3.29.2.3.1.1.15 rptrMonitorPortTotalErrors 0 0 The total number of errors which have occurred on
    this port. This counter is the summation of the
    values of other error counters…
    1.3.6.1.3.29.2.3.1.1.16 rptrMonitorPortLastChange 0 0 The value of sysUpTime when the last of
    the following occurred:
    1) the agent cold- or warm-started;
    2) the row for the port was cr…