Description 1
If true, suppress normal transmission of and interpretation of Intra-domain ISIS PDUs on this circuit.
Sources for this description
D-Link official switch MIBsFS.COM official Documentation Hub native MIB packagesMIBdepot
OID reference
1.3.6.1.3.37.1.3.1.1.7
If true, suppress normal transmission of and interpretation of Intra-domain ISIS PDUs on this circuit.
Identification
{1 3 6 1 3 37 1 3 1 1 7}
Definitions may combine these properties differently.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The FS.COM catalogue lists MIB packages containing this definition for these models:
N5860-48SC, N8560-32C, N8560-48BC, N8560-64C, NC8200-16Q, NC8200-24BC, NC8200-4TD, NC8200-8C, NC8400-16CD, NC8400-32C, NC8400-4TH, S3100-16TF.
S3410-24TS-P, S3910-24TS, S3910-48TS, S5810-28FS, S5810-28TS, S5810-48FS, S5810-48TS, S5810-48TS-P, S5860-20SQ, S5860-24XB-U, S5860-48SC.
A definition in a model's MIB package does not establish that the device implements it or permits access.
Available source records contain 4 distinct definitions; some records may not include a definition.
isisCircExtDomain OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If true, suppress normal transmission of and
interpretation of Intra-domain ISIS PDUs on this
circuit."
REFERENCE "{ISIS.aoi externalDomain (46)}"
DEFVAL { false }
::= { isisCircEntry 7 }isisCircLevelHelloMultiplier OBJECT-TYPE
SYNTAX Integer32 (2..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value is multiplied by the corresponding HelloTimer
and the result in seconds (rounded up) is used as the
holding time in transmitted hellos, to be used by receivers
of hello packets from this IS"
REFERENCE "ISIS.aoi iSISHelloTimer (45)"
DEFVAL { 10 }
::= { isisCircLevelEntry 7 }isisCircLevelHelloTimer OBJECT-TYPE
SYNTAX Integer32 (10..600000)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum period, in milliseconds, between IIH PDUs
on multiaccess networks at this level for LANs.
The value at level 1 is used as the period between
Hellos on point to point circuits. Setting this
value at level 2 on a point to point circuit will
result in an error of InconsistentValue.
This object follows the resettingTimer behavior."
REFERENCE "{ISIS.aoi iSISHelloTimer (45)}"
DEFVAL { 3000 }
::= { isisCircLevelEntry 7 }isisCircExtDomain OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If true, suppress normal transmission of and
interpretation of Intra-domain IS-IS PDUs on this
circuit."
REFERENCE "{ISIS.aoi externalDomain (46)}"
DEFVAL { false }
::= { isisCircEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
If true, suppress normal transmission of and interpretation of Intra-domain ISIS PDUs on this circuit.
D-Link official switch MIBsFS.COM official Documentation Hub native MIB packagesMIBdepot
Description 2
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Implementation notes: Currently, the maximum access is read-only.
Huawei official enterprise MIB Query and object descriptions
Description 3
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Implementation notes: The actually supported access is read-only.
Huawei official enterprise MIB Query and object descriptions
Description 4
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Implementation notes: The actually supported access is read-createread-only
Huawei official enterprise MIB Query and object descriptions
Description 5
This value is multiplied by the corresponding HelloTimer and the result in seconds (rounded up) is used as the holding time in transmitted hellos, to be used by receivers of hello packets from this IS
Nokia networking MIB copies (LibreNMS/Observium Community)
Description 6
Maximum period, in milliseconds, between IIH PDUs on multiaccess networks at this level for LANs. The value at level 1 is used as the period between Hellos on point to point circuits. Setting this value at level 2 on a point to point circuit will result in an error of InconsistentValue. This object follows the resettingTimer behavior.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Belden, GarrettCom and Hirschmann IT official standalone MIBs
Description 7
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Implementation notes: The actually supported access is read-only
Huawei official enterprise MIB Query and object descriptions
Description 8
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Huawei MIB copies (LibreNMS/Observium Community)MIBdepot
Description 9
If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.
Implementation notes: The actually supported access is read-create
Huawei official enterprise MIB Query and object descriptions
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: isisCircExtDomain
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"isisCircExtDomain",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"If true, suppress normal transmission of and interpretation of Intra-domain ISIS PDUs on this circuit.\"",
"REFERENCE",
"\"{ISIS.aoi externalDomain (46)}\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"isisCircEntry",
"7",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"If true, suppress normal transmission of and interpretation of Intra-domain ISIS PDUs on this circuit."
],
[
"REFERENCE",
"{ISIS.aoi externalDomain (46)}"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}Module: ISIS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'experimental', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Module: ISIS-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'experimental', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Related source files and packages:
Same file in 3610.zip.
Same file in 3610.zip.
Same file in 3610.zip.
Same file in 3610-MIB.rar.
Module: ISIS-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'experimental', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Related source files and packages:
Same file in s3100-16tf-switch-snmp-mib-files.zip.
Same file in s5860-series-swithes-snmp-mib-files.zip.
Same file in s3910-series-swithes-snmp-mib-files.zip.
Same file in s3410-series-swithes-snmp-mib-files.zip.
Description 2 · Description 3 · Description 4 · Description 7 · Description 8 · Description 9
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{true(1),false(2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "Currently, the maximum access is read-only."
}Module: ISIS-MIB
· Download Huawei MIB Query — ISIS-MIB (derived data index)Related source files and packages:
Browse all related files for Huawei MIB Query — ISIS-MIB (derived data index)
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{(true,1),(false,2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "The actually supported access is read-only."
}Module: ISIS-MIB
Related source files and packages:
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{true(1),false(2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "The actually supported access is read-createread-only"
}Module: ISIS-MIB
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "TruthValue",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "Currently, the maximum access is read-only."
}Module: ISIS-MIB
Related source files and packages:
Browse all related files for Huawei MIB Query — ISIS-MIB (derived data index)
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{true(1),false(2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "The actually supported access is read-only"
}Module: ISIS-MIB
Related source files and packages:
Browse all related files for Huawei MIB Query — ISIS-MIB (derived data index)
Status in source: current.
Names: isisCircExtDomain
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"isisCircExtDomain",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit.\"",
"REFERENCE",
"\"{ISIS.aoi externalDomain (46)}\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"isisCircEntry",
"7",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"If true, suppress normal transmission of and interpretation of Intra-domain IS-IS PDUs on this circuit."
],
[
"REFERENCE",
"{ISIS.aoi externalDomain (46)}"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}Module: ISIS-MIB
See published definition above
{'IF-MIB': ['ifName'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'experimental', 'TimeTicks'], 'RFC1213-MIB': ['ifEntry', 'ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength'], 'HUAWEI-ISIS-CONF-MIB': ['hwIsisAdjChangeReason']}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: ISIS-MIB
{'IF-MIB': ['ifName'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'experimental', 'TimeTicks'], 'RFC1213-MIB': ['ifEntry', 'ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{true(1),false(2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "The actually supported access is read-create"
}Module: ISIS-MIB
Related source files and packages:
Browse all related files for Huawei MIB Query — ISIS-MIB (derived data index)
Status in source: unspecified.
Names: isisCircExtDomain
{
"syntax": "INTEGER{true(1),false(2)}",
"max_access": "read-create",
"object_class": "table column",
"implementation_notes": "The actually supported access is read-only."
}Module: ISIS-MIB
Related source files and packages:
Browse all related files for Huawei MIB Query — ISIS-MIB (derived data index)
Status in source: current.
Names: isisCircLevelHelloMultiplier
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"isisCircLevelHelloMultiplier",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"2",
".",
".",
"100",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This value is multiplied by the corresponding HelloTimer and the result in seconds (rounded up) is used as the holding time in transmitted hellos, to be used by receivers of hello packets from this IS\"",
"REFERENCE",
"\"ISIS.aoi iSISHelloTimer (45)\"",
"DEFVAL",
"{",
"10",
"}",
"::=",
"{",
"isisCircLevelEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
2,
100
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This value is multiplied by the corresponding HelloTimer and the result in seconds (rounded up) is used as the holding time in transmitted hellos, to be used by receivers of hello packets from this IS"
],
[
"REFERENCE",
"ISIS.aoi iSISHelloTimer (45)"
],
null,
null,
[
"DEFVAL",
10
]
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: ISIS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Counter32', 'experimental'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Related source files and packages:
Status in source: current.
Names: isisCircLevelHelloTimer
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"isisCircLevelHelloTimer",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"10",
".",
".",
"600000",
")",
"UNITS",
[
"literal",
"226d696c6c697365636f6e647322"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"Maximum period, in milliseconds, between IIH PDUs on multiaccess networks at this level for LANs. The value at level 1 is used as the period between Hellos on point to point circuits. Setting this value at level 2 on a point to point circuit will result in an error of InconsistentValue. This object follows the resettingTimer behavior.\"",
"REFERENCE",
"\"{ISIS.aoi iSISHelloTimer (45)}\"",
"DEFVAL",
"{",
"3000",
"}",
"::=",
"{",
"isisCircLevelEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
10,
600000
]
]
]
],
[
"UNITS",
"milliseconds"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Maximum period, in milliseconds, between IIH PDUs on multiaccess networks at this level for LANs. The value at level 1 is used as the period between Hellos on point to point circuits. Setting this value at level 2 on a point to point circuit will result in an error of InconsistentValue. This object follows the resettingTimer behavior."
],
[
"REFERENCE",
"{ISIS.aoi iSISHelloTimer (45)}"
],
null,
null,
[
"DEFVAL",
3000
]
]
}Vendor MIB copy from the Observium Community archive.
Module: ISIS-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'experimental'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Module: ISIS-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'experimental'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Related source files and packages:
Historical records
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.3.37.1.3.1.1.1 | isisCircIndex, isisCircLevelIndex | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.2 | isisCircIfIndex, isisCircLevelDefaultMetric, isisCircLevelMetric | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.3 | isisCircIfSubIndex, isisCircLevelISPriority | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.4 | isisCircAdminState, isisCircLevelCircID, isisCircLevelDesIS | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.5 | isisCircExistState, isisCircLevelDesIS, isisCircLevelLANDesISChanges | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.6 | isisCircType, isisCircLevelLANDesISChanges, isisCircLevelHelloMultiplier | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.8 | isisCircLevel, isisCircLevelHelloTimer, isisCircLevelDRHelloTimer | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.9 | isisCircPassiveCircuit, isisCircLevelDRHelloTimer, isisCircLevelLSPThrottle | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.10 | isisCircMeshGroupEnabled, isisCircLevelLSPThrottle, isisCircLevelMinLSPRetransInt | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.11 | isisCircMeshGroup, isisCircLevelMinLSPRetransInt, isisCircLevelCSNPInterval | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.12 | isisCircSmallHellos, isisCircLevelCSNPInterval, isisCircLevelPartSNPInterval | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.13 | isisCircLastUpTime, isisCircLevelPartSNPInterval | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.14 | isisCirc3WayEnabled | 0 | 0 | |
| 1.3.6.1.3.37.1.3.1.1.15 | isisCircExtendedCircID | 0 | 0 |