Reference record for OID 1.3.6.1.3.95.4.2.1


parent
1.3.6.1.3.95.4.2 (mplsTeCompliances)
node code
1
node name
mplsTeModuleCompliance
dot oid
1.3.6.1.3.95.4.2.1
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) experimental(3) mplsTeMIB(95) mplsTeConformance(4) mplsTeCompliances(2) mplsTeModuleCompliance(1)}
  • {iso(1) org(3) dod(6) internet(1) experimental(3) mplsTeMIB(95) mplsTeConformance(4) mplsTeCompliances(2) mplsTeModuleCompliance(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) experimental(3) mplsTeMIB(95) mplsTeConformance(4) mplsTeCompliances(2) mplsTeModuleCompliance(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/experimental/mplsTeMIB/mplsTeConformance/mplsTeCompliances/mplsTeModuleCompliance
  • /iso/org/dod/internet/experimental/mplsTeMIB/mplsTeConformance/mplsTeCompliances/mplsTeModuleCompliance
  • /iso/iso-identified-organization/dod/internet/experimental/mplsTeMIB/mplsTeConformance/mplsTeCompliances/mplsTeModuleCompliance
  • iri by oid_info
    /ISO/Identified-Organization/6/1/3/95/4/2/1

    Description by oid_info

    mplsTeModuleCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
    "Compliance statement for agents that support the
    MPLS TE MIB."
    MODULE -- this module
    -- The mandatory group has to be implemented by all
    -- LSRs that originate/terminate ESLSPs/tunnels.
    -- In addition, depending on the type of tunnels
    -- supported, other groups become mandatory as
    -- explained below.
    MANDATORY-GROUPS { mplsTunnelGroup,
    mplsTunnelScalarGroup
    }
    GROUP mplsTunnelManualGroup
    DESCRIPTION
    "This group is mandatory for devices which support
    manual configuration of tunnels, in addition to
    mplsTunnelGroup. The following constraints apply:
    mplsTunnelSignallingProto should be at least read-
    only with a value of none(1)."
    GROUP mplsTunnelSignaledGroup
    DESCRIPTION
    "This group is mandatory for devices which support
    signaled tunnel set up, in addition to
    mplsTunnelGroup. The following constraints apply:
    mplsTunnelSignallingProto should be at least read-
    only returning a value of ldp(2), or rsvp(3)."
    GROUP mplsTunnelIsNotIntfcGroup
    DESCRIPTION
    "This group is mandatory for devices which support
    tunnels that are not interfaces, in addition to
    mplsTunnelGroup. The following constraints apply:
    mplsTunnelIsIf must at least be read-only
    returning false(1)."
    GROUP mplsTunnelIsIntfcGroup
    DESCRIPTION
    "This group is mandatory for devices which support
    tunnels that are interfaces, in addition to
    mplsTunnelGroup. The following constraints apply:
    mplsTunnelIsIf must at least be read-only
    returning true(2)."
    GROUP mplsTunnelOptionalGroup
    DESCRIPTION
    "Objects in this group are optional."
    -- mplsTunnelTable
    OBJECT mplsTunnelName
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelDescr
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelIsIf
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelIfIndex
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelXCPointer
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelSignallingProto
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelSetupPrio
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHoldingPrio
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelSessionAttributes
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelOwner
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelLocalProtectInUse
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelResourcePointer
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelInstancePriority
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPrimaryInstance
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPrimaryTimeUp
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPathChanges
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelLastPathChange
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelCreationTime
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelStateTransitions
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopTableIndex
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelARHopTableIndex
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelCHopTableIndex
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelAdminStatus
    SYNTAX INTEGER { up (1), down (2) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only up and down states must be supported. Write
    access is not required."
    OBJECT mplsTunnelOperStatus
    SYNTAX INTEGER { up (1), down (2) }
    DESCRIPTION
    "Only up and down states must be supported. Write
    access is not required."
    OBJECT mplsTunnelRowStatus
    SYNTAX INTEGER { active(1), notInService(2),
    createAndGo(4), destroy(6) }
    MIN-ACCESS read-only
    DESCRIPTION
    "The notReady(3) and createAndWait(5) states need
    not be supported. Write access is not required."
    OBJECT mplsTunnelStorageType
    SYNTAX INTEGER { other(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only other (1) needs to be supported."
    OBJECT mplsTunnelPathInUse
    MIN-ACCESS read-only
    DESCRIPTION
    "Read-only support is required."
    OBJECT mplsTunnelRole
    SYNTAX INTEGER { head(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only support for head is required."
    OBJECT mplsTunnelTotalUpTime
    MIN-ACCESS read-only
    DESCRIPTION
    "Read-only support is required."
    OBJECT mplsTunnelInstanceUpTime
    MIN-ACCESS read-only
    DESCRIPTION
    "Read-only support is required."
    -- mplsTunnelHopTable
    OBJECT mplsTunnelHopAddrType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopIpv4Addr
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopIpv4PrefixLen
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopIpv6Addr
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopIpv6PrefixLen
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopAsNumber
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopLspId
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelHopType
    MIN-ACCESS read-only
    DESCRIPTION
    "loose(2) need not be supported. Write access is
    not required."
    OBJECT mplsTunnelHopRowStatus
    SYNTAX INTEGER { active(1), notInService(2),
    createAndGo(4), destroy(6) }
    MIN-ACCESS read-only
    DESCRIPTION
    "The notReady(3) and createAndWait(5) states need
    not be supported. Write access is not required."
    OBJECT mplsTunnelHopStorageType
    SYNTAX INTEGER { other(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only other (1) needs to be supported."
    -- mplsTunnelResourceTable
    OBJECT mplsTunnelResourceMaxRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelResourceMeanRate
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelResourceMaxBurstSize
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelResourceRowStatus
    SYNTAX INTEGER { active(1), notInService(2),
    createAndGo(4), destroy(6) }
    MIN-ACCESS read-only
    DESCRIPTION
    "The notReady(3) and createAndWait(5) states need
    not be supported. Write access is not required."
    OBJECT mplsTunnelResourceStorageType
    SYNTAX INTEGER { other(1) }
    MIN-ACCESS read-only
    DESCRIPTION
    "Only other (1) needs to be supported."
    -- mplsTunnelPerftable
    OBJECT mplsTunnelPerfPackets
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPerfHCPackets
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPerfErrors
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPerfBytes
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsTunnelPerfHCBytes
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."

    View at oid-info.com

    Description by mibdepot

    Compliance statement for agents that support the
    MPLS TE MIB.

    Parsed from file mpls-te.mib.txt
    Company: None
    Module: MPLS-TE-MIB

    Information by cisco_v1

    mplsTeModuleCompliance OBJECT IDENTIFIER ::= { mplsTeCompliances 1 }

    Information by oid_info

    Automatically extracted from Cisco "SNMP v2 MIBs".

    Information by mibdepot

    mplsTeModuleCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for agents that support the MPLS TE MIB." MODULE MANDATORY-GROUPS { mplsTunnelGroup, mplsTunnelScalarGroup } GROUP mplsTunnelManualGroup DESCRIPTION "This group is mandatory for devices which support manual configuration of tunnels, in addition to mplsTunnelGroup. The following constraints apply: mplsTunnelSignallingProto should be at least read- only with a value of none(1)." GROUP mplsTunnelSignaledGroup DESCRIPTION "This group is mandatory for devices which support signaled tunnel set up, in addition to mplsTunnelGroup. The following constraints apply: mplsTunnelSignallingProto should be at least read- only returning a value of ldp(2), or rsvp(3)." GROUP mplsTunnelIsNotIntfcGroup DESCRIPTION "This group is mandatory for devices which support tunnels that are not interfaces, in addition to mplsTunnelGroup. The following constraints apply: mplsTunnelIsIf must at least be read-only returning false(1)." GROUP mplsTunnelIsIntfcGroup DESCRIPTION "This group is mandatory for devices which support tunnels that are interfaces, in addition to mplsTunnelGroup. The following constraints apply: mplsTunnelIsIf must at least be read-only returning true(2)." GROUP mplsTunnelOptionalGroup DESCRIPTION "Objects in this group are optional." OBJECT mplsTunnelName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelDescr MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelIsIf MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelIfIndex DESCRIPTION "Write access is not required." OBJECT mplsTunnelXCPointer MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelSignallingProto MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelSetupPrio MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHoldingPrio MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelSessionAttributes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelOwner MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelLocalProtectInUse MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourcePointer MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelInstancePriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopTableIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPrimaryInstance MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPrimaryTimeUp MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPathChanges MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelLastPathChange MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelCreationTime MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelStateTransitions MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelARHopTableIndex DESCRIPTION "Write access is not required." OBJECT mplsTunnelCHopTableIndex DESCRIPTION "Write access is not required." OBJECT mplsTunnelAdminStatus SYNTAX INTEGER { up (1), down (2) } MIN-ACCESS read-only DESCRIPTION "Only up and down states must be supported. Write access is not required." OBJECT mplsTunnelOperStatus SYNTAX INTEGER { up (1), down (2) } DESCRIPTION "Only up and down states must be supported. Write access is not required." OBJECT mplsTunnelRowStatus SYNTAX INTEGER { active(1), notInService(2), createAndGo(4), destroy(6) } MIN-ACCESS read-only DESCRIPTION "The notReady(3) and createAndWait(5) states need not be supported. Write access is not required." OBJECT mplsTunnelStorageType SYNTAX INTEGER { other(1) } MIN-ACCESS read-only DESCRIPTION "Only other (1) needs to be supported." OBJECT mplsTunnelPathInUse MIN-ACCESS read-only DESCRIPTION "Read-only support is required." OBJECT mplsTunnelRole SYNTAX INTEGER { head(1) } MIN-ACCESS read-only DESCRIPTION "Only support for head is required." OBJECT mplsTunnelTotalUpTime MIN-ACCESS read-only DESCRIPTION "Read-only support is required." OBJECT mplsTunnelInstanceUpTime MIN-ACCESS read-only DESCRIPTION "Read-only support is required." OBJECT mplsTunnelHopAddrType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopIpv4Addr MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopIpv4PrefixLen MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopIpv6Addr MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopIpv6PrefixLen MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopAsNumber MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopLspId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopType SYNTAX INTEGER { strict(1) } MIN-ACCESS read-only DESCRIPTION "loose(2) need not be supported. Write access is not required." OBJECT mplsTunnelHopIncludeExclude MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopPathOptionName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopEntryPathComp MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelHopRowStatus SYNTAX INTEGER { active(1), notInService(2), createAndGo(4), destroy(6) } MIN-ACCESS read-only DESCRIPTION "The notReady(3) and createAndWait(5) states need not be supported. Write access is not required." OBJECT mplsTunnelHopStorageType SYNTAX INTEGER { other(1) } MIN-ACCESS read-only DESCRIPTION "Only other (1) needs to be supported." OBJECT mplsTunnelResourceMaxRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceMeanRate MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceMaxBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceMeanBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceExcessBurstSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceFrequency MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceWeight MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelResourceRowStatus SYNTAX INTEGER { active(1), notInService(2), createAndGo(4), destroy(6) } MIN-ACCESS read-only DESCRIPTION "The notReady(3) and createAndWait(5) states need not be supported. Write access is not required." OBJECT mplsTunnelResourceStorageType SYNTAX INTEGER { other(1) } MIN-ACCESS read-only DESCRIPTION "Only other (1) needs to be supported." OBJECT mplsTunnelPerfPackets MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPerfHCPackets MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPerfErrors MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPerfBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsTunnelPerfHCBytes MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { mplsTeCompliances 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.3)

    Internet Assigned Numbers Authority