The error code of for errors from this collector.
Parsed from file vrts.mib.txt
Company: None
Module: VRTS-SNMP-MIBv1
The error code of for errors from this collector.
Parsed from file VRTS-SNMP-MIBv1.mib
Module: VRTS-SNMP-MIBv1
Vendor: Veritas
Module: VRTS-SNMP-MIBv1 (vrts.mib)
Type: TABULAR
Access: read-only
Syntax: Integer32
Automatically extracted from www.mibdepot.com
clErrcode OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The error code of for errors from this collector." ::= { clEntry 100 }
clErrcode OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The error code of for errors from this collector." ::= { clEntry 100 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1035.301.4.1.1.1 | clIndex | 0 | 0 | Reference Index for each the collector. |
1.3.6.1.4.1.1035.301.4.1.1.2 | clName | 0 | 0 | The collector name. |
1.3.6.1.4.1.1035.301.4.1.1.3 | clHost | 0 | 0 | The hostname where collector is running. |
1.3.6.1.4.1.1035.301.4.1.1.4 | clScript | 0 | 0 | The collector script file name, if will be prefixed with $ENEDir\config\Scripts directory |
1.3.6.1.4.1.1035.301.4.1.1.5 | clSampFreq | 0 | 0 | The frequency in seconds that the collector script is executed. |
1.3.6.1.4.1.1035.301.4.1.1.6 | clFreq | 0 | 0 | The frequency in seconds which specifies how frequent should ENE agent check whether the collected data is ready. The optimal v… |
1.3.6.1.4.1.1035.301.4.1.1.7 | clTimeout | 0 | 0 | If no data after clTimeout seconds, then the collecting session is aborted. |
1.3.6.1.4.1.1035.301.4.1.1.8 | clPrdCode | 0 | 0 | The VERITAS product code of which the collector is associated, it can be 0: NetBackup, 1: VxVM, 2: VxFS, 7: VCS etc. |
1.3.6.1.4.1.1035.301.4.1.1.9 | clPrdName | 0 | 0 | The VERITAS product name of which the collector is associated, it can be NetBackup, VxVM, VxFS, VCS etc. |
1.3.6.1.4.1.1035.301.4.1.1.10 | clObjName | 0 | 0 | The object name of the collection. For example, it can be NetBackup job, tape drive, or VxVM's subdisk, or VCS's service etc. |
1.3.6.1.4.1.1035.301.4.1.1.11 | clAttrName | 0 | 0 | The attribute name of which the collection is associated. For example, it can be NetBackup job's Kbytes attribute, tape drive's… |
1.3.6.1.4.1.1035.301.4.1.1.12 | clLow | 0 | 0 | Indicate low threshold for the collected attribute value. If violated, event will be sent. |
1.3.6.1.4.1.1035.301.4.1.1.13 | clHigh | 0 | 0 | Indicate high threshold for the collected attribute value. If violated, event will be sent. |
1.3.6.1.4.1.1035.301.4.1.1.14 | clCount | 0 | 0 | The number of objects which we care about whether its attribute value is within low and high threshold. 0 means we are all obje… |
1.3.6.1.4.1.1035.301.4.1.1.15 | clObjNames | 0 | 0 | List of object names, seperated by ';', which we care when threshold is violated. Leave name empty make it a wild card, means w… |
1.3.6.1.4.1.1035.301.4.1.1.16 | clResolution | 0 | 0 | Text resulotion when threshold value is violated. |
1.3.6.1.4.1.1035.301.4.1.1.99 | clErrFlag | 0 | 0 | Set the flag to 1 to indicate the threshold is violated. 0 means no error. |
1.3.6.1.4.1.1035.301.4.1.1.101 | clErrmsg | 0 | 0 | The error message of the threshold violation. |
1.3.6.1.4.1.1035.301.4.1.1.102 | clErrFix | 0 | 0 | Setting this error fix flag to 1 to kick off the clErrFixCmd. |
1.3.6.1.4.1.1035.301.4.1.1.103 | clErrFixCmd | 0 | 0 | The command that will be executed when the clErrFix column is set to 1. |