Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlPhdModuleHotSwapOperStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"on",
"(",
"1",
")",
",",
"off",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The current Hot Swap state of the module. If rlPhdModuleHotSwapAdminStatus is down(2) then rlPhdModuleHotSwapOperStatus should be down(2). If rlPhdModuleHotSwapAdminStatus is changed to up(1) then rlPhdModuleHotSwapOperStatus should change to up(1) if the module presents; it should remain in the down(2) state if and only if the module does not present.\"",
"::=",
"{",
"rlPhdModuleHotSwapEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"on",
1
],
[
"off",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The current Hot Swap state of the module. If rlPhdModuleHotSwapAdminStatus is down(2) then rlPhdModuleHotSwapOperStatus should be down(2). If rlPhdModuleHotSwapAdminStatus is changed to up(1) then rlPhdModuleHotSwapOperStatus should change to up(1) if the module presents; it should remain in the down(2) state if and only if the module does not present."
],
null,
null,
null,
null
]
}
- HPE Instant On official MIBs
· Publisher's source file: hpe-physdescription.mib
Module: HPE-Physicaldescription-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'HPE-MIB': ['nm', 'rndNotifications'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE', 'Unsigned32'], 'HPE-HWENVIROMENT': ['RlEnvMonState'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'HPE-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download hpe-physdescription.mib
Same file in HPE Instant On 1960 2.6.0.73.
Same file in HPE Instant On 1830 2.5.0.48.
Same file in HPE Instant On 1960 2.7.0.103.
Same file in HPE Instant On 1960 2.8.1.35.
- HPE Instant On official MIBs
· Publisher's source file: hpe-physdescription.mib
Module: HPE-Physicaldescription-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'HPE-MIB': ['nm', 'rndNotifications'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE', 'Unsigned32'], 'Q-BRIDGE-MIB': ['PortList'], 'HPE-HWENVIROMENT': ['RlEnvMonState'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'HPE-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download hpe-physdescription.mib
Same file in HPE Instant On 1930 2.6.0.73.
Same file in HPE Instant On 1930 2.5.0.42.
Same file in HPE Instant On 1930 2.8.1.35.
Same file in HPE Instant On 1930 3.2.0.8.
- HPE Instant On official MIBs
· Publisher's source file: hpe-physdescription.mib
Module: HPE-Physicaldescription-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'HPE-MIB': ['nm', 'rndNotifications'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE', 'Unsigned32'], 'HPE-HWENVIROMENT': ['RlEnvMonState'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'HPE-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download hpe-physdescription.mib
- HPE networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
HPE networking support.
Module: HPE-Physicaldescription-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'HPE-MIB': ['nm', 'rndNotifications'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE', 'Unsigned32'], 'Q-BRIDGE-MIB': ['PortList'], 'HPE-HWENVIROMENT': ['RlEnvMonState'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'HPE-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}
· Download HPE-Physicaldescription-MIB
Related source files and packages: