OID reference

rlPhyTestGetUnits

1.3.6.1.4.1.11.2.90.1.2.1.4

Description

The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diag…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.11.2.90.1.2.1 (rlPhyTestGetEntry)
Node code
4
Node name
rlPhyTestGetUnits
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.11.2.90.1.2.1.4
URN notation
urn:oid:1.3.6.1.4.1.11.2.90.1.2.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 11 2 90 1 2 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hP(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hP(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hpPrintServer(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hpPrintServer(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hP(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hP(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hpPrintServer(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hpPrintServer(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hP(11) nm(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hP(11) wireless(2) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/11/2/90/1/2/1/4
  • /ISO/Identified-Organization/6/1/4/1/11/2/90/1/2/1/4
  • /ISO/3/6/1/4/1/11/2/90/1/2/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/hp/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/hp/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/IMPORTS/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/IMPORTS/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/hP/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/hP/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/hpPrintServer/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/hpPrintServer/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/HP/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprise/HP/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/hp/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/hp/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/IMPORTS/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/IMPORTS/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/hP/nm/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/hP/wireless/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

Notes below names come from selected MIB definitions.

ValueName and source notes
1integer
2boolean
3downUP
4reverseNormal
5mdiMdix
6meter
7degree
Celsius
8microVolt
9microOham
10microAmper
11microWatt
12millisecond
13alaskaPhyLength
14alaskaPhyStatus
15dbm
16decidbm
17milidbm
18abcd
19nanosecond

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: ifIndex, rlPhyTestGetType.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.11.2.90.1.2.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

rlPhyTestGetUnits   OBJECT-TYPE
   SYNTAX  INTEGER {
        integer(1),
        boolean(2),
        downUP(3),
        reverseNormal(4),
        mdiMdix(5),
        meter(6),
        degree(7),  -- Celsius
        microVolt(8),
        microOham(9),
        microAmper(10),
        microWatt(11),
        millisecond(12),
        alaskaPhyLength(13),
        alaskaPhyStatus(14),
        dbm(15),
        decidbm(16),
        milidbm(17),
        abcd(18),
        nanosecond(19)
            }
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The test result unit of measure. The units can be standard unit or special units
         that are designed for special test.

         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
         less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).

         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
         4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
   ::= { rlPhyTestGetEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)HPE Instant On official MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1HPE networking MIB copies (LibreNMS/Observium Community), HPE Instant On official MIBs1 record · 2 sources

Description 1

rlPhyTestGetUnits · currentHPE networking MIB copies (LibreNMS/Observium Community), HPE Instant On official MIBs2 sources

Status in source: current.

Names: rlPhyTestGetUnits

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rlPhyTestGetUnits",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "integer",
    "(",
    "1",
    ")",
    ",",
    "boolean",
    "(",
    "2",
    ")",
    ",",
    "downUP",
    "(",
    "3",
    ")",
    ",",
    "reverseNormal",
    "(",
    "4",
    ")",
    ",",
    "mdiMdix",
    "(",
    "5",
    ")",
    ",",
    "meter",
    "(",
    "6",
    ")",
    ",",
    "degree",
    "(",
    "7",
    ")",
    ",",
    "microVolt",
    "(",
    "8",
    ")",
    ",",
    "microOham",
    "(",
    "9",
    ")",
    ",",
    "microAmper",
    "(",
    "10",
    ")",
    ",",
    "microWatt",
    "(",
    "11",
    ")",
    ",",
    "millisecond",
    "(",
    "12",
    ")",
    ",",
    "alaskaPhyLength",
    "(",
    "13",
    ")",
    ",",
    "alaskaPhyStatus",
    "(",
    "14",
    ")",
    ",",
    "dbm",
    "(",
    "15",
    ")",
    ",",
    "decidbm",
    "(",
    "16",
    ")",
    ",",
    "milidbm",
    "(",
    "17",
    ")",
    ",",
    "abcd",
    "(",
    "18",
    ")",
    ",",
    "nanosecond",
    "(",
    "19",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).\"",
    "::=",
    "{",
    "rlPhyTestGetEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "integer",
            1
          ],
          [
            "boolean",
            2
          ],
          [
            "downUP",
            3
          ],
          [
            "reverseNormal",
            4
          ],
          [
            "mdiMdix",
            5
          ],
          [
            "meter",
            6
          ],
          [
            "degree",
            7
          ],
          [
            "microVolt",
            8
          ],
          [
            "microOham",
            9
          ],
          [
            "microAmper",
            10
          ],
          [
            "microWatt",
            11
          ],
          [
            "millisecond",
            12
          ],
          [
            "alaskaPhyLength",
            13
          ],
          [
            "alaskaPhyStatus",
            14
          ],
          [
            "dbm",
            15
          ],
          [
            "decidbm",
            16
          ],
          [
            "milidbm",
            17
          ],
          [
            "abcd",
            18
          ],
          [
            "nanosecond",
            19
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.11)

Peterson Tyler

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.11.2.90.1.2.1.1 rlPhyTestGetType00
1.3.6.1.4.1.11.2.90.1.2.1.2 rlPhyTestGetStatus00
1.3.6.1.4.1.11.2.90.1.2.1.3 rlPhyTestGetResult00
1.3.6.1.4.1.11.2.90.1.2.1.5 rlPhyTestGetAlarm00
1.3.6.1.4.1.11.2.90.1.2.1.6 rlPhyTestGetTimeStamp00