Reference record for OID 1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3



parent
1.3.6.1.4.1.11096.6.1.1.1.1.2.1 (puConfigEntry)
node code
3
node name
puConfigShutdownInterval
dot oid
1.3.6.1.4.1.11096.6.1.1.1.1.2.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) blueArc(11096) blueArcPrivate(6) blueArcServer(1) blueArcServerObjs(1) sys(1) powerUnits(1) puConfigTable(2) puConfigEntry(1) puConfigShutdownInterval(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • /iso/identified-organization/dod/internet/private/enterprises/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • /iso/org/dod/internet/private/enterprise/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • /iso/org/dod/internet/private/enterprises/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • /iso/iso-identified-organization/dod/internet/private/enterprise/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • /iso/iso-identified-organization/dod/internet/private/enterprises/blueArc/blueArcPrivate/blueArcServer/blueArcServerObjs/sys/powerUnits/puConfigTable/puConfigEntry/puConfigShutdownInterval
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/11096/6/1/1/1/1/2/1/3

    Description by mibdepot

    This variable is used in conjunction with
    puConfigShutdownRemainingLife such that when either
    condition is met a controlled shutdown will take place.

    puConfigShutdownInterval specifies the interval after
    which a controlled shutdown should take place in the event
    of a power outage.

    remainingLife(1) - indicates that the shutdown is based
    on the remaining battery life only and NOT
    the duration of the power outage.
    The variable puConfigShutdownRemainingLife
    determines how the shutdown is controlled.
    immediately(2) - the shutdown should take place as soon as
    the power outage is detected. The variable
    puConfigRemainingLife is irrelevant in this
    case.
    oneMinute(3),
    twoMinutes(4),
    threeMinutes(5), - the interval after which a controlled
    fiveMinutes(6), shutdown should take place in the event of
    tenMinutes(7) a power outage.

    NOTE: the variable puConfigShutdownEnabled must be enabled(1),
    for this variable to have any effect in determining
    when the controlled shutdown is performed.

    This object is obsolete. Power units must be indexed by
    ip address.

    Parsed from file BLUEARC-SERVER-MIB.my.txt
    Company: None
    Module: BLUEARC-SERVER-MIB

    Description by circitor

    This variable is used in conjunction with
    puConfigShutdownRemainingLife such that when either
    condition is met a controlled shutdown will take place.

    puConfigShutdownInterval specifies the interval after
    which a controlled shutdown should take place in the event
    of a power outage.

    remainingLife(1) - indicates that the shutdown is based
    on the remaining battery life only and NOT
    the duration of the power outage.
    The variable puConfigShutdownRemainingLife
    determines how the shutdown is controlled.
    immediately(2) - the shutdown should take place as soon as
    the power outage is detected. The variable
    puConfigRemainingLife is irrelevant in this
    case.
    oneMinute(3),
    twoMinutes(4),
    threeMinutes(5), - the interval after which a controlled
    fiveMinutes(6), shutdown should take place in the event of
    tenMinutes(7) a power outage.

    NOTE: the variable puConfigShutdownEnabled must be enabled(1),
    for this variable to have any effect in determining
    when the controlled shutdown is performed.

    This object is obsolete. Power units must be indexed by
    IP address.

    Parsed from file BLUEARC-SERVER-MIB.mib
    Module: BLUEARC-SERVER-MIB

    Information by oid_info

    Vendor: BlueArc Corporation
    Module: BLUEARC-SERVER-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    puConfigShutdownInterval OBJECT-TYPE SYNTAX INTEGER { remainingLife(1), immediately(2), oneMinute(3), twoMinutes(4), threeMinutes(5), fiveMinutes(6), tenMinutes(7) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This variable is used in conjunction with puConfigShutdownRemainingLife such that when either condition is met a controlled shutdown will take place. puConfigShutdownInterval specifies the interval after which a controlled shutdown should take place in the event of a power outage. remainingLife(1) - indicates that the shutdown is based on the remaining battery life only and NOT the duration of the power outage. The variable puConfigShutdownRemainingLife determines how the shutdown is controlled. immediately(2) - the shutdown should take place as soon as the power outage is detected. The variable puConfigRemainingLife is irrelevant in this case. oneMinute(3), twoMinutes(4), threeMinutes(5), - the interval after which a controlled fiveMinutes(6), shutdown should take place in the event of tenMinutes(7) a power outage. NOTE: the variable puConfigShutdownEnabled must be enabled(1), for this variable to have any effect in determining when the controlled shutdown is performed. This object is obsolete. Power units must be indexed by ip address." ::= { puConfigEntry 3 }

    Information by circitor

    puConfigShutdownInterval OBJECT-TYPE SYNTAX INTEGER { remainingLife(1), immediately(2), oneMinute(3), twoMinutes(4), threeMinutes(5), fiveMinutes(6), tenMinutes(7) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This variable is used in conjunction with puConfigShutdownRemainingLife such that when either condition is met a controlled shutdown will take place. puConfigShutdownInterval specifies the interval after which a controlled shutdown should take place in the event of a power outage. remainingLife(1) - indicates that the shutdown is based on the remaining battery life only and NOT the duration of the power outage. The variable puConfigShutdownRemainingLife determines how the shutdown is controlled. immediately(2) - the shutdown should take place as soon as the power outage is detected. The variable puConfigRemainingLife is irrelevant in this case. oneMinute(3), twoMinutes(4), threeMinutes(5), - the interval after which a controlled fiveMinutes(6), shutdown should take place in the event of tenMinutes(7) a power outage. NOTE: the variable puConfigShutdownEnabled must be enabled(1), for this variable to have any effect in determining when the controlled shutdown is performed. This object is obsolete. Power units must be indexed by IP address." ::= { puConfigEntry 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.11096)

    Cooper Michael

    Brothers (5)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.11096.6.1.1.1.1.2.1.1 puConfigIndex 0 0 A unique value for each power unit which may be present on
    this system.

    Its value ranges between 1 and the value of puConfigNumbe…
    1.3.6.1.4.1.11096.6.1.1.1.1.2.1.2 puConfigShutdownEnabled 0 0 Indicates whether the power unit is to control the shutdown
    of the system when a power outage is detected.

    enabled(1) - the powe…
    1.3.6.1.4.1.11096.6.1.1.1.1.2.1.4 puConfigShutdownRemainingLife 0 0 Specifies the number of minutes of battery life which when
    depleted will cause a controlled shutdown of the system.

    NOTE: the var…
    1.3.6.1.4.1.11096.6.1.1.1.1.2.1.5 puConfigCommsOK 0 0 Indicates whether the system is currently communicating with
    the power unit.

    This object is obsolete. Power units must be indexed…
    1.3.6.1.4.1.11096.6.1.1.1.1.2.1.6 puConfigCommsEverOK 0 0 Indicates whether the system has ever communicated
    with the power unit.

    This object is obsolete. Power units must be indexed by
    ip…