Indicates whether the system has ever communicated
with the power unit.
Parsed from file BLUEARC-SERVER-MIB.my.txt
Company: None
Module: BLUEARC-SERVER-MIB
Indicates whether the system has ever communicated
with the power unit.
Parsed from file BLUEARC-SERVER-MIB.mib
Module: BLUEARC-SERVER-MIB
Vendor: BlueArc Corporation
Module: BLUEARC-SERVER-MIB
[Automatically extracted from oidview.com]
puConfigurationCommsEverOK OBJECT-TYPE SYNTAX INTEGER { communicated(1), neverCommunicated(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the system has ever communicated with the power unit." ::= { puConfigurationEntry 9 }
puConfigurationCommsEverOK OBJECT-TYPE SYNTAX INTEGER { communicated(1), neverCommunicated(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the system has ever communicated with the power unit." ::= { puConfigurationEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.1 | puConfigurationIndex | 0 | 0 | An IP address for each power unit which may be present on this system. 0.0.0.0 is given for a serial-attached UPS. |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.2 | puConfigurationUserName | 0 | 0 | The UPS management card's admin user name, used with the authentication phrase for authenticating status updates from the UPS. Em… |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.3 | puConfigurationMonitoringEnabled | 0 | 0 | Indicates whether monitoring is enabled on the UPS. If monitoring is enabled, then the power unit is to control the shutdown of t… |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.4 | puConfigurationShutdownOnBattery | 0 | 0 | If the value is not -1, then the system will be shut down after running on battery for the specified time in minutes. |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.5 | puConfigurationShutdownOnRuntime | 0 | 0 | If the value is not -1, then shutdown will occur when the estimated remaining runtime falls below the specified value in minutes. |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.6 | puConfigurationShutdownOnLowBattery | 0 | 0 | If the value is not -1, then the system will shut down when UPS reports a low battery, with a delay of the specified number of mi… |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.7 | puConfigurationOnBatteryTolerance | 0 | 0 | The length of time, in seconds, for which the UPS must be on battery before the system will act on it, no matter what the shutdow… |
1.3.6.1.4.1.11096.6.1.1.1.1.8.1.8 | puConfigurationCommsOK | 0 | 0 | Indicates whether the system is currently communicating with the power unit. |