Indicates whether the temperature measurement is within the
expected range.
ok(1) - the reading is within the expected range.
tempWarning(2) - the reading is outside of the expected
range, but not severe.
tempSevere(3) - The reading is severely outside the
expected range.
tempSensoreFailed(4) - the sensor unit has failed. The measured
temperature is invalid
tempSensorWarning(5) - the sensor unit is in a warning condition.
unknown(6) - the status of the sensor could not be
determined.
Parsed from file BLUEARC-SERVER-MIB.my.txt
Company: None
Module: BLUEARC-SERVER-MIB
Indicates whether the temperature measurement is within the
expected range.
ok(1) - the reading is within the expected range.
tempWarning(2) - the reading is outside of the expected
range, but not severe.
tempSevere(3) - The reading is severely outside the
expected range.
tempSensoreFailed(4) - the sensor unit has failed. The measured
temperature is invalid
tempSensorWarning(5) - the sensor unit is in a warning condition.
unknown(6) - the status of the sensor could not be
determined.
Parsed from file BLUEARC-SERVER-MIB.mib
Module: BLUEARC-SERVER-MIB
Vendor: BlueArc Corporation
Module: BLUEARC-SERVER-MIB
[Automatically extracted from oidview.com]
temperatureSensorStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), tempWarning(2), tempSevere(3), tempSensorFailed(4), tempSensorWarning(5), unknown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the temperature measurement is within the expected range. ok(1) - the reading is within the expected range. tempWarning(2) - the reading is outside of the expected range, but not severe. tempSevere(3) - The reading is severely outside the expected range. tempSensoreFailed(4) - the sensor unit has failed. The measured temperature is invalid tempSensorWarning(5) - the sensor unit is in a warning condition. unknown(6) - the status of the sensor could not be determined." ::= { temperatureSensorEntry 3 }
temperatureSensorStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), tempWarning(2), tempSevere(3), tempSensorFailed(4), tempSensorWarning(5), unknown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the temperature measurement is within the expected range. ok(1) - the reading is within the expected range. tempWarning(2) - the reading is outside of the expected range, but not severe. tempSevere(3) - The reading is severely outside the expected range. tempSensoreFailed(4) - the sensor unit has failed. The measured temperature is invalid tempSensorWarning(5) - the sensor unit is in a warning condition. unknown(6) - the status of the sensor could not be determined." ::= { temperatureSensorEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11096.6.1.1.1.2.1.9.1.1 | temperatureSensorClusterNode | 0 | 0 | The ID of the Cluster Node in which the fan is located. |
1.3.6.1.4.1.11096.6.1.1.1.2.1.9.1.2 | temperatureSensorIndex | 0 | 0 | A unique value for each temperature sensor on a cluster node. |
1.3.6.1.4.1.11096.6.1.1.1.2.1.9.1.4 | temperatureSensorCReading | 0 | 0 | A measurement of the temperature taken by the sensor in degrees Celsius. |
1.3.6.1.4.1.11096.6.1.1.1.2.1.9.1.5 | temperatureSensorFReading | 0 | 0 | A measurement of the temperature taken by the sensor in degrees Fahrenheit. |