Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"apexPsiRangeStop",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"31",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Maximum PSI version number. Used to limit the APEX to use a specific range of PSI numbers. Set this to 31 to allow the APEX to use the full range of PSI version numbers (requires apexPsiRangeStart to be set to 0). Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter. @Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(config.ini, type='ini') \"",
"::=",
"{",
"apexPsiConfigGeneral",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
31
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Maximum PSI version number. Used to limit the APEX to use a specific range of PSI numbers. Set this to 31 to allow the APEX to use the full range of PSI version numbers (requires apexPsiRangeStart to be set to 0). Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter. @Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(config.ini, type='ini')"
],
null,
null,
null,
null
]
}