The value of this object identifies the index of the alarm object to be modified.
Sources for this description
General Instrument GX2 MIB copies with Oracle inventory
OID reference
1.3.6.1.4.1.1166.6.1.2.7.5.4.2
The value of this object identifies the index of the alarm object to be modified.
Identification
{1 3 6 1 4 1 1166 6 1 2 7 5 4 2}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In OMNI-gx2PSDC-MIB, the row index consists of these components in order:
rxgx2PsdcHoldTimeTableIndex (INTEGER): one numeric subidentifier for the non-negative value.rxgx2PsdcHoldTimeSpecIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.1166.6.1.2.7.5.4.2.<rxgx2PsdcHoldTimeTableIndex>.<rxgx2PsdcHoldTimeSpecIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1166.6.1.2.7.5.4.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rxgx2PsdcHoldTimeSpecIndex OBJECT-TYPE
SYNTAX INTEGER (1..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the index of the alarm object to be modified."
::= { gx2PsdcHoldTimeEntry 2}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of this object identifies the index of the alarm object to be modified.
General Instrument GX2 MIB copies with Oracle inventory
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rxgx2PsdcHoldTimeSpecIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rxgx2PsdcHoldTimeSpecIndex",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"1",
".",
".",
"4294967295",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The value of this object identifies the index of the alarm object to be modified.\"",
"::=",
"{",
"gx2PsdcHoldTimeEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
1,
4294967295
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The value of this object identifies the index of the alarm object to be modified."
],
null,
null,
null,
null
]
}Module: OMNI-gx2PSDC-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'GX2HFC-MIB': ['gx2Psdc'], 'RFC1155-SMI': ['Counter', 'IpAddress', 'TimeTicks'], 'RFC1213-MIB': ['sysUpTime', 'DisplayString'], 'NLS-BBNIDENT-MIB': ['gi', 'motproxies'], 'NLSBBN-TRAPS-MIB': ['trapIdentifier', 'trapNetworkElemModelNumber', 'trapNetworkElemSerialNum', 'trapPerceivedSeverity', 'trapNetworkElemOperState', 'trapNetworkElemAlarmStatus', 'trapNetworkElemAdminState', 'trapNetworkElemAvailStatus', 'trapText', 'trapNETrapLastTrapTimeStamp', 'trapChangedObjectId', 'trapChangedValueInteger', 'trapChangedValueDisplayString']}Source data warning: This is a third-party IPNetwork Monitor archive copy attributed to General Instrument, Motorola or ARRIS. Oracle lists the corresponding module family as supported; the manufacturer distribution and applicability to particular devices or firmware have not been independently confirmed.
· Download General Instrument OMNI-gx2PSDC-MIB — IPNetwork Monitor archive copyRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.7.5.4.1 | rxgx2PsdcHoldTimeTableIndex | 0 | 0 | |
| 1.3.6.1.4.1.1166.6.1.2.7.5.4.3 | rxgx2PsdcHoldTimeData | 0 | 0 |