Vendor: Transmode Systems AB
Module: TRANSMODE1100
[Automatically extracted from oidview.com]
trmAlarmGeneral OBJECT IDENTIFIER ::= {trmAlarmConfig 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.1.1.1.1 | trmAutoAcknowledge | 0 | 0 | Indicates if alarms should be automatically acknowledged or not. Can be on(1) or off(2). |
1.3.6.1.4.1.11857.1.1.1.1.2 | trmClearAlarmLog | 0 | 0 | Used to delete all history alarms. To delete all history alarms, a SetRequest-PDU with a clear(1) value encoding is used. |
1.3.6.1.4.1.11857.1.1.1.1.3 | trmTemperature | 0 | 0 | Indicates the temperature unit used in the system. Can be celsius(1) or farenheit(2). |
1.3.6.1.4.1.11857.1.1.1.1.4 | trmAlarmTemperatureHigh | 0 | 0 | High temperature level. This parameter indicates at what level a High temperature alarm will occur in the system. See trmTemperatu… |
1.3.6.1.4.1.11857.1.1.1.1.5 | trmAlarmTemperatureHighHyst | 0 | 0 | High termperature hysteresis. This parameter is used together with trmAlarmTempemperatureHigh to decide when a High temperature a… |
1.3.6.1.4.1.11857.1.1.1.1.6 | trmAlarmTemperatureLow | 0 | 0 | Low temperature level. This parameter indicates at what level a Low temperature alarm will occur in the system. See trmTemperature… |
1.3.6.1.4.1.11857.1.1.1.1.7 | trmAlarmTemperatureLowHyst | 0 | 0 | Low termperature hysteresis. This parameter is used together with trmAlarmTemperatureLow to decide when a Low temperature alarm w… |
1.3.6.1.4.1.11857.1.1.1.1.8 | trmPluginReset | 0 | 0 | Used to reset all the plug in units. To reset all units, a SetRequest-PDU with a reset(1) value encoding is used. |
1.3.6.1.4.1.11857.1.1.1.1.9 | trmOpticalInputPowerHighPINLine | 0 | 0 | Optical input power high alarm level for line interface PINs. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.10 | trmOpticalInputPowerHighAPDLine | 0 | 0 | Optical input power high alarm level for client interface APDs. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.11 | trmOpticalInputPowerLowPINLine | 0 | 0 | Optical input power low alarm level for client interface PINs. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.12 | trmOpticalInputPowerLowAPDLine | 0 | 0 | Optical input power low alarm level for client interface APDs. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.13 | trmCascade | 0 | 0 | Shows if Cascading is activated or not and is also used to enable/diasable Cascading. activate(1) means activated and deactivate(… |
1.3.6.1.4.1.11857.1.1.1.1.14 | trmCascadeStatus | 0 | 0 | Displays the current operating mode of the Cascading. Can be deactivated[1], initializing(2), ok(3) or failure(4). |
1.3.6.1.4.1.11857.1.1.1.1.15 | trmOpticalInputPowerHighAPDLine2 | 0 | 0 | Optical input power high alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set … |
1.3.6.1.4.1.11857.1.1.1.1.16 | trmOpticalInputPowerLowAPDLine2 | 0 | 0 | Optical input power low alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set i… |
1.3.6.1.4.1.11857.1.1.1.1.17 | trmOpticalInputPowerHigh850Client | 0 | 0 | Optical input power high alarm level for 850 nm client interface. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.18 | trmOpticalInputPowerHigh1310Client | 0 | 0 | Optical input power high alarm level for 1310 nm client interface. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.19 | trmOpticalInputPowerLow850Client | 0 | 0 | Optical input power low alarm level for 850 nm client interface. Value displayed and set is dBm/10. |
1.3.6.1.4.1.11857.1.1.1.1.20 | trmOpticalInputPowerLow1310Client | 0 | 0 | Optical input power low alarm level for 1310 nm client interface. Value displayed and set is dBm/10. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11857.1.1.1.2 | trmAlarmSeverity | 1 | 5 | None |
1.3.6.1.4.1.11857.1.1.1.3 | trmAlarmExternal | 1 | 5 | None |