Reference record for OID 1.3.6.1.4.1.11857.1.2.2.4.2.0.19



parent
1.3.6.1.4.1.11857.1.2.2.4.2.0 (trm76xxTraps)
node code
19
node name
trm76xxTrapTxDisable
dot oid
1.3.6.1.4.1.11857.1.2.2.4.2.0.19
type
NOTIFICATION-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transmode(11857) system1100(1) trmSubrack(2) trmSubrackUnits(2) trm76xx(4) trm76xxFM(2) trm76xxTraps(0) trm76xxTrapTxDisable(19)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • /iso/identified-organization/dod/internet/private/enterprises/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • /iso/org/dod/internet/private/enterprise/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • /iso/org/dod/internet/private/enterprises/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transmode/system1100/trmSubrack/trmSubrackUnits/trm76xx/trm76xxFM/trm76xxTraps/trm76xxTrapTxDisable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/11857/1/2/2/4/2/0/19

    Description by circitor

    This trap is sent when the optical output power for
    both the line and client interface have been
    disabled.

    Parsed from file TRANSMODE1100.mib
    Module: TRANSMODE1100

    Information by oid_info

    Vendor: Transmode Systems AB
    Module: TRANSMODE1100

    [Automatically extracted from oidview.com]

    Information by circitor

    trm76xxTrapTxDisable NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for both the line and client interface have been disabled." ::= { trm76xxTraps 19 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.11857)

    Henrik Löfgren

    Brothers (21)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.11857.1.2.2.4.2.0.1 trm76xxTrapCDRAutoModeRangeChangeLine 0 0 This trap is sent when a client equipment might be
    using a protocol not specified for auto mode or it
    might have changed the prot…
    1.3.6.1.4.1.11857.1.2.2.4.2.0.2 trm76xxTrapRxGlitchLine 0 0 This trap is sent when a unit experiences a split second
    optical input power glitch at the line interface.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.3 trm76xxTrapLopLine 0 0 This trap is sent when the optical input power is
    lost at the line interface.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.4 trm76xxTrapRxHighPowerLine 0 0 This trap is sent when the optical input power for
    line is higher than trmOpticalInputPowerHighPINLine
    or trmOpticalInputPowerHig…
    1.3.6.1.4.1.11857.1.2.2.4.2.0.5 trm76xxTrapRxLowPowerLine 0 0 This trap is sent when the optical input power for
    line is lower than trmOpticalInputPowerLowPINLine or
    trmOpticalInputPowerLowAP…
    1.3.6.1.4.1.11857.1.2.2.4.2.0.6 trm76xxTrapLoLLine 0 0 This trap is sent when the line Tx indicates loss
    of 3R synchronization.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.7 trm76xxTrapTxLine 0 0 This trap is sent when a unit fails to generate
    optical output power at Tx line.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.8 trm76xxTrapSFPFailureLine 0 0 This trap/alarm is not used in the system and is obsolete.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.9 trm76xxTrapSFPMissingLine 0 0 This trap/alarm is not used in the system and is obsolete.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.10 trm76xxTrapCDRAutoModeRangeChangeClient 0 0 This trap is sent when a client equipment might be
    using a protocol not specified for auto mode or it
    might have changed the prot…
    1.3.6.1.4.1.11857.1.2.2.4.2.0.11 trm76xxTrapRxGlitchClient 0 0 This trap is sent when a unit experiences a split second
    optical input power glitch at the client interface.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.12 trm76xxTrapLopClient 0 0 This trap is sent when the optical input power is
    lost at the client interface.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.13 trm76xxTrapRxHighPowerClient 0 0 This trap/alarm is not used in the system and the object is obsolete.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.14 trm76xxTrapRxLowPowerClient 0 0 This trap/alarm is not used in the system and the object is obsolete.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.15 trm76xxTrapLoLClient 0 0 This trap is sent when the client Tx indicates loss
    of 3R synchronization.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.16 trm76xxTrapTxClient 0 0 This trap is sent when a unit fails to generate
    optical output power at Tx client.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.17 trm76xxTrapSFPFailureClient 0 0 This trap is sent when a unit have a client SFP transiever
    got a failure or a Bias temperature alarm.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.18 trm76xxTrapSFPMissingClient 0 0 This trap is sent when a unit doesn't have a client
    SFP transiever.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.20 trm76xxTrapLaserDegradationLine 0 0 This trap is sent when there is a laser degradation on the line
    laser. This means that the laser bias current is raised to be
    abl…
    1.3.6.1.4.1.11857.1.2.2.4.2.0.21 trm76xxTrapEyeQualityLine 0 0 For future use.
    1.3.6.1.4.1.11857.1.2.2.4.2.0.22 trm76xxTrapEyeQualityClient 0 0 For future use.