Description 1
the lag the port belong to
OID reference
1.3.6.1.4.1.11863.6.31.1.2.1.1.7
the lag the port belong to
Identification
{1 3 6 1 4 1 11863 6 31 1 2 1 1 7}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | macBased | 2 |
| 1 | portBased | 2 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ifIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.11863.6.31.1.2.1.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
tp8021xPortConfigPortLag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the lag the port belong to"
::= { tp8021xPortConfigEntry 7 }tp8021xPortConfigControlType OBJECT-TYPE
SYNTAX INTEGER{
macBased(0),
portBased(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the Control Type for the port.
0. base of mac: Any client connected to the port should pass the 802.1X Authentication for access.
1. base of port: All the clients connected to the port can access the network on the condition
that any one of the clients has passed the 802.1X Authentication. "
::= { tp8021xPortConfigEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
the lag the port belong to
Description 2
Specify the Control Type for the port. 0. base of mac: Any client connected to the port should pass the 802.1X Authentication for access. 1. base of port: All the clients connected to the port can access the network on the condition that any one of the clients has passed the 802.1X Authentication.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tp8021xPortConfigPortLag
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tp8021xPortConfigPortLag",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"255",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"the lag the port belong to\"",
"::=",
"{",
"tp8021xPortConfigEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"the lag the port belong to"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Netdisco archive.
Module: TPLINK-8021X-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress'], 'TPLINK-MIB': ['tplinkMgmt'], 'RFC1213-MIB': ['ifIndex']}Related source files and packages:
Status in source: current.
Names: tp8021xPortConfigControlType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tp8021xPortConfigControlType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"macBased",
"(",
"0",
")",
",",
"portBased",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Specify the Control Type for the port. 0. base of mac: Any client connected to the port should pass the 802.1X Authentication for access. 1. base of port: All the clients connected to the port can access the network on the condition that any one of the clients has passed the 802.1X Authentication. \"",
"::=",
"{",
"tp8021xPortConfigEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"macBased",
0
],
[
"portBased",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Specify the Control Type for the port. 0. base of mac: Any client connected to the port should pass the 802.1X Authentication for access. 1. base of port: All the clients connected to the port can access the network on the condition that any one of the clients has passed the 802.1X Authentication."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: TPLINK-8021X-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'IpAddress'], 'TPLINK-MIB': ['tplinkMgmt'], 'RFC1213-MIB': ['ifIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.1 | tp8021xPortConfigPortIndex | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.2 | tp8021xPortConfigEnable | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.3 | tp8021xPortConfigGuestVlanEnable, tp8021xPortConfigMABEnable | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.4 | tp8021xPortConfigControlMode | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.5 | tp8021xPortConfigControlType | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.6 | tp8021xPortConfigAuthState, tp8021xPortConfigControlMode | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.8 | tp8021xPortConfigGuestVlanID | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.9 | tp8021xPortConfigMaxRequest | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.10 | tp8021xPortConfigQuietPeriod | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.11 | tp8021xPortConfigSuppTimeout | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.12 | tp8021xPortConfigAuthState | 0 | 0 | |
| 1.3.6.1.4.1.11863.6.31.1.2.1.1.13 | tp8021xPortConfigPortLag | 0 | 0 |