Status in source: unconfirmed.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"recConfigMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"other",
"(",
"1",
")",
",",
"onChange",
"(",
"2",
")",
",",
"greaterThanValue",
"(",
"3",
")",
",",
"smallerThanValue",
"(",
"4",
")",
",",
"hysteresisBound",
"(",
"5",
")",
",",
"periodic",
"(",
"6",
")",
",",
"andedWithValue",
"(",
"7",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition>This object specifies the mode of operation for this recording. The modes are defined as follows: Value Description other the recording mode of operation is not described in this standard, refer to the device manual. onChange trigger a recording when the object value referenced by recConfigCompareOID changes. The values of recConfigCompareValue and recConfigCompareValue2 are ignored in this mode. greaterThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes greater than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). smallerThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes less than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). hysteresisBound trigger a recording when the object value referenced by recConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of recConfigCompareValue and recConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent triggering of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent triggering of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic trigger a recording every x seconds, where x is defined by the value stored in recConfigCompareValue. The values stored in recConfigCompareValue2 and recConfigCompareOID are ignored in this mode. andedWithValue trigger a recording when the object value referenced by recConfigCompareOID ANDED with the value of recConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.97.1.3 \"",
"DEFVAL",
"{",
"onChange",
"}",
"::=",
"{",
"recConfigEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"other",
1
],
[
"onChange",
2
],
[
"greaterThanValue",
3
],
[
"smallerThanValue",
4
],
[
"hysteresisBound",
5
],
[
"periodic",
6
],
[
"andedWithValue",
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition>This object specifies the mode of operation for this recording. The modes are defined as follows: Value Description other the recording mode of operation is not described in this standard, refer to the device manual. onChange trigger a recording when the object value referenced by recConfigCompareOID changes. The values of recConfigCompareValue and recConfigCompareValue2 are ignored in this mode. greaterThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes greater than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). smallerThanValue trigger a recording when the object value referenced by recConfigCompareOID becomes less than the value of recConfigCompareValue for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). hysteresisBound trigger a recording when the object value referenced by recConfigCompareOID becomes less than or greater than the bound values. The lowerbound value is the lower value of recConfigCompareValue and recConfigCompareValue2; the upperbound value is the higher value of the two values. When the object value becomes greater than the upper bound value, subsequent triggering of upperbound conditions shall not occur until the object value becomes less than the lower bound value. When the object value becomes less than the lower bound value, subsequent triggering of lowerbound conditions shall not occur until the object value becomes greater than the upper bound value. periodic trigger a recording every x seconds, where x is defined by the value stored in recConfigCompareValue. The values stored in recConfigCompareValue2 and recConfigCompareOID are ignored in this mode. andedWithValue trigger a recording when the object value referenced by recConfigCompareOID ANDED with the value of recConfigCompareValue is NOT equal to zero for the time (tenth seconds) defined by recConfigCompareValue2 (zero means immediate logging). This allows monitoring of a specific bit; the condition becomes true anytime that any one of the selected bits become true. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.97.1.3"
],
null,
null,
null,
[
"DEFVAL",
"onChange"
]
]
}