Status in source: mandatory.
Names: rmcMLFlowBasedNoActivityTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rmcMLFlowBasedNoActivityTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"RmcMLFlowBasedNoActivityEntry",
"ACCESS",
"not-accessible",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"A table containing the configuration information for an entry in the Mainline Flow-based No Activity Table. The purpose of this table is to define the duration for the flow-based no activity diagnostic test. The duration will vary with the Average Station Flow Rate. Flow-based No Activity Threshold value in the first entry shall be the maximum threshold. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in this entry row and greater than the value in the following entry, then the Flow-based No Activity Duration in that entry shall be used. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in the last entry, then the Flow-based No Activity Duration of the last entry shall be used. If the value of the rmcAverageFlowRate-object is greater than the maximum value of the rmcFlowRateNoActivityThreshold-object in the table, then the Mainline Flow-based No Activity test shall be disabled. The first instance of the rmcFlowRateNoActivityThreshold-object whose value is zero indicates the end of the valid table contents. Rows prior to the end of the valid rows that contain a value of zero (0) for the rmcFlowBasedNoActivityDuration-object indicate that this row shall NOT be used for flow-based no activity testing. Additionally, the following rules shall be used when configuring this table: - All rmcFlowRateNoActivityThreshold-object entries in the table shall be decreasing for increasing indices. - All rmcFlowBasedNoActivityDuration-object entries in the table shall be non-decreasing for increasing indices. - if the value of the rmcNumFlowRateLanes-object is ‘0’, then the rmcFlowRateNoActivityDuration-object shall have a value of ‘0’. <Table Type> static. <Object Identifier> 1.3.6.1.4.1.1206.4.2.2.2.11\"",
"::=",
"{",
"rmcML",
"11",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"RmcMLFlowBasedNoActivityEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"A table containing the configuration information for an entry in the Mainline Flow-based No Activity Table. The purpose of this table is to define the duration for the flow-based no activity diagnostic test. The duration will vary with the Average Station Flow Rate. Flow-based No Activity Threshold value in the first entry shall be the maximum threshold. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in this entry row and greater than the value in the following entry, then the Flow-based No Activity Duration in that entry shall be used. If the value of the rmcAverageFlowRate-object is less than the value of the rmcFlowRateNoActivityThreshold-object in the last entry, then the Flow-based No Activity Duration of the last entry shall be used. If the value of the rmcAverageFlowRate-object is greater than the maximum value of the rmcFlowRateNoActivityThreshold-object in the table, then the Mainline Flow-based No Activity test shall be disabled. The first instance of the rmcFlowRateNoActivityThreshold-object whose value is zero indicates the end of the valid table contents. Rows prior to the end of the valid rows that contain a value of zero (0) for the rmcFlowBasedNoActivityDuration-object indicate that this row shall NOT be used for flow-based no activity testing. Additionally, the following rules shall be used when configuring this table: - All rmcFlowRateNoActivityThreshold-object entries in the table shall be decreasing for increasing indices. - All rmcFlowBasedNoActivityDuration-object entries in the table shall be non-decreasing for increasing indices. - if the value of the rmcNumFlowRateLanes-object is ‘0’, then the rmcFlowRateNoActivityDuration-object shall have a value of ‘0’. <Table Type> static. <Object Identifier> 1.3.6.1.4.1.1206.4.2.2.2.11"
],
null,
null,
null,
null
]
}
- NTCIP published standard MIB annexes (reviewed modules)
· Publisher's source file: NTCIP 1207 v02, Object Definitions for Ramp Meter Control (RMC) Units Published September 2014 — original PDF
· Official record
Module: N207v0214-MIB
See published definition above
Module imports
{'NTCIP': ['ramp'], 'RFC-1212': ['OBJECT-TYPE']}
Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.
Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.
Source data warning: The PDF prints an invalid ASN.1 module label (1207v0214-MIB). The derived transcription uses an equal-length internal parsing label; this is not an OID registration or an alteration of any numeric assignment. The original label and full PDF are retained.
Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP1207v0214hj.pdf — N207v0214-MIB (MIB transcription)
Related source files and packages:
Show more related files and packages