OID reference

rmcCmdSourcePriorityOrder

1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4

Description

Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual, communications, interconnect, timebase control, default; schemeICT -in decreasing order: manual, interconnect, communications, timebase control, default; schemeTCI -in decreasing order: man…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.2.3.1.3.1 (rmcMeterCfgEntry)
Node code
4
Node name
rmcCmdSourcePriorityOrder
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 2 3 1 3 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) ramp(2) rmcMeter(3) rmcMeterMain(1) rmcMeterCfgTable(3) rmcMeterCfgEntry(1) rmcCmdSourcePriorityOrder(4)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/2/3/1/3/1/4
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/2/3/1/3/1/4
  • /ISO/3/6/1/4/1/1206/4/2/2/3/1/3/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/ramp/rmcMeter/rmcMeterMain/rmcMeterCfgTable/rmcMeterCfgEntry/rmcCmdSourcePriorityOrder
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1schemeCIT
2schemeICT
3schemeTCI
4schemeTIC
5schemeCTI
6schemeITC

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In N207v0214-MIB, the row index rmcMeterNumber is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4.<rmcMeterNumber>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

rmcCmdSourcePriorityOrder · mandatory

rmcCmdSourcePriorityOrder        OBJECT-TYPE
SYNTAX   INTEGER {
   schemeCIT (1),
   schemeICT (2),
   schemeTCI (3),
   schemeTIC (4),
   schemeCTI (5),
   schemeITC (6)
   }
ACCESS   read-write
STATUS   mandatory



                                                                                        

                 
       

DESCRIPTION
"Indicates the active command source priority order for this metered lane.
The values are:
schemeCIT -in decreasing order: manual, communications, interconnect,
    timebase control, default;
schemeICT -in decreasing order: manual, interconnect, communications,
    timebase control, default;
schemeTCI -in decreasing order: manual, timebase control, communications,
    interconnect, default;
schemeTIC -in decreasing order: manual, timebase control, interconnect,
    communications, default;
schemeCTI -in decreasing order: manual, communications, timebase control,
    interconnect, default;
schemeITC -in decreasing order: manual, interconnect, timebase control,
    communications, default.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4"
REFERENCE
"See Clause A.3"
::={ rmcMeterCfgEntry 4 }

rmcCmdSourcePriorityOrder · mandatory

rmcCmdSourcePriorityOrder OBJECT-TYPE
SYNTAX INTEGER {
schemeCIT (1),
schemeICT (2),
schemeTCI (3),
schemeTIC (4),
schemeCTI (5),
schemeITC (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the active command source priority order for this metered lane. The
values are:
schemeCIT -in decreasing order: manual - communications - interconnect -
timebase control - default;
schemeICT -in decreasing order: manual - interconnect - communications-
timebase control - default
schemeTCI -in decreasing order: manual - timebase control - communications -
interconnect -default;
schemeTIC -in decreasing order: manual - timebase control - interconnect -
communications-default
schemeCTI -in decreasing order: manual - communications- timebase control-
interconnect - default;
schemeITC -in decreasing order: manual - interconnect- timebase control -
communications - default"
REFERENCE
"See Clause A.3"
::={ rmcMeterCfgEntry 4 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual, communications, interconnect, timebase control, default; schemeICT -in decreasing order: manual, interconnect, communications, timebase control, default; schemeTCI -in decreasing order: manual, timebase control, communications, interconnect, default; schemeTIC -in decreasing order: manual, timebase control, interconnect, communications, default; schemeCTI -in decreasing order: manual, communications, timebase control, interconnect, default; schemeITC -in decreasing order: manual, interconnect, timebase control, communications, default. <Object Identifier> 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual - communications - interconnect - timebase control - default; schemeICT -in decreasing order: manual - interconnect - communications- timebase control - default schemeTCI -in decreasing order: manual - timebase control - communications - interconnect -default; schemeTIC -in decreasing order: manual - timebase control - interconnect - communications-default schemeCTI -in decreasing order: manual - communications- timebase control- interconnect - default; schemeITC -in decreasing order: manual - interconnect- timebase control - communications - default

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

rmcCmdSourcePriorityOrder · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: rmcCmdSourcePriorityOrder

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rmcCmdSourcePriorityOrder",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "schemeCIT",
    "(",
    "1",
    ")",
    ",",
    "schemeICT",
    "(",
    "2",
    ")",
    ",",
    "schemeTCI",
    "(",
    "3",
    ")",
    ",",
    "schemeTIC",
    "(",
    "4",
    ")",
    ",",
    "schemeCTI",
    "(",
    "5",
    ")",
    ",",
    "schemeITC",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual, communications, interconnect, timebase control, default; schemeICT -in decreasing order: manual, interconnect, communications, timebase control, default; schemeTCI -in decreasing order: manual, timebase control, communications, interconnect, default; schemeTIC -in decreasing order: manual, timebase control, interconnect, communications, default; schemeCTI -in decreasing order: manual, communications, timebase control, interconnect, default; schemeITC -in decreasing order: manual, interconnect, timebase control, communications, default. <Object Identifier> 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4\"",
    "REFERENCE",
    "\"See Clause A.3\"",
    "::=",
    "{",
    "rmcMeterCfgEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "schemeCIT",
            1
          ],
          [
            "schemeICT",
            2
          ],
          [
            "schemeTCI",
            3
          ],
          [
            "schemeTIC",
            4
          ],
          [
            "schemeCTI",
            5
          ],
          [
            "schemeITC",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual, communications, interconnect, timebase control, default; schemeICT -in decreasing order: manual, interconnect, communications, timebase control, default; schemeTCI -in decreasing order: manual, timebase control, communications, interconnect, default; schemeTIC -in decreasing order: manual, timebase control, interconnect, communications, default; schemeCTI -in decreasing order: manual, communications, timebase control, interconnect, default; schemeITC -in decreasing order: manual, interconnect, timebase control, communications, default. <Object Identifier> 1.3.6.1.4.1.1206.4.2.2.3.1.3.1.4"
    ],
    [
      "REFERENCE",
      "See Clause A.3"
    ],
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

rmcCmdSourcePriorityOrder · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: rmcCmdSourcePriorityOrder

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rmcCmdSourcePriorityOrder",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "schemeCIT",
    "(",
    "1",
    ")",
    ",",
    "schemeICT",
    "(",
    "2",
    ")",
    ",",
    "schemeTCI",
    "(",
    "3",
    ")",
    ",",
    "schemeTIC",
    "(",
    "4",
    ")",
    ",",
    "schemeCTI",
    "(",
    "5",
    ")",
    ",",
    "schemeITC",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual - communications - interconnect - timebase control - default; schemeICT -in decreasing order: manual - interconnect - communications- timebase control - default schemeTCI -in decreasing order: manual - timebase control - communications - interconnect -default; schemeTIC -in decreasing order: manual - timebase control - interconnect - communications-default schemeCTI -in decreasing order: manual - communications- timebase control- interconnect - default; schemeITC -in decreasing order: manual - interconnect- timebase control - communications - default\"",
    "REFERENCE",
    "\"See Clause A.3\"",
    "::=",
    "{",
    "rmcMeterCfgEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "schemeCIT",
            1
          ],
          [
            "schemeICT",
            2
          ],
          [
            "schemeTCI",
            3
          ],
          [
            "schemeTIC",
            4
          ],
          [
            "schemeCTI",
            5
          ],
          [
            "schemeITC",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Indicates the active command source priority order for this metered lane. The values are: schemeCIT -in decreasing order: manual - communications - interconnect - timebase control - default; schemeICT -in decreasing order: manual - interconnect - communications- timebase control - default schemeTCI -in decreasing order: manual - timebase control - communications - interconnect -default; schemeTIC -in decreasing order: manual - timebase control - interconnect - communications-default schemeCTI -in decreasing order: manual - communications- timebase control- interconnect - default; schemeITC -in decreasing order: manual - interconnect- timebase control - communications - default"
    ],
    [
      "REFERENCE",
      "See Clause A.3"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (40)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.1 rmcMeterNumber00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.2 rmcDependGroupNumber00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.3 rmcDependGroupSeqNumber00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.5 rmcDemandErraticCount00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.6 rmcDemandMaxPresence00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.7 rmcDemandNoActivity00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.8 rmcMinMeterTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.9 rmcMinNonMeterTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.10 rmcAbsoluteMinMeterRate00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.11 rmcAbsoluteMaxMeterRate00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.12 rmcSystemMinMeterRate00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.13 rmcSystemMaxMeterRate00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.14 rmcStartAlert00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.15 rmcStartWarning00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.16 rmcStartGreen00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.17 rmcStartGapTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.18 rmcStartGapQueueDetectorNum00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.19 rmcStartYellow00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.20 rmcStartRed00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.21 rmcMinRed00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.22 rmcRedViolationClearance00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.23 rmcRedViolationAdjust00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.24 rmcMinGreen00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.25 rmcMaxGreen00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.26 rmcYellow00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.27 rmcShortStopTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.28 rmcShortStopOccupancy00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.29 rmcShortStopQueueDetectorNum00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.30 rmcLongStopTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.31 rmcDemandGap00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.32 rmcDemandRed00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.33 rmcShutNormalRate00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.34 rmcShutWarning00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.35 rmcShutTime00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.36 rmcPostMeterGreen00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.37 rmcQueueViolationFlag00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.38 rmcQueueShutdownFlag00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.39 rmcQueueAdjustUsage00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.40 rmcDemandDependMaxPresence00
1.3.6.1.4.1.1206.4.2.2.3.1.3.1.41 rmcDemandDependNoActivity00