Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rmcImplementCommandSource",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"manual",
"(",
"1",
")",
",",
"communications",
"(",
"2",
")",
",",
"interconnect",
"(",
"3",
")",
",",
"timebaseControl",
"(",
"4",
")",
",",
"default",
"(",
"5",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Indicates the command source that currently controls this metered lane. The values are: manual - the metered lane is currently controlled locally at the site. communications - the metered lane is currently controlled by the central system. This usually means that the entire RMC is controlled centrally. interconnect - the metered lane is currently controlled by an on-street master controller. timebaseControl - the metered lane is currently controlled using values as selected via the Timebase Control Action table. default - indicates that the metered lane is currently controlled using default settings.\"",
"REFERENCE",
"\"See Clause A.3\"",
"::=",
"{",
"rmcMeterStatEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"manual",
1
],
[
"communications",
2
],
[
"interconnect",
3
],
[
"timebaseControl",
4
],
[
"default",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Indicates the command source that currently controls this metered lane. The values are: manual - the metered lane is currently controlled locally at the site. communications - the metered lane is currently controlled by the central system. This usually means that the entire RMC is controlled centrally. interconnect - the metered lane is currently controlled by an on-street master controller. timebaseControl - the metered lane is currently controlled using values as selected via the Timebase Control Action table. default - indicates that the metered lane is currently controlled using default settings."
],
[
"REFERENCE",
"See Clause A.3"
],
null,
null,
null
]
}