Description

Indicates the method used to select the Brightness Level. Photocell indicates that the Brightness Level is based on photocell status. Timer indicates that the Brightness Level is set by an internal timer. Manual indicates that the Brightness Level must be changed via the dmsIllumManLevel- object. When switching to man…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.3.7 (illum)
Node code
1
Node name
dmsIllumControl
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.3.7.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.3.7.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 3 7 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) illum(7) dmsIllumControl(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) illum(7) dmsIllumControl(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/3/7/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/3/7/1
  • /ISO/3/6/1/4/1/1206/4/2/3/7/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/fontDefinition/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/dms/illum/dmsIllumControl
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/fontDefinition/illum/dmsIllumControl
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory, current
Default value
photocell

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Variant 2 — ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
photocell

Variant 3 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
photocell

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it. Notes below names come from selected MIB definitions.

ValueName and source notesSource variants
1other
deprecated
1, 2, 3
2photocell1, 2, 3
3timer1, 2, 3
4manual
obsolete; retired
1, 2, 3
5manualDirect2, 3
6manualIndexed2, 3

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.3.7.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

dmsIllumControl · mandatory

dmsIllumControl OBJECT-TYPE
SYNTAX           INTEGER {
                          other (1),
                          photocell (2),
                          timer (3),
                          manual (4)
                          }
ACCESS           read-write
STATUS           mandatory
DESCRIPTION “Indicates the method used to select the Brightness Level. Photocell indicates that the
Brightness Level is based on photocell status. Timer indicates that the Brightness Level is set by an
internal timer. Manual indicates that the Brightness Level must be changed via the dmsIllumManLevel-
object. When switching to manual mode from any other mode, the current brightness level shall
automatically be loaded into the dmsIllumManLevel object.”
::= {illum 1}

dmsIllumControl · unconfirmed

dmsIllumControl  OBJECT-TYPE 
SYNTAX      INTEGER {
                 other (1),         -- deprecated
                 photocell (2),
                 timer (3),
                 manual (4),        -- obsolete 
                 manualDirect (5),
                 manualIndexed (6) } 
MAX-ACCESS  read-write 
STATUS      current  
DESCRIPTION  
"<Definition> Indicates the method used to select the Brightness Level.
A DMS may subrange the values supported, as indicated.
<Format>
  other (1) - indicates that the Brightness Level is based on a 
     mechanism not defined by this standard; see manufacturer 
     documentation. This mode is DEPRECATED.
  photocell (2) - indicates that the Brightness Level is based on 
     photocell status. Support for this mode shall be supported if 
     user need 2.5.1.5 is selected.
  timer (3) - indicates that the Brightness Level is set by an internal 
     timer. The details of this timer are not defined by this standard.
  manual (4) - indicates that the Brightness Level must be changed via 
     the dmsIllumManLevel object. This mode is OBSOLETE.
  manualDirect (5) - indicates that a user can change the brightness output 
     to any of the brightness levels (dmsIllumNumBrightLevels) supported by 
     the sign. This is not the same as the number of brightness levels 
     defined within the table of the dmsIllumBrightnessValues object. 
  manualIndexed (6) - indicates that a user can change the brightness output
     to any of the rows defined within the table of the
     dmsIllumBrightnessValues object. 
The DMS shall support manualDirect, manualIndex, or both. Support for all 
other values is optional.

When switching to any of the manual modes (manual, manualDirect, 
manualIndexed) from any other mode, the current brightness level shall 
automatically be loaded into the dmsIllumManLevel object.

<Informative> In v02, the enumerated values of 'other' and 'manual' were 
deprecated to improve interoperability. In v04, the value of 'manual' was 
made obsolete.
<Parameter Type> Configuration
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
DEFVAL  {photocell} 
::= { illum 1 }

dmsIllumControl · mandatory

dmsIllumControl OBJECT-TYPE
SYNTAX INTEGER {
                     other (1),
                     photocell (2),
                     timer (3),
                     manual (4), -- retired
                     manualDirect (5),
                     manualIndexed (6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Indicates the method used to select the Brightness Level.



                                                                                        

Page 182                                                           NTCIP 1203 v02.35


  A DMS may subrange the values supported, as indicated.
  other (1) - indicates that the Brightness Level is based on a
     mechanism not defined by this standard; see manufacturer
     documentation.
  photocell (2) - indicates that the Brightness Level is based on
     photocell status. Support for this mode shall be supported if
     Requirement 3.4.2.5.4 is selected.
  timer (3) - indicates that the Brightness Level is set by an internal
     timer. The details of this timer are not defined by this standard.
  manual (4) - indicates that the Brightness Level must be changed via
     the dmsIllumManLevel object. This mode is DEPRECATED.
  manualDirect (5) - indicates that a user can directly and manually
     change the brightness output to any of the brightness levels
     supported by the sign. This is not the same as the number of brightness
     levels defined within the table of the dmsIllumBrightnessValues object.
     This mode is mandatory, if this is the manual mode that the DMS
     supports.
  manualIndexed (6) - indicates that a user can directly and manually change
     the brightness output to any of the rows defined within the table of
     the dmsIllumBrightnessValues object. This mode is mandatory, if this is
     the manual mode that the DMS supports.
The DMS must support either one of the manualXxx modes.

When switching to any of the manual modes (manual, manualDirect,
manualIndexed) from any other mode, the current brightness level shall
automatically be loaded into the dmsIllumManLevel object.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
DEFVAL {photocell}
::= { illum 1 }

dmsIllumControl · mandatory

dmsIllumControl  OBJECT-TYPE
SYNTAX  INTEGER {
                 other (1),
                 photocell (2),
                 timer (3),
                 manual (4), -- retired
                 manualDirect (5),
                 manualIndexed (6) }
ACCESS  read-write
STATUS  mandatory
DESCRIPTION 
"<Definition> Indicates the method used to select the Brightness Level.
  A DMS may subrange the values supported, as indicated.
  other (1) - indicates that the Brightness Level is based on a 
     mechanism not defined by this standard; see manufacturer 
     documentation.
  photocell (2) - indicates that the Brightness Level is based on 
     photocell status. Support for this mode shall be supported if 
     Requirement 3.4.2.5.4 is selected.
  timer (3) - indicates that the Brightness Level is set by an internal 
     timer. The details of this timer are not defined by this standard.
  manual (4) - indicates that the Brightness Level must be changed via 
     the dmsIllumManLevel object. This mode is DEPRECATED.
manualDirect (5) - indicates that a user can change the brightness output to
   any of the brightness levels supported by the sign. This is not the same
   as the number of brightness levels defined within the table of the
   dmsIllumBrightnessValues object. This mode is mandatory, if this is the
   manual mode that the DMS supports.
manualIndexed (6) - indicates that a user can change the brightness output
   to any of the rows defined within the table of the
   dmsIllumBrightnessValues object. This mode is mandatory, if this is 
     the manual mode that the DMS supports.
The DMS must support either one of the manualXxx modes.

When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
DEFVAL  {photocell}
::= { illum 1 }

dmsIllumControl · mandatory

dmsIllumControl OBJECT-TYPE
SYNTAX INTEGER {
                    other (1),
                    photocell (2),
                    timer (3),
                    manual (4), -- retired
                    manualDirect (5),
                    manualIndexed (6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Indicates the method used to select the Brightness Level.
   A DMS may subrange the values supported, as indicated.
   other (1) - indicates that the Brightness Level is based on a
      mechanism not defined by this standard; see manufacturer
      documentation.
   photocell (2) - indicates that the Brightness Level is based on
      photocell status. Support for this mode shall be supported if
      Requirement 3.4.2.5.4 is selected.
   timer (3) - indicates that the Brightness Level is set by an internal
      timer. The details of this timer are not defined by this standard.
   manual (4) - indicates that the Brightness Level must be changed via
      the dmsIllumManLevel object. This mode is DEPRECATED.
   manualDirect (5) - indicates that a user can change the brightness output
to
      any of the brightness levels supported by the sign. This is not the same
      as the number of brightness levels defined within the table of the
      dmsIllumBrightnessValues object. This mode is mandatory, if this is the
      manual mode that the DMS supports.
   manualIndexed (6) - indicates that a user can change the brightness output
      to any of the rows defined within the table of the
      dmsIllumBrightnessValues object. This mode is mandatory, if this is
      the manual mode that the DMS supports.
The DMS must support either one of the manualXxx modes.

When switching to any of the manual modes (manual, manualDirect,
manualIndexed) from any other mode, the current brightness level shall
automatically be loaded into the dmsIllumManLevel object.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
DEFVAL {photocell}
::= { illum 1 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Indicates the method used to select the Brightness Level. Photocell indicates that the Brightness Level is based on photocell status. Timer indicates that the Brightness Level is set by an internal timer. Manual indicates that the Brightness Level must be changed via the dmsIllumManLevel- object. When switching to manual mode from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. <Format> other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. This mode is DEPRECATED. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if user need 2.5.1.5 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is OBSOLETE. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels (dmsIllumNumBrightLevels) supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. The DMS shall support manualDirect, manualIndex, or both. Support for all other values is optional. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Informative> In v02, the enumerated values of 'other' and 'manual' were deprecated to improve interoperability. In v04, the value of 'manual' was made obsolete. <Parameter Type> Configuration <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 3

<Definition> Indicates the method used to select the Brightness Level. Page 182 NTCIP 1203 v02.35 A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can directly and manually change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can directly and manually change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

dmsIllumControl · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: dmsIllumControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsIllumControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "photocell",
    "(",
    "2",
    ")",
    ",",
    "timer",
    "(",
    "3",
    ")",
    ",",
    "manual",
    "(",
    "4",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "“",
    "Indicates",
    "the",
    "method",
    "used",
    "to",
    "select",
    "the",
    "Brightness",
    "Level",
    ".",
    "Photocell",
    "indicates",
    "that",
    "the",
    "Brightness",
    "Level",
    "is",
    "based",
    "on",
    "photocell",
    "status",
    ".",
    "Timer",
    "indicates",
    "that",
    "the",
    "Brightness",
    "Level",
    "is",
    "set",
    "by",
    "an",
    "internal",
    "timer",
    ".",
    "Manual",
    "indicates",
    "that",
    "the",
    "Brightness",
    "Level",
    "must",
    "be",
    "changed",
    "via",
    "the",
    "dmsIllumManLevel-",
    "object",
    ".",
    "When",
    "switching",
    "to",
    "manual",
    "mode",
    "from",
    "any",
    "other",
    "mode",
    ",",
    "the",
    "current",
    "brightness",
    "level",
    "shall",
    "automatically",
    "be",
    "loaded",
    "into",
    "the",
    "dmsIllumManLevel",
    "object",
    ".",
    "”",
    "::=",
    "{",
    "illum",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "photocell",
            2
          ],
          [
            "timer",
            3
          ],
          [
            "manual",
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Indicates the method used to select the Brightness Level. Photocell indicates that the Brightness Level is based on photocell status. Timer indicates that the Brightness Level is set by an internal timer. Manual indicates that the Brightness Level must be changed via the dmsIllumManLevel- object. When switching to manual mode from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2ITE public NTCIP working repository MIBs1 record · 1 source

Description 2

dmsIllumControl · unconfirmedITE public NTCIP working repository MIBs1 source

Status in source: unconfirmed.

Names: dmsIllumControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsIllumControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "photocell",
    "(",
    "2",
    ")",
    ",",
    "timer",
    "(",
    "3",
    ")",
    ",",
    "manual",
    "(",
    "4",
    ")",
    ",",
    "manualDirect",
    "(",
    "5",
    ")",
    ",",
    "manualIndexed",
    "(",
    "6",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. <Format> other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. This mode is DEPRECATED. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if user need 2.5.1.5 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is OBSOLETE. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels (dmsIllumNumBrightLevels) supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. The DMS shall support manualDirect, manualIndex, or both. Support for all other values is optional. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Informative> In v02, the enumerated values of 'other' and 'manual' were deprecated to improve interoperability. In v04, the value of 'manual' was made obsolete. <Parameter Type> Configuration <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1\"",
    "DEFVAL",
    "{",
    "photocell",
    "}",
    "::=",
    "{",
    "illum",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "photocell",
            2
          ],
          [
            "timer",
            3
          ],
          [
            "manual",
            4
          ],
          [
            "manualDirect",
            5
          ],
          [
            "manualIndexed",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. <Format> other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. This mode is DEPRECATED. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if user need 2.5.1.5 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is OBSOLETE. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels (dmsIllumNumBrightLevels) supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. The DMS shall support manualDirect, manualIndex, or both. Support for all other values is optional. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Informative> In v02, the enumerated values of 'other' and 'manual' were deprecated to improve interoperability. In v04, the value of 'manual' was made obsolete. <Parameter Type> Configuration <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "photocell"
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1203 — NTCIP1203-Dms.mib

    Module: NTCIP1203-Dms

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'StorageType', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO26048-1-Srsa': ['fdSrsaTypeCode', 'fdSrsaPortIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ISO26048-1-Global-TC': ['ITSDirection', 'ITSInteger8', 'ITSLatitude84', 'ITSLongitude84', 'ITSBitmap'], 'TRANSPORT-ADDRESS-MIB': ['TransportAddressType', 'TransportAddress'], 'NTCIP8004-Transportation': ['NtcipOwnerString', 'NtcipIntegerBitmap8', 'NtcipIntegerBitmap16', 'NtcipTwoColors', 'devices']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Published module-root disagreement: dms has an SMI assignment resolving to 1.3.6.1.4.1.1206.4.2.6, while its DESCRIPTION explicitly prints 1.3.6.1.4.1.1206.4.2.3. All dependent assignments from this module require verification. No root number has been silently corrected.

    Source data warning: Published source disagreement: this literal SMI assignment resolves to 1.3.6.1.4.1.1206.4.2.6.7.1, but its DESCRIPTION explicitly lists 1.3.6.1.4.1.1206.4.2.3.7.1. Both published numeric claims are retained as unconfirmed evidence. Neither value is presented as a verified correction or an independently confirmed registration; consult the original file and the applicable standard edition.

    · Download NTCIP-1203 — NTCIP1203-Dms.mib
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

dmsIllumControl · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: dmsIllumControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsIllumControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "photocell",
    "(",
    "2",
    ")",
    ",",
    "timer",
    "(",
    "3",
    ")",
    ",",
    "manual",
    "(",
    "4",
    ")",
    ",",
    "manualDirect",
    "(",
    "5",
    ")",
    ",",
    "manualIndexed",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the method used to select the Brightness Level. Page 182 NTCIP 1203 v02.35 A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can directly and manually change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can directly and manually change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1\"",
    "DEFVAL",
    "{",
    "photocell",
    "}",
    "::=",
    "{",
    "illum",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "photocell",
            2
          ],
          [
            "timer",
            3
          ],
          [
            "manual",
            4
          ],
          [
            "manualDirect",
            5
          ],
          [
            "manualIndexed",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the method used to select the Brightness Level. Page 182 NTCIP 1203 v02.35 A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can directly and manually change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can directly and manually change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "photocell"
    ]
  ]
}
Records for description 4ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 4

dmsIllumControl · mandatoryITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: dmsIllumControl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsIllumControl",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "photocell",
    "(",
    "2",
    ")",
    ",",
    "timer",
    "(",
    "3",
    ")",
    ",",
    "manual",
    "(",
    "4",
    ")",
    ",",
    "manualDirect",
    "(",
    "5",
    ")",
    ",",
    "manualIndexed",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1\"",
    "DEFVAL",
    "{",
    "photocell",
    "}",
    "::=",
    "{",
    "illum",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "photocell",
            2
          ],
          [
            "timer",
            3
          ],
          [
            "manual",
            4
          ],
          [
            "manualDirect",
            5
          ],
          [
            "manualIndexed",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Indicates the method used to select the Brightness Level. A DMS may subrange the values supported, as indicated. other (1) - indicates that the Brightness Level is based on a mechanism not defined by this standard; see manufacturer documentation. photocell (2) - indicates that the Brightness Level is based on photocell status. Support for this mode shall be supported if Requirement 3.4.2.5.4 is selected. timer (3) - indicates that the Brightness Level is set by an internal timer. The details of this timer are not defined by this standard. manual (4) - indicates that the Brightness Level must be changed via the dmsIllumManLevel object. This mode is DEPRECATED. manualDirect (5) - indicates that a user can change the brightness output to any of the brightness levels supported by the sign. This is not the same as the number of brightness levels defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. manualIndexed (6) - indicates that a user can change the brightness output to any of the rows defined within the table of the dmsIllumBrightnessValues object. This mode is mandatory, if this is the manual mode that the DMS supports. The DMS must support either one of the manualXxx modes. When switching to any of the manual modes (manual, manualDirect, manualIndexed) from any other mode, the current brightness level shall automatically be loaded into the dmsIllumManLevel object. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.1"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "photocell"
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP_1203 — v03/1203v03A-06g.mib

    Module: NTCIP1203-v0305

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['OwnerString', 'dms']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP_1203 — v03/1203v03A-06g.mib
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1203 v03, Object Definitions for Dynamic Message Signs (DMS) Published September 2014 — original PDF · Official record

    Module: NTCIP1203-v03-05

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'NTCIP8004': ['OwnerString', 'dms'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: The PDF prints an invalid ASN.1 module label (NTCIP1203 v03.05). The derived transcription uses an equal-length internal parsing label; this is not an OID registration or an alteration of any numeric assignment. The original label and full PDF are retained.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1203v03f.pdf — NTCIP1203-v03-05 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.3.7.2 dmsIllumMaxPhotocellLevel00
1.3.6.1.4.1.1206.4.2.3.7.3 dmsIllumPhotocellLevelStatus00
1.3.6.1.4.1.1206.4.2.3.7.4 dmsIllumNumBrightLevels00
1.3.6.1.4.1.1206.4.2.3.7.5 dmsIllumBrightLevelStatus00
1.3.6.1.4.1.1206.4.2.3.7.6 dmsIllumManLevel00
1.3.6.1.4.1.1206.4.2.3.7.7 dmsIllumBrightnessValues00
1.3.6.1.4.1.1206.4.2.3.7.8 dmsIllumBrightnessValuesError00
1.3.6.1.4.1.1206.4.2.3.7.9 dmsIllumLightOutputStatus00