Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ptsOperationalModeV3",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"1",
")",
",",
"manual",
"(",
"2",
")",
",",
"automatic",
"(",
"3",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition>Indicates the operational mode of the Pavement Treatment System. When in the 'off' state, the PTS shall not trigger the sprayer even if commanded to do so and shall always be inactive. The PTS shall transition to the requested operational mode, upon request. When in the 'automatic' state, the PTS shall monitor conditions and trigger the sprayer based on a manufacturer specific algorithm. The algorithm shall only consider input from the detectors selected in the ptsMonitoringDetectors object. The PTS shall also trigger the sprayer if commanded to do so via the ptsCommandStateV3 object. The PTS shall transition to the requested operational mode, upon request. When in the 'manual' state, the PTS shall trigger the sprayer if commanded to do so via the ptsCommandStateV3 object. The PTS shall transition to the requested operational mode, upon request. <SetConstraint>always <DescriptiveName>PTS.operationalMode.code <Valid Value Rule> off When set to this value the ESS will not trigger the bridge sprayer manual When set to this value the ESS will only trigger the bridge sprayer when manually commanded to do so (e.g., see ptsCommandStateV3). automatic When set to this value the ESS will trigger the bridge sprayer when manually commanded to do so or when the internal algorithm determines that the sprayer should be triggered. <Data Concept Type>Data Element\"",
"::=",
"{",
"essNtcipTreatment",
"18",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
1
],
[
"manual",
2
],
[
"automatic",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition>Indicates the operational mode of the Pavement Treatment System. When in the 'off' state, the PTS shall not trigger the sprayer even if commanded to do so and shall always be inactive. The PTS shall transition to the requested operational mode, upon request. When in the 'automatic' state, the PTS shall monitor conditions and trigger the sprayer based on a manufacturer specific algorithm. The algorithm shall only consider input from the detectors selected in the ptsMonitoringDetectors object. The PTS shall also trigger the sprayer if commanded to do so via the ptsCommandStateV3 object. The PTS shall transition to the requested operational mode, upon request. When in the 'manual' state, the PTS shall trigger the sprayer if commanded to do so via the ptsCommandStateV3 object. The PTS shall transition to the requested operational mode, upon request. <SetConstraint>always <DescriptiveName>PTS.operationalMode.code <Valid Value Rule> off When set to this value the ESS will not trigger the bridge sprayer manual When set to this value the ESS will only trigger the bridge sprayer when manually commanded to do so (e.g., see ptsCommandStateV3). automatic When set to this value the ESS will trigger the bridge sprayer when manually commanded to do so or when the internal algorithm determines that the sprayer should be triggered. <Data Concept Type>Data Element"
],
null,
null,
null,
null
]
}