Status in source: mandatory.
Names: essLineVolts
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"essLineVolts",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition>Indicates the voltage measured on the incoming power line for the controller. The value reported indicates one-half of the actual voltage; thus, this object indicates a value of 55 when the voltage is 110 Vrms. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., either is not supported or has a value of 255) and the essBatteryStatus object shall indicate the status of the batteries. <DescriptiveName>ESS.lineVolts:quantity <Valid Value Rule>Values 0 through 254 shall indicate valid values. The value 254 shall mean a voltage of 508 Vrms or greater. The value of 255 shall indicate an error condition or missing value. <Data Concept Type>Data Element <Unit>2 Volts Root Mean Squared (Vrms) (i.e., the value reported shall be one-half the actual voltage). <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.2.15.3\"",
"::=",
"{",
"essNtcipInstrumentation",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition>Indicates the voltage measured on the incoming power line for the controller. The value reported indicates one-half of the actual voltage; thus, this object indicates a value of 55 when the voltage is 110 Vrms. This object shall only be used to indicate A/C power conditions. If the line power is DC, this object shall not apply (i.e., either is not supported or has a value of 255) and the essBatteryStatus object shall indicate the status of the batteries. <DescriptiveName>ESS.lineVolts:quantity <Valid Value Rule>Values 0 through 254 shall indicate valid values. The value 254 shall mean a voltage of 508 Vrms or greater. The value of 255 shall indicate an error condition or missing value. <Data Concept Type>Data Element <Unit>2 Volts Root Mean Squared (Vrms) (i.e., the value reported shall be one-half the actual voltage). <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.2.15.3"
],
null,
null,
null,
null
]
}
- ITE public NTCIP working repository MIBs
· Publisher's source file: NTCIP-1204 — NTCIP1204-Ess.mib
Module: NTCIP1204-v04
See published definition above
Module imports
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['ess', 'OerString']}
Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.
Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP-1204 — NTCIP1204-Ess.mib
- NTCIP published standard MIB annexes (reviewed modules)
· Publisher's source file: NTCIP 1204 v0426, National Transportation Communications for ITS Protocol Environmental Sensor Station (ESS) Interface Protocol — original PDF
· Official record
Module: NTCIP1204-v04
See published definition above
Module imports
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['ess', 'OerString']}
Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.
Source data warning: The published normative SMI section omits its module END. The derived parser boundary is placed immediately before section 5.17, whose text explicitly says its items are not SNMP Objects. No declaration or numeric arc is added; the complete PDF is authoritative.
Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004v02. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP-1204v0426b-2021_AsPublished.pdf — NTCIP1204-v04 (MIB transcription)
Related source files and packages: