Status in source: mandatory.
Names: precipitationSensorModelInformationV4
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"precipitationSensorModelInformationV4",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition>A reference to the row in the Module Table (See NTCIP 1201) that indicates the manufacturer, model, and version number of the precipitation sensor. <DescriptiveName>PrecipitationSensor.modelInformation:identifier <Valid Value Rule>The value of zero indicates that this information is not available. <Data Concept Type>Data Element <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.2.6.14.1.6\"",
"::=",
"{",
"precipitationSensorEntry",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition>A reference to the row in the Module Table (See NTCIP 1201) that indicates the manufacturer, model, and version number of the precipitation sensor. <DescriptiveName>PrecipitationSensor.modelInformation:identifier <Valid Value Rule>The value of zero indicates that this information is not available. <Data Concept Type>Data Element <Object Identifier> 1.3.6.1.4.1.1206.4.2.5.2.6.14.1.6"
],
null,
null,
null,
null
]
}
- ITE public NTCIP working repository MIBs
· Publisher's source file: NTCIP-1204 — NTCIP1204-Ess.mib
Module: NTCIP1204-v04
See published definition above
Module imports
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['ess', 'OerString']}
Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.
Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP-1204 — NTCIP1204-Ess.mib