Status in source: optional.
Names: dcmIOParamTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dcmIOParamTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"DcmIOParamEntry",
"ACCESS",
"not-accessible",
"STATUS",
"optional",
"DESCRIPTION",
"\"This table defines parameters that can be applied to each IO channel to allow processing and adjustment of that IO channel. There can be multiple rows within this table for each logical IO. The indexing of this table will not be sequential. If an application tries to define more rows than the device will allow, an application error code of ‘exceeded max number of rows allowed’ shall be set. This is a double-indexed table. The table can be managed thru dcmIOParamRowAdmin object. If an attempt is made to set a parameter of an IO channel and the IO board associated with the IO channel can only set the parameter at a board level, all IO channels of that type (which have been entered into this table) on that IO board will be set to the specified value. It is up to the application to re-read this table to determine if any of the requested parameters have been changed. Conversely, if it is possible to access each IO channel within a board then each IO channel has to be set individually. Note that all IO channels may not require any parameters set and some IO channels may require multiple parameters set.\"",
"::=",
"{",
"dcmDeviceSetup",
"13",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"DcmIOParamEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"optional"
],
[
"DESCRIPTION",
"This table defines parameters that can be applied to each IO channel to allow processing and adjustment of that IO channel. There can be multiple rows within this table for each logical IO. The indexing of this table will not be sequential. If an application tries to define more rows than the device will allow, an application error code of ‘exceeded max number of rows allowed’ shall be set. This is a double-indexed table. The table can be managed thru dcmIOParamRowAdmin object. If an attempt is made to set a parameter of an IO channel and the IO board associated with the IO channel can only set the parameter at a board level, all IO channels of that type (which have been entered into this table) on that IO board will be set to the specified value. It is up to the application to re-read this table to determine if any of the requested parameters have been changed. Conversely, if it is possible to access each IO channel within a board then each IO channel has to be set individually. Note that all IO channels may not require any parameters set and some IO channels may require multiple parameters set."
],
null,
null,
null,
null
]
}
- NTCIP published standard MIB annexes (reviewed modules)
· Publisher's source file: NTCIP 1206:2005, Object Definitions for Data Collection and Monitoring (DCM) Devices Published November 2005 — original PDF
· Official record
Module: DCM-MIB1
See published definition above
Module imports
{'TMIB-II': ['devices'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter']}
Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.
Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.
Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.
Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.
Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB-II. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP1206v0123f.pdf — DCM-MIB1 (MIB transcription)
Related source files and packages:
Show more related files and packages
- NTCIP published standard MIB annexes (reviewed modules)
· Publisher's source file: NTCIP 1206:2005, Object Definitions for Daqta Collection and Monitoring (DCM) Devices Published November 2005 (superceded by NTCIP 1206 v02) — original PDF
· Official record
Module: DCM-MIB1
Same published definition
Module imports
{'TMIB-II': ['devices'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter']}
Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.
Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.
Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.
Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.
Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB-II. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.
· Download NTCIP1206v0123f-1.pdf — DCM-MIB1 (MIB transcription)
Related source files and packages: