OID reference

dcmReset

1.3.6.1.4.1.1206.4.2.9.3.1

Description

indicates the different types of resets that may be issued to the dcm device. The values and their meaning are: 1=Other 2=Hard Reset - (restart program, reset comms, clear all user settings, reset sensor boards, reset keyboard/display, reset cpu program memory, does not clear data files, resets to all factory defaults…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.9.3 (dcmOpsStatus)
Node code
1
Node name
dcmReset
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.9.3.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.9.3.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 9 3 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dcm(9) dcmOpsStatus(3) dcmReset(1)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/9/3/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/9/3/1
  • /ISO/3/6/1/4/1/1206/4/2/9/3/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/dcm/dcmOpsStatus/dcmReset
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional

Enumerated values

ValueName
1other
2hardReset
3softReset
4commReset
5factoryReset
6userReset
7tableClear

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.9.3.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

dcmReset OBJECT-TYPE
 SYNTAX INTEGER
 {
   other (1),
   hardReset (2),
   softReset (3),
   commReset (4),
   factoryReset (5),
   userReset (6),
   tableClear (7)
 }
 ACCESS read-write
 STATUS optional
 DESCRIPTION
 "indicates the different types of resets that may be issued to the dcm
device. The values and their meaning are:
1=Other
2=Hard Reset
          - (restart program, reset comms, clear all user settings, reset
             sensor boards, reset keyboard/display, reset cpu program memory,
             does not clear data files, resets to all factory defaults, stops
             current recording study)
3=Soft Reset
             - (restart program, does not reset comms, does not change user
                settings, does not reset sensor boards, resets
                keyboard/display, resets cpu program memory, does not clear



                                                                                        

                      
       



                     data files, does not reset to factory defaults, stops    current
                     recording study)
4=Comms Reset
            -        Resets the comms channel used to communicate with the field
                     unit to user defaults.
                 -   It is recommended that all required elements are resynched by
                     the dcm device to ensure that communications is not lost with
                     the dcm unit (e.g. modem).
5=Factory Reset
            - User settings consist of all structures that can be written to.
            - Resets all user settings to factory defaults.
6=User Reset
            - Which objects/tables to reset and the values to reset them to
                is configured by the dcmURCTTable
7=Table Clear
            - The clear operation is based on the dcmTableClearTable
"
::= {dcmOpsStatus 1}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

indicates the different types of resets that may be issued to the dcm device. The values and their meaning are: 1=Other 2=Hard Reset - (restart program, reset comms, clear all user settings, reset sensor boards, reset keyboard/display, reset cpu program memory, does not clear data files, resets to all factory defaults, stops current recording study) 3=Soft Reset - (restart program, does not reset comms, does not change user settings, does not reset sensor boards, resets keyboard/display, resets cpu program memory, does not clear data files, does not reset to factory defaults, stops current recording study) 4=Comms Reset - Resets the comms channel used to communicate with the field unit to user defaults. - It is recommended that all required elements are resynched by the dcm device to ensure that communications is not lost with the dcm unit (e.g. modem). 5=Factory Reset - User settings consist of all structures that can be written to. - Resets all user settings to factory defaults. 6=User Reset - Which objects/tables to reset and the values to reset them to is configured by the dcmURCTTable 7=Table Clear - The clear operation is based on the dcmTableClearTable

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 1

dcmReset · optionalNTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: optional.

Names: dcmReset

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dcmReset",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "hardReset",
    "(",
    "2",
    ")",
    ",",
    "softReset",
    "(",
    "3",
    ")",
    ",",
    "commReset",
    "(",
    "4",
    ")",
    ",",
    "factoryReset",
    "(",
    "5",
    ")",
    ",",
    "userReset",
    "(",
    "6",
    ")",
    ",",
    "tableClear",
    "(",
    "7",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"indicates the different types of resets that may be issued to the dcm device. The values and their meaning are: 1=Other 2=Hard Reset - (restart program, reset comms, clear all user settings, reset sensor boards, reset keyboard/display, reset cpu program memory, does not clear data files, resets to all factory defaults, stops current recording study) 3=Soft Reset - (restart program, does not reset comms, does not change user settings, does not reset sensor boards, resets keyboard/display, resets cpu program memory, does not clear data files, does not reset to factory defaults, stops current recording study) 4=Comms Reset - Resets the comms channel used to communicate with the field unit to user defaults. - It is recommended that all required elements are resynched by the dcm device to ensure that communications is not lost with the dcm unit (e.g. modem). 5=Factory Reset - User settings consist of all structures that can be written to. - Resets all user settings to factory defaults. 6=User Reset - Which objects/tables to reset and the values to reset them to is configured by the dcmURCTTable 7=Table Clear - The clear operation is based on the dcmTableClearTable \"",
    "::=",
    "{",
    "dcmOpsStatus",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "hardReset",
            2
          ],
          [
            "softReset",
            3
          ],
          [
            "commReset",
            4
          ],
          [
            "factoryReset",
            5
          ],
          [
            "userReset",
            6
          ],
          [
            "tableClear",
            7
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "indicates the different types of resets that may be issued to the dcm device. The values and their meaning are: 1=Other 2=Hard Reset - (restart program, reset comms, clear all user settings, reset sensor boards, reset keyboard/display, reset cpu program memory, does not clear data files, resets to all factory defaults, stops current recording study) 3=Soft Reset - (restart program, does not reset comms, does not change user settings, does not reset sensor boards, resets keyboard/display, resets cpu program memory, does not clear data files, does not reset to factory defaults, stops current recording study) 4=Comms Reset - Resets the comms channel used to communicate with the field unit to user defaults. - It is recommended that all required elements are resynched by the dcm device to ensure that communications is not lost with the dcm unit (e.g. modem). 5=Factory Reset - User settings consist of all structures that can be written to. - Resets all user settings to factory defaults. 6=User Reset - Which objects/tables to reset and the values to reset them to is configured by the dcmURCTTable 7=Table Clear - The clear operation is based on the dcmTableClearTable"
    ],
    null,
    null,
    null,
    null
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1206:2005, Object Definitions for Data Collection and Monitoring (DCM) Devices Published November 2005 — original PDF · Official record

    Module: DCM-MIB1

    See published definition above

    Module imports
    {'TMIB-II': ['devices'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB-II. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1206v0123f.pdf — DCM-MIB1 (MIB transcription)
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1206:2005, Object Definitions for Daqta Collection and Monitoring (DCM) Devices Published November 2005 (superceded by NTCIP 1206 v02) — original PDF · Official record

    Module: DCM-MIB1

    Same published definition

    Module imports
    {'TMIB-II': ['devices'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: TMIB-II. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1206v0123f-1.pdf — DCM-MIB1 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.9.3.2 dcmTCTMaxNumRows00
1.3.6.1.4.1.1206.4.2.9.3.3 dcmTCTCurNumRows00
1.3.6.1.4.1.1206.4.2.9.3.4 dcmTableClearTable15
1.3.6.1.4.1.1206.4.2.9.3.5 dcmNumUserConfigs00
1.3.6.1.4.1.1206.4.2.9.3.6 dcmURCTMaxNumRows00
1.3.6.1.4.1.1206.4.2.9.3.7 dcmURCTCurNumRows00
1.3.6.1.4.1.1206.4.2.9.3.8 dcmURCTTable15
1.3.6.1.4.1.1206.4.2.9.3.9 dcmOCIDTMaxNumRows00
1.3.6.1.4.1.1206.4.2.9.3.10 dcmOCIDTCurNumRows00
1.3.6.1.4.1.1206.4.2.9.3.11 dcmOCITable15