OID reference

inletSensorStateChange

1.3.6.1.4.1.13742.6.0.61

Description

Inlet sensor state change. Which value field to use depends on the metadata of the sensor. measurementsInletSensorValue is undefined for sensors which can have negative readings, measurementsInletSensorSignedValue is undefined for sensors whose range exceeds the Integer32 range. Both fields do not apply to sensors wit…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.13742.6.0 (traps)
Node code
61
Node name
inletSensorStateChange
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.13742.6.0.61
URN notation
urn:oid:1.3.6.1.4.1.13742.6.0.61
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 13742 6 0 61}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) aphel(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raritan(13742) pdu2(6) traps(0) inletSensorStateChange(61)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/13742/6/0/61
  • /ISO/Identified-Organization/6/1/4/1/13742/6/0/61
  • /ISO/3/6/1/4/1/13742/6/0/61
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/aphel/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/enterprise/raritan/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/enterprises/aphel/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/enterprises/raritan/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/aphel/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raritan/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/aphel/pdu2/traps/inletSensorStateChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/raritan/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/enterprise/aphel/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/enterprise/raritan/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/enterprises/aphel/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/enterprises/raritan/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/ldap-enterprise/aphel/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/ldap-enterprise/raritan/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/vendor-objects/aphel/pdu2/traps/inletSensorStateChange
  • /iso/org/dod/internet/private/vendor-objects/raritan/pdu2/traps/inletSensorStateChange
  • Additional combinations skipped.

The displayed source records contain one distinct definition. Compare its source records.

inletSensorStateChange NOTIFICATION-TYPE
    OBJECTS { pduName,
              pduNumber,
              pxInetAddressType,
              pxInetIPAddress,
              agentInetPortNumber,
              inletLabel,
              typeOfSensor,
              measurementsInletSensorTimeStamp,
              measurementsInletSensorValue,
              measurementsInletSensorState,
              measurementsInletSensorSignedValue,
              oldSensorState,
              sysContact,
              sysName,
              sysLocation,
              pduSerialNumber }
    STATUS current
    DESCRIPTION
           "Inlet sensor state change.
            Which value field to use depends on the metadata of the sensor.
            measurementsInletSensorValue is undefined for sensors which can
            have negative readings, measurementsInletSensorSignedValue is
            undefined for sensors whose range exceeds the Integer32 range.
            Both fields do not apply to sensors without numerical readings.

            For an rcmState sensor transitioning to the fail state, the value is the residual current
            just before the sensor transitioned to the fail state i.e.
            if typeOfSensor = rcmState and measurementsInletSensorState = fail,
            then measurementsInletSensorValue = the residual current just before the sensor transitioned to the fail state"
    ::= { traps 61 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Inlet sensor state change. Which value field to use depends on the metadata of the sensor. measurementsInletSensorValue is undefined for sensors which can have negative readings, measurementsInletSensorSignedValue is undefined for sensors whose range exceeds the Integer32 range. Both fields do not apply to sensors without numerical readings. For an rcmState sensor transitioning to the fail state, the value is the residual current just before the sensor transitioned to the fail state i.e. if typeOfSensor = rcmState and measurementsInletSensorState = fail, then measurementsInletSensorValue = the residual current just before the sensor transitioned to the fail state

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

inletSensorStateChange · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: inletSensorStateChange

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "inletSensorStateChange",
    "NOTIFICATION-TYPE",
    "OBJECTS",
    "{",
    "pduName",
    ",",
    "pduNumber",
    ",",
    "pxInetAddressType",
    ",",
    "pxInetIPAddress",
    ",",
    "agentInetPortNumber",
    ",",
    "inletLabel",
    ",",
    "typeOfSensor",
    ",",
    "measurementsInletSensorTimeStamp",
    ",",
    "measurementsInletSensorValue",
    ",",
    "measurementsInletSensorState",
    ",",
    "measurementsInletSensorSignedValue",
    ",",
    "oldSensorState",
    ",",
    "sysContact",
    ",",
    "sysName",
    ",",
    "sysLocation",
    ",",
    "pduSerialNumber",
    "}",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Inlet sensor state change. Which value field to use depends on the metadata of the sensor. measurementsInletSensorValue is undefined for sensors which can have negative readings, measurementsInletSensorSignedValue is undefined for sensors whose range exceeds the Integer32 range. Both fields do not apply to sensors without numerical readings. For an rcmState sensor transitioning to the fail state, the value is the residual current just before the sensor transitioned to the fail state i.e. if typeOfSensor = rcmState and measurementsInletSensorState = fail, then measurementsInletSensorValue = the residual current just before the sensor transitioned to the fail state\"",
    "::=",
    "{",
    "traps",
    "61",
    "}"
  ],
  "syntax_tree": [
    [
      "Objects",
      [
        "pduName",
        "pduNumber",
        "pxInetAddressType",
        "pxInetIPAddress",
        "agentInetPortNumber",
        "inletLabel",
        "typeOfSensor",
        "measurementsInletSensorTimeStamp",
        "measurementsInletSensorValue",
        "measurementsInletSensorState",
        "measurementsInletSensorSignedValue",
        "oldSensorState",
        "sysContact",
        "sysName",
        "sysLocation",
        "pduSerialNumber"
      ]
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Inlet sensor state change. Which value field to use depends on the metadata of the sensor. measurementsInletSensorValue is undefined for sensors which can have negative readings, measurementsInletSensorSignedValue is undefined for sensors whose range exceeds the Integer32 range. Both fields do not apply to sensors without numerical readings. For an rcmState sensor transitioning to the fail state, the value is the residual current just before the sensor transitioned to the fail state i.e. if typeOfSensor = rcmState and measurementsInletSensorState = fail, then measurementsInletSensorValue = the residual current just before the sensor transitioned to the fail state"
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.13742)

Yang Allen

Siblings (111)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.13742.6.0.0 trapInformation6169
1.3.6.1.4.1.13742.6.0.1 systemStarted00
1.3.6.1.4.1.13742.6.0.2 systemReset00
1.3.6.1.4.1.13742.6.0.3 userLogin00
1.3.6.1.4.1.13742.6.0.4 userLogout00
1.3.6.1.4.1.13742.6.0.5 userAuthenticationFailure00
1.3.6.1.4.1.13742.6.0.8 userSessionTimeout00
1.3.6.1.4.1.13742.6.0.11 userAdded00
1.3.6.1.4.1.13742.6.0.12 userModified00
1.3.6.1.4.1.13742.6.0.13 userDeleted00
1.3.6.1.4.1.13742.6.0.14 roleAdded00
1.3.6.1.4.1.13742.6.0.15 roleModified00
1.3.6.1.4.1.13742.6.0.16 roleDeleted00
1.3.6.1.4.1.13742.6.0.20 deviceUpdateStarted00
1.3.6.1.4.1.13742.6.0.21 deviceUpdateCompleted00
1.3.6.1.4.1.13742.6.0.22 userBlocked00
1.3.6.1.4.1.13742.6.0.23 powerControl00
1.3.6.1.4.1.13742.6.0.24 userPasswordChanged00
1.3.6.1.4.1.13742.6.0.28 passwordSettingsChanged00
1.3.6.1.4.1.13742.6.0.38 firmwareValidationFailed00
1.3.6.1.4.1.13742.6.0.41 logFileCleared00
1.3.6.1.4.1.13742.6.0.53 bulkConfigurationSaved00
1.3.6.1.4.1.13742.6.0.54 bulkConfigurationCopied00
1.3.6.1.4.1.13742.6.0.60 pduSensorStateChange00
1.3.6.1.4.1.13742.6.0.62 inletPoleSensorStateChange00
1.3.6.1.4.1.13742.6.0.63 outletSensorStateChange00
1.3.6.1.4.1.13742.6.0.64 outletPoleSensorStateChange00
1.3.6.1.4.1.13742.6.0.65 overCurrentProtectorSensorStateChange00
1.3.6.1.4.1.13742.6.0.66 externalSensorStateChange00
1.3.6.1.4.1.13742.6.0.67 smtpMessageTransmissionFailure00
1.3.6.1.4.1.13742.6.0.68 ldapError00
1.3.6.1.4.1.13742.6.0.70 deviceUpdateFailed00
1.3.6.1.4.1.13742.6.0.71 loadSheddingModeEntered00
1.3.6.1.4.1.13742.6.0.72 loadSheddingModeExited00
1.3.6.1.4.1.13742.6.0.73 pingServerEnabled00
1.3.6.1.4.1.13742.6.0.74 pingServerDisabled00
1.3.6.1.4.1.13742.6.0.75 serverNotReachable00
1.3.6.1.4.1.13742.6.0.76 serverReachable00
1.3.6.1.4.1.13742.6.0.77 rfCodeTagConnected00
1.3.6.1.4.1.13742.6.0.78 rfCodeTagDisconnected00
1.3.6.1.4.1.13742.6.0.79 deviceIdentificationChanged00
1.3.6.1.4.1.13742.6.0.80 usbExpansionUnitConnected00
1.3.6.1.4.1.13742.6.0.81 usbExpansionUnitDisconnected00
1.3.6.1.4.1.13742.6.0.82 lhxSupportChanged00
1.3.6.1.4.1.13742.6.0.83 userAcceptedRestrictedServiceAgreement00
1.3.6.1.4.1.13742.6.0.84 userDeclinedRestrictedServiceAgreement00
1.3.6.1.4.1.13742.6.0.85 wireSensorStateChange00
1.3.6.1.4.1.13742.6.0.86 transferSwitchSensorStateChange00
1.3.6.1.4.1.13742.6.0.88 deviceSettingsSaved00
1.3.6.1.4.1.13742.6.0.89 deviceSettingsRestored00