A swSensorScn(2) is generated whenever an
environment sensor changes its operational state. For instance,
a fan stop working. The VarBind in the Trap Data Unit shall
contain the corresponding instance of the sensor
status, sensor index, sensor type, sensor value (reading)
and sensor information. Note that the sensor information
contains the type of sensor and its number in textual format.
Parsed from file v2.0.1aSW.mib.txt
Company: None
Module: SW-MIB
A swSensorScn(2) is generated whenever an
environment sensor changes its operational state. For instance,
a fan stop working. The VarBind in the Trap Data Unit shall
contain the corresponding instance of the sensor
status, sensor index, sensor type, sensor value (reading)
and sensor information. Note that the sensor information
contains the type of sensor and its number in textual format.
Parsed from file SW-MIB.mib
Module: SW-MIB
Vendor: Brocade Communications Systems, Inc.
Module: SW-MIB
[Automatically extracted from oidview.com]
swSensorScn NOTIFICATION-TYPE OBJECTS { swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo, swSsn, swGroupName, swGroupType, swGroupMemPos } STATUS current DESCRIPTION "A swSensorScn(2) is generated whenever an environment sensor changes its operational state. For instance, a fan stop working. The VarBind in the Trap Data Unit shall contain the corresponding instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor information. Note that the sensor information contains the type of sensor and its number in textual format." ::= { swTrapsV2 2 }
swSensorScn NOTIFICATION-TYPE OBJECTS { swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo, swSsn, swGroupName, swGroupType, swGroupMemPos } STATUS current DESCRIPTION "A swSensorScn(2) is generated whenever an environment sensor changes its operational state. For instance, a fan stop working. The VarBind in the Trap Data Unit shall contain the corresponding instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor information. Note that the sensor information contains the type of sensor and its number in textual format." ::= { swTrapsV2 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1588.2.1.1.1.0.1 | swFault | 0 | 0 | Obsoleted this trap as firmware doesn't support this trap. A swFault(1) is generated whenever the diagnostics detects a fault wit… |
1.3.6.1.4.1.1588.2.1.1.1.0.3 | swFCPortScn | 0 | 0 | A swFCPortScn(3) is generated whenever an FC_Port changes its operational state. For instance, the FC_Port goes from on-line to o… |
1.3.6.1.4.1.1588.2.1.1.1.0.4 | swEventTrap | 0 | 0 | This trap is generated when an event whose level at or below swEventTrapLevel occurs. |
1.3.6.1.4.1.1588.2.1.1.1.0.5 | swFabricWatchTrap | 0 | 0 | swFabricWatchtrap |
1.3.6.1.4.1.1588.2.1.1.1.0.6 | swTrackChangesTrap | 0 | 0 | trap to be sent for tracking login/logout/config changes |