This table includes the BERT parameters, counters and
commands.
The configurable parameters:
- prtBertPattern
- prtBertInjectRate
- prtBertTs
are not Set per configuration (same for all Configurations)
but start being applied by the Agent only upon successful
Update/Download operation. Therefore, Set will enter the
values to the Temporary Configuration of the agent, while
Get will get the values of the Active Configuration.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This table includes the BERT parameters, counters and
commands.
The configurable parameters:
- prtBertPattern
- prtBertInjectRate
- prtBertTs
are not Set per configuration (same for all Configurations)
but start being applied by the Agent only upon successful
Update/Download operation. Therefore, Set will enter the
values to the Temporary Configuration of the agent, while
Get will get the values of the Active Configuration.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
prtBertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration." ::= { prtGen 5 }
prtBertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtBertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration." ::= { prtGen 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.1.5.1 | prtBertEntry | 13 | 13 | An entry in table. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.1.1 | prtGenParamTable | 1 | 20 | A table. |
1.3.6.1.4.1.164.3.3.3.1.2 | prtGenTestDurationTable | 1 | 4 | A table. |
1.3.6.1.4.1.164.3.3.3.1.3 | prtGenTsTable | 1 | 7 | The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch),exept some products which enable direc… |
1.3.6.1.4.1.164.3.3.3.1.4 | prtAlr | 2 | 14 | None |
1.3.6.1.4.1.164.3.3.3.1.6 | prtMonTable | 1 | 7 | For DXC, the write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch). |
1.3.6.1.4.1.164.3.3.3.1.7 | prtCfgParam | 1 | 9 | None |