The monitored states that can cause a Non Urgent Alarm to
be raised.There are eight conditions and each is assigned
a value as follows :
1 PAT Program Association Table Error
2 SID Stream Identification Error
4 PMT Program Map Table Error
8 PGM Program Number Missing
16 PCR Program Clock Reference missing
32 204 Packet Byte Count
64 ASI Input Signal Failure
128 CNT Continuity Counter Violation
The number transmitted is the sum of all the values that are selected.
Parsed from file IRT4490MDD-MIB.my.txt
Company: irtelectronics
Module: IRT4490MDD-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
irt4490NURGswitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The monitored states that can cause a Non Urgent Alarm to be raised.There are eight conditions and each is assigned a value as follows : 1 PAT Program Association Table Error 2 SID Stream Identification Error 4 PMT Program Map Table Error 8 PGM Program Number Missing 16 PCR Program Clock Reference missing 32 204 Packet Byte Count 64 ASI Input Signal Failure 128 CNT Continuity Counter Violation The number transmitted is the sum of all the values that are selected." ::= { irt4490Config 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.3.3.4.0 | irt4490NURGswitch | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.3.3.1 | irt4490SIDswitch | 1 | 1 | The setting of the switches to which the incoming Stream ID will be compared. |
1.3.6.1.4.1.16557.3.3.3.2 | irt4490PGMswitch | 1 | 1 | The setting of the switches to which the Program Number will be compared. |
1.3.6.1.4.1.16557.3.3.3.3 | irt4490URGswitch | 1 | 1 | The monitored states that can cause an Urgent Alarm to be raised.There are eight conditions and each is assigned a value as follo… |
1.3.6.1.4.1.16557.3.3.3.5 | irt4490Trap | 1 | 1 | If enabled, Traps will be sent when an Urgent or NonUrgent Alarm occurs. |
1.3.6.1.4.1.16557.3.3.3.6 | irt4490Reset | 1 | 1 | Writing a 2 to this object will cause the agent to reset. |