Urgent alarm is the loss of both inputs.
Non urgent alarm is the loss of only one input.
Parsed from file IRT4521HDA-MIB.my.txt
Company: irtelectronics
Module: IRT4521HDA-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
irt4521Alarms OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), nonUrgentAlarm(2), urgentAlarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Urgent alarm is the loss of both inputs. Non urgent alarm is the loss of only one input." ::= { irt4521HDA 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.49.1.0 | irt4521Alarms | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.16557.3.49.2 | irt4521Status | 6 | 12 | None |
1.3.6.1.4.1.16557.3.49.3 | irt4521Config | 8 | 16 | None |
1.3.6.1.4.1.16557.3.49.4 | irt4521Reset | 1 | 1 | Writing a 2 to this object will cause the agent to reset. |
1.3.6.1.4.1.16557.3.49.5 | irt4521InputAPresTrapEnable | 1 | 1 | If enabled, a trap will be sent on loss of input. A Trap will also be sent when the signal is reapplied. |
1.3.6.1.4.1.16557.3.49.6 | irt4521InputBPresTrapEnable | 1 | 1 | If enabled, a trap will be sent on loss of input. A Trap will also be sent when the signal is reapplied. |
1.3.6.1.4.1.16557.3.49.7 | irt4521OutputARateTrapEnable | 1 | 1 | If enabled, a trap will be sent on change of output rate. |
1.3.6.1.4.1.16557.3.49.8 | irt4521OutputBRateTrapEnable | 1 | 1 | If enabled, a trap will be sent on change of output rate. |