OID reference

swPoESystemInfoPowerDisconnectMethod

1.3.6.1.4.1.171.12.24.2.1.1.5

Description

The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been e…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.171.12.24.2.1.1 (swPoESystemInfoEntry)
Node code
5
Node name
swPoESystemInfoPowerDisconnectMethod
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.171.12.24.2.1.1.5
URN notation
urn:oid:1.3.6.1.4.1.171.12.24.2.1.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 171 12 24 2 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-common-mgmt(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemPowerConsumption(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) nmsModules(12) swPoEMIB(24) swPoESystemInfo(2) swPoESystemInfoTable(1) swPoESystemInfoEntry(1) swPoESystemInfoPowerDisconnectMethod(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/171/12/24/2/1/1/5
  • /ISO/Identified-Organization/6/1/4/1/171/12/24/2/1/1/5
  • /ISO/3/6/1/4/1/171/12/24/2/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/company/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/company/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/company/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/company/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/my/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/my/dlink-common-mgmt/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/my/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemPowerConsumption/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • /iso/identified-organization/dod/internet/private/enterprise/my/nmsModules/swPoEMIB/swPoESystemInfo/swPoESystemInfoTable/swPoESystemInfoEntry/swPoESystemInfoPowerDisconnectMethod
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only, read-write
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — D-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — D-Link official switch MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1denyNextPort1, 2
2denyLowPriorityPort1, 2

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In PoE-MIB, the row index swPoESystemInfoUnitId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.12.24.2.1.1.5.<swPoESystemInfoUnitId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

Published row index variants: swPoESystemInfoBoxId; swPoESystemInfoUnitId.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.12.24.2.1.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

swPoESystemInfoPowerDisconnectMethod · current

swPoESystemInfoPowerDisconnectMethod OBJECT-TYPE
		SYNTAX		INTEGER{
						denyNextPort(1),
						denyLowPriorityPort(2)
						}
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "The power management disconnection method. When the total consumed power
            exceeds the power budget, the PoE controller initiates port disconnection
            to prevent overloading the power supply. The controller uses one of the
            following two ways to implement the disconnection.
            deny_next_port:
            after the power budget has been exceeded, the next port
            attempting to power up is denied, regardless of its priority.
            deny_low_priority_port:
            after the power budget has been exceeded, the next
            port attempting to power up causes the port with the lowest priority to
            shut down to allow high-priority ports to power up.
            The default setting is deny_next_port."
        ::= { swPoESystemInfoEntry 5 }

swPoESystemInfoPowerDisconnectMethod · current

swPoESystemInfoPowerDisconnectMethod OBJECT-TYPE
		SYNTAX		INTEGER{
						denyNextPort(1),
						denyLowPriorityPort(2)
						}
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "The power management disconnection method. When the total consumed power
            exceeds the power budget, the PoE controller initiates port disconnection
            to prevent overloading the power supply. The controller uses one of the
            following two ways to implement the disconnection.
            deny_next_port:
            after the power budget has been exceeded, the next port
            attempting to power up is denied, regardless of its priority.
            deny_low_priority_port:
            after the power budget has been exceeded, the next
            port attempting to power up causes the port with the lowest priority to
            shut down to allow high-priority ports to power up.
            The default setting is deny_next_port."
        ::= { swPoESystemInfoEntry 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.

Sources for this description

D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1D-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)2 records · 9 sources

Description 1

swPoESystemInfoPowerDisconnectMethod · currentD-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)8 sources

Status in source: current.

Names: swPoESystemInfoPowerDisconnectMethod

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "swPoESystemInfoPowerDisconnectMethod",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "denyNextPort",
    "(",
    "1",
    ")",
    ",",
    "denyLowPriorityPort",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.\"",
    "::=",
    "{",
    "swPoESystemInfoEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "denyNextPort",
            1
          ],
          [
            "denyLowPriorityPort",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port."
    ],
    null,
    null,
    null,
    null
  ]
}
swPoESystemInfoPowerDisconnectMethod · currentD-Link official switch MIBs1 source

Status in source: current.

Names: swPoESystemInfoPowerDisconnectMethod

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "swPoESystemInfoPowerDisconnectMethod",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "denyNextPort",
    "(",
    "1",
    ")",
    ",",
    "denyLowPriorityPort",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.\"",
    "::=",
    "{",
    "swPoESystemInfoEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "denyNextPort",
            1
          ],
          [
            "denyLowPriorityPort",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)

Henry P. Nagai

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.171.12.24.2.1.1.1 swPoESystemInfoUnitId, swPoESystemInfoBoxId00
1.3.6.1.4.1.171.12.24.2.1.1.2 swPoESystemInfoPowerConsumption00
1.3.6.1.4.1.171.12.24.2.1.1.3 swPoESystemInfoPowerRemained00
1.3.6.1.4.1.171.12.24.2.1.1.4 swPoESystemInfoPowerLimit00
1.3.6.1.4.1.171.12.24.2.1.1.6 swPoESystemInfoManagementMode00
1.3.6.1.4.1.171.12.24.2.1.1.7 swPoESystemInfoLegacyPD, swL2PoESystemInfoLedState00