Description 1
When set enabled(1), the POE LED is lighten. When set disabled(2), the Link/ACT/Speed LED is lighten.
OID reference
1.3.6.1.4.1.171.12.24.2.1.1.7
When set enabled(1), the POE LED is lighten. When set disabled(2), the Link/ACT/Speed LED is lighten.
Identification
{1 3 6 1 4 1 171 12 24 2 1 1 7}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 1 | enabled | 1, 2 |
| 2 | disabled | 1, 2 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In PoE-MIB, the row index swPoESystemInfoUnitId is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.12.24.2.1.1.7.<swPoESystemInfoUnitId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: swPoESystemInfoBoxId; swPoESystemInfoUnitId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.12.24.2.1.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
swL2PoESystemInfoLedState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set enabled(1), the POE LED is lighten.
When set disabled(2), the Link/ACT/Speed LED is lighten."
::= { swPoESystemInfoEntry 7 }swPoESystemInfoLegacyPD OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of legacy PD detection."
::= { swPoESystemInfoEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
When set enabled(1), the POE LED is lighten. When set disabled(2), the Link/ACT/Speed LED is lighten.
Description 2
The current status of legacy PD detection.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: swL2PoESystemInfoLedState
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swL2PoESystemInfoLedState",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"enabled",
"(",
"1",
")",
",",
"disabled",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"When set enabled(1), the POE LED is lighten. When set disabled(2), the Link/ACT/Speed LED is lighten.\"",
"::=",
"{",
"swPoESystemInfoEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"enabled",
1
],
[
"disabled",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When set enabled(1), the POE LED is lighten. When set disabled(2), the Link/ACT/Speed LED is lighten."
],
null,
null,
null,
null
]
}Module: PoE-MIB
See published definition above
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Status in source: current.
Names: swPoESystemInfoLegacyPD
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swPoESystemInfoLegacyPD",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"enabled",
"(",
"1",
")",
",",
"disabled",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The current status of legacy PD detection.\"",
"::=",
"{",
"swPoESystemInfoEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"enabled",
1
],
[
"disabled",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The current status of legacy PD detection."
],
null,
null,
null,
null
]
}Module: PoE-MIB
See published definition above
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DWS3160_MIB_new_01.04.2015.zip.
Same file in DWS3160_MIB_new_01.04.2015.zip.
Same file in DGS-3000_R1.10_MIB_20140707.zip.
Same file in DGS-3000_R1.10_MIB_20140707.zip.
Module: PoE-MIB
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DGS-3000_R4.00_mibs_20171229_2.zip.
Same file in DGS-3000_R4.00_mibs_20171229_2.zip.
Same file in DGS-3000_R4.00_mibs_20171229_2.zip.
Same file in DGS-3000_R4.00_mibs_20171229_2.zip.
Module: PoE-MIB
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DGS-3620-r3.0-mib-20171011.zip.
Same file in DGS-3620-r3.0-mib-20171011.zip.
Same file in DGS-3620_Series_FW_v2.60.016_MIB.7z.
Same file in DGS-3620-r3.0-mib-20171011.zip.
Module: PoE-MIB
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DGS-3620_Series_FW_v1.00.035_MIB.zip.
Same file in DGS-3120_MIB_of_FW_v2.00.010.zip.rar.
Module: PoE-MIB
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DGS3400_Series_MIB_of_FW _R3.00.7z.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: PoE-MIB
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE'], 'RFC1213-MIB': ['DisplayString'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.12.24.2.1.1.1 | swPoESystemInfoUnitId, swPoESystemInfoBoxId | 0 | 0 | |
| 1.3.6.1.4.1.171.12.24.2.1.1.2 | swPoESystemInfoPowerConsumption | 0 | 0 | |
| 1.3.6.1.4.1.171.12.24.2.1.1.3 | swPoESystemInfoPowerRemained | 0 | 0 | |
| 1.3.6.1.4.1.171.12.24.2.1.1.4 | swPoESystemInfoPowerLimit | 0 | 0 | |
| 1.3.6.1.4.1.171.12.24.2.1.1.5 | swPoESystemInfoPowerDisconnectMethod | 0 | 0 | |
| 1.3.6.1.4.1.171.12.24.2.1.1.6 | swPoESystemInfoManagementMode | 0 | 0 |