OID reference

swPoEPortInfoClass

1.3.6.1.4.1.171.12.24.4.1.1.2

Description

The actual power class of the PD according 802.3af definitions : class 0 : PD power consumption is within 0.44-12.95 watts , class 1 : PD power consumption is within 0.44-3.84 watts , class 2 : PD power consumption is within 3.84-6.49 watts , class 3 : PD power consumption is within 6.49-12.95 watts , class 4 : is res…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.171.12.24.4.1.1 (swPoEPortInfoEntry)
Node code
2
Node name
swPoEPortInfoClass
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.171.12.24.4.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.171.12.24.4.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 171 12 24 4 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) dlink-common-mgmt(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) nmsModules(12) swPoEMIB(24) swPoEPortInfo(4) swPoEPortInfoTable(1) swPoEPortInfoEntry(1) swPoEPortInfoClass(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/171/12/24/4/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/171/12/24/4/1/1/2
  • /ISO/3/6/1/4/1/171/12/24/4/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/company/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/company/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/my/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/my/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/nms/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/dlink/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/dlink/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/d-link/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/d-link/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/company/dlink-common-mgmt/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • /iso/identified-organization/dod/internet/private/enterprises/company/nmsModules/swPoEMIB/swPoEPortInfo/swPoEPortInfoTable/swPoEPortInfoEntry/swPoEPortInfoClass
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–4

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In PoE-MIB, the row index swPoEPortInfoPortIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.12.24.4.1.1.2.<swPoEPortInfoPortIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

Published row index variants: swPoEPortCtrlPortIndex; swPoEPortInfoPortIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.12.24.4.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

swPoEPortInfoClass · current

swPoEPortInfoClass OBJECT-TYPE
		SYNTAX		INTEGER (0..4)
		MAX-ACCESS	read-only
		STATUS		current
		DESCRIPTION
			"The actual power class of the PD according 802.3af definitions :
			class 0 : PD power consumption is within 0.44-12.95 watts ,
			class 1 : PD power consumption is within 0.44-3.84 watts ,
			class 2 : PD power consumption is within 3.84-6.49 watts ,
			class 3 : PD power consumption is within 6.49-12.95 watts ,
			class 4 : is reserved for future use."
		::= { swPoEPortInfoEntry 2 }

swPoEPortInfoClass · current

swPoEPortInfoClass OBJECT-TYPE
		SYNTAX		INTEGER (0..4)
		MAX-ACCESS	read-only
		STATUS		current
		DESCRIPTION
			"The power class of the PD according to 802.3af definitions:
			class 0: PD power consumption is within 0.44-12.95 watts,
			class 1: PD power consumption is within 0.44-3.84 watts,
			class 2: PD power consumption is within 3.84-6.49 watts,
			class 3: PD power consumption is within 6.49-12.95 watts,
			class 4: is reserved for future use."
		::= { swPoEPortInfoEntry 2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The actual power class of the PD according 802.3af definitions : class 0 : PD power consumption is within 0.44-12.95 watts , class 1 : PD power consumption is within 0.44-3.84 watts , class 2 : PD power consumption is within 3.84-6.49 watts , class 3 : PD power consumption is within 6.49-12.95 watts , class 4 : is reserved for future use.

Sources for this description

D-Link official switch MIBs

See 1 matching source record

Description 2

The power class of the PD according to 802.3af definitions: class 0: PD power consumption is within 0.44-12.95 watts, class 1: PD power consumption is within 0.44-3.84 watts, class 2: PD power consumption is within 3.84-6.49 watts, class 3: PD power consumption is within 6.49-12.95 watts, class 4: is reserved for future use.

Sources for this description

D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1D-Link official switch MIBs1 record · 3 sources

Description 1

swPoEPortInfoClass · currentD-Link official switch MIBs3 sources

Status in source: current.

Names: swPoEPortInfoClass

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "swPoEPortInfoClass",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "4",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The actual power class of the PD according 802.3af definitions : class 0 : PD power consumption is within 0.44-12.95 watts , class 1 : PD power consumption is within 0.44-3.84 watts , class 2 : PD power consumption is within 3.84-6.49 watts , class 3 : PD power consumption is within 6.49-12.95 watts , class 4 : is reserved for future use.\"",
    "::=",
    "{",
    "swPoEPortInfoEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The actual power class of the PD according 802.3af definitions : class 0 : PD power consumption is within 0.44-12.95 watts , class 1 : PD power consumption is within 0.44-3.84 watts , class 2 : PD power consumption is within 3.84-6.49 watts , class 3 : PD power consumption is within 6.49-12.95 watts , class 4 : is reserved for future use."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2D-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)1 record · 9 sources

Description 2

swPoEPortInfoClass · currentD-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)9 sources

Status in source: current.

Names: swPoEPortInfoClass

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "swPoEPortInfoClass",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "4",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The power class of the PD according to 802.3af definitions: class 0: PD power consumption is within 0.44-12.95 watts, class 1: PD power consumption is within 0.44-3.84 watts, class 2: PD power consumption is within 3.84-6.49 watts, class 3: PD power consumption is within 6.49-12.95 watts, class 4: is reserved for future use.\"",
    "::=",
    "{",
    "swPoEPortInfoEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The power class of the PD according to 802.3af definitions: class 0: PD power consumption is within 0.44-12.95 watts, class 1: PD power consumption is within 0.44-3.84 watts, class 2: PD power consumption is within 3.84-6.49 watts, class 3: PD power consumption is within 6.49-12.95 watts, class 4: is reserved for future use."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)

Henry P. Nagai

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.171.12.24.4.1.1.1 swPoEPortInfoPortIndex00
1.3.6.1.4.1.171.12.24.4.1.1.3 swPoEPortInfoPower00
1.3.6.1.4.1.171.12.24.4.1.1.4 swPoEPortInfoVoltage00
1.3.6.1.4.1.171.12.24.4.1.1.5 swPoEPortInfoCurrent00
1.3.6.1.4.1.171.12.24.4.1.1.6 swPoEPortInfoStatus00
1.3.6.1.4.1.171.12.24.4.1.1.7 swpoEPortInfoLedStatus00