Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swpoEPortInfoLedStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"on",
"(",
"1",
")",
",",
"off",
"(",
"2",
")",
",",
"error",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The Led display for PoE port status. on(1) : power is provided to the port on which a 802.3af-compliant or legacy PD which is connected, off(2) : no power is provided to the port on which no error happens, error(3): some error happens on the port, like overload, underload, short,...or power budget exceeded conditions.\"",
"::=",
"{",
"swPoEPortInfoEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"on",
1
],
[
"off",
2
],
[
"error",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The Led display for PoE port status. on(1) : power is provided to the port on which a 802.3af-compliant or legacy PD which is connected, off(2) : no power is provided to the port on which no error happens, error(3): some error happens on the port, like overload, underload, short,...or power budget exceeded conditions."
],
null,
null,
null,
null
]
}