Reference record for OID 1.3.6.1.4.1.17373.3.1.8.1


parent
1.3.6.1.4.1.17373.3.1.8 (sensorCountsBase)
node code
1
node name
sensorCounts
dot oid
1.3.6.1.4.1.17373.3.1.8.1
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton(17373) owl(3) deviceInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton(17373) owl(3) productInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) eaton(17373) genesis2(3) deviceInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) eaton(17373) genesis2(3) productInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) eaton(17373) owl(3) deviceInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) eaton(17373) owl(3) productInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton(17373) genesis2(3) deviceInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton(17373) genesis2(3) productInfo(1) sensorCountsBase(8) sensorCounts(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/eaton/owl/deviceInfo/sensorCountsBase/sensorCounts
  • /iso/identified-organization/dod/internet/private/enterprise/eaton/owl/productInfo/sensorCountsBase/sensorCounts
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/eaton/genesis2/deviceInfo/sensorCountsBase/sensorCounts
  • /iso/org/dod/internet/private/enterprise/eaton/genesis2/productInfo/sensorCountsBase/sensorCounts
  • /iso/org/dod/internet/private/enterprises/eaton/owl/deviceInfo/sensorCountsBase/sensorCounts
  • /iso/org/dod/internet/private/enterprises/eaton/owl/productInfo/sensorCountsBase/sensorCounts
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/eaton/genesis2/deviceInfo/sensorCountsBase/sensorCounts
  • /iso/iso-identified-organization/dod/internet/private/enterprises/eaton/genesis2/productInfo/sensorCountsBase/sensorCounts
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/17373/3/1/8/1

    First Registration Authority (recovered by parent 1.3.6.1.4.1.17373)

    Tornow Nick

    Children (34)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.17373.3.1.8.1.2 climateCount 0 0 climateCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of climate monitors curr…
    1.3.6.1.4.1.17373.3.1.8.1.3 powerMonitorCount 0 0 powerMonitorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of power monitors c…
    1.3.6.1.4.1.17373.3.1.8.1.4 tempSensorCount 0 0 tempSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of temperature sensor…
    1.3.6.1.4.1.17373.3.1.8.1.5 airflowSensorCount 0 0 airflowSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of airflow sensors…
    1.3.6.1.4.1.17373.3.1.8.1.6 ctrl3ChDELTACount 0 0 ctrl3ChDELTACount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of DELTA 3 channel …
    1.3.6.1.4.1.17373.3.1.8.1.7 doorSensorCount 0 0 doorSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of door sensors curre…
    1.3.6.1.4.1.17373.3.1.8.1.8 waterSensorCount 0 0 waterSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of water sensors cur…
    1.3.6.1.4.1.17373.3.1.8.1.9 currentSensorCount 0 0 currentSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of current sensors…
    1.3.6.1.4.1.17373.3.1.8.1.10 millivoltSensorCount 0 0 millivoltSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of millivolt sen…
    1.3.6.1.4.1.17373.3.1.8.1.11 power3ChSensorCount 0 0 power3ChSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of 3 channel powe…
    1.3.6.1.4.1.17373.3.1.8.1.12 outletCount 0 0 outletCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of outlets currently plug…
    1.3.6.1.4.1.17373.3.1.8.1.13 vsfcCount 0 0 vsfcCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of fan controller monitors …
    1.3.6.1.4.1.17373.3.1.8.1.14 ctrl3ChCount 0 0 ctrl3ChCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of 3 channel controllers…
    1.3.6.1.4.1.17373.3.1.8.1.15 ctrlGrpAmpsCount 0 0 ctrlGrpAmpsCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of amperage controll…
    1.3.6.1.4.1.17373.3.1.8.1.16 ctrlOutletCount 0 0 ctrlOutletCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of monitored or switc…
    1.3.6.1.4.1.17373.3.1.8.1.17 dewpointSensorCount 0 0 dewpointSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of dewpoint senso…
    1.3.6.1.4.1.17373.3.1.8.1.18 digitalSensorCount 0 0 digitalSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of digital sensors…
    1.3.6.1.4.1.17373.3.1.8.1.19 dstsSensorCount 0 0 dstsSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of DSTS controllers c…
    1.3.6.1.4.1.17373.3.1.8.1.20 cpmSensorCount 0 0 cpmSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of city power sensors …
    1.3.6.1.4.1.17373.3.1.8.1.21 smokeAlarmSensorCount 0 0 smokeAlarmSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of smoke alarm …
    1.3.6.1.4.1.17373.3.1.8.1.22 neg48VdcSensorCount 0 0 neg48VdcSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of -48Vdc sensors…
    1.3.6.1.4.1.17373.3.1.8.1.23 pos30VdcSensorCount 0 0 pos30VdcSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of 30Vdc sensors …
    1.3.6.1.4.1.17373.3.1.8.1.24 analogSensorCount 0 0 analogSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of remote analog in…
    1.3.6.1.4.1.17373.3.1.8.1.25 ctrl3ChIECCount 0 0 ctrl3ChIECCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of IEC 3 channel cont…
    1.3.6.1.4.1.17373.3.1.8.1.26 climateRelayCount 0 0 climateRelayCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of climate relay mo…
    1.3.6.1.4.1.17373.3.1.8.1.27 ctrlRelayCount 0 0 ctrlRelayCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of relay controllers c…
    1.3.6.1.4.1.17373.3.1.8.1.28 airSpeedSwitchSensorCount 0 0 airSpeedSwitchSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of air spee…
    1.3.6.1.4.1.17373.3.1.8.1.29 powerDMCount 0 0 powerDMCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of DM48 current sensors …
    1.3.6.1.4.1.17373.3.1.8.1.30 ioExpanderCount 0 0 ioExpanderCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of IO expander device…
    1.3.6.1.4.1.17373.3.1.8.1.31 t3hdSensorCount 0 0 t3hdSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of T3HD sensors curre…
    1.3.6.1.4.1.17373.3.1.8.1.32 thdSensorCount 0 0 thdSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of THD sensors current…
    1.3.6.1.4.1.17373.3.1.8.1.33 pos60VdcSensorCount 0 0 pos60VdcSensorCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of 60Vdc sensors …
    1.3.6.1.4.1.17373.3.1.8.1.34 ctrl2CirTotCount 0 0 ctrl2CirTotCount OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of IEC 3 channel con…
    1.3.6.1.4.1.17373.3.1.8.1.35 sc10Count 0 0 sc10Count OBJECT-TYPE
    SYNTAX INTEGER(0..16)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Number of fan controller monitors …