Number of RDI cells transmitted.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Number of RDI cells transmitted.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
frAtmPvcVccStatsOamRdiTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RDI cells transmitted." ::= { frAtmPvcVccStatsEntry 29 }
frAtmPvcVccStatsOamRdiTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RDI cells transmitted." ::= { frAtmPvcVccStatsEntry 29 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.12.7.1.1 | frAtmPvcVccStatsIfA | 0 | 0 | Interface index (SSPPCCC) on side A |
1.3.6.1.4.1.1751.2.18.12.7.1.2 | frAtmPvcVccStatsDlciA | 0 | 0 | dlci - side A |
1.3.6.1.4.1.1751.2.18.12.7.1.3 | frAtmPvcVccStatsIfB | 0 | 0 | Interface index (SSPPCCC) on side B |
1.3.6.1.4.1.1751.2.18.12.7.1.4 | frAtmPvcVccStatsVpiB | 0 | 0 | VPI on side B |
1.3.6.1.4.1.1751.2.18.12.7.1.5 | frAtmPvcVccStatsVciB | 0 | 0 | VCI on side B |
1.3.6.1.4.1.1751.2.18.12.7.1.6 | frAtmPvcVccStatsCellsEncodedHiA | 0 | 0 | Cells encoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.7 | frAtmPvcVccStatsCellsEncodedLoA | 0 | 0 | Cells encoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.8 | frAtmPvcVccStatsCellsDecodedHiA | 0 | 0 | Cells decoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.9 | frAtmPvcVccStatsCellsDecodedLoA | 0 | 0 | Cells decoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.10 | frAtmPvcVccStatsInCellCountHiB | 0 | 0 | Valid cells received (Input Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.11 | frAtmPvcVccStatsInCellCountLoB | 0 | 0 | Valid cells received (Input Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.12 | frAtmPvcVccStatsOutCellCountHiB | 0 | 0 | Valid cells transmitted (Output Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.13 | frAtmPvcVccStatsOutCellCountLoB | 0 | 0 | Valid cells transmitted (Output Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.14 | frAtmPvcVccStatsTimer | 0 | 0 | Number of seconds stats have been collecting |
1.3.6.1.4.1.1751.2.18.12.7.1.15 | frAtmPvcVccStatsFramesDroppedA | 0 | 0 | Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side. |
1.3.6.1.4.1.1751.2.18.12.7.1.16 | frAtmPvcVccStatsOdometerCellsEncodedHiA | 0 | 0 | Cells encoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.17 | frAtmPvcVccStatsOdometerCellsEncodedLoA | 0 | 0 | Cells encoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.18 | frAtmPvcVccStatsOdometerCellsDecodedHiA | 0 | 0 | Cells decoded on side A- (High order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.19 | frAtmPvcVccStatsOdometerCellsDecodedLoA | 0 | 0 | Cells decoded on side A- (Low order portion) |
1.3.6.1.4.1.1751.2.18.12.7.1.20 | frAtmPvcVccStatsInOdometerCellCountHiB | 0 | 0 | Valid cells received (Input Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.21 | frAtmPvcVccStatsInOdometerCellCountLoB | 0 | 0 | Valid cells received (Input Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.22 | frAtmPvcVccStatsOutOdometerCellCountHiB | 0 | 0 | Valid cells transmitted (Output Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.23 | frAtmPvcVccStatsOutOdometerCellCountLoB | 0 | 0 | Valid cells transmitted (Output Billing Count) |
1.3.6.1.4.1.1751.2.18.12.7.1.24 | frAtmPvcVccStatsOdometerTimer | 0 | 0 | Number of seconds since odometer was reset. |
1.3.6.1.4.1.1751.2.18.12.7.1.25 | frAtmPvcVccStatsOdometerFramesDroppedA | 0 | 0 | Number of frames dropped for a given DLCI for A2B direction, only applicable to the input side. |
1.3.6.1.4.1.1751.2.18.12.7.1.26 | frAtmPvcVccStatsOdometerReset | 0 | 0 | Odometer reset button. |
1.3.6.1.4.1.1751.2.18.12.7.1.27 | frAtmPvcVccStatsOamAisTx | 0 | 0 | Number of AIS cells transmitted. |
1.3.6.1.4.1.1751.2.18.12.7.1.28 | frAtmPvcVccStatsOamAisRx | 0 | 0 | Number of AIS cells received. |
1.3.6.1.4.1.1751.2.18.12.7.1.30 | frAtmPvcVccStatsOamRdiRx | 0 | 0 | Number of RDI cells received. |
1.3.6.1.4.1.1751.2.18.12.7.1.31 | frAtmPvcVccStatsAal5ErrFramesA | 0 | 0 | Number of Aal5 Errored Frames, which are not dropped due to UPC in A2B dir, only applicable to Input Side |
1.3.6.1.4.1.1751.2.18.12.7.1.32 | frAtmPvcVccStatsFramesTaggedA | 0 | 0 | Number of Frames tagged due to UPC in A2B dir, only applicable to Input Side |
1.3.6.1.4.1.1751.2.18.12.7.1.33 | frAtmPvcVccStatsCellsDroppedB | 0 | 0 | Cells Dropped on the Incoming side of B |
1.3.6.1.4.1.1751.2.18.12.7.1.34 | frAtmPvcVccStatsCellsTaggedB | 0 | 0 | Cells Tagged on the Incoming side of B |