Row definition for GR303 group configuration
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Row definition for GR303 group configuration
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
gr303IgConfigEntry OBJECT-TYPE SYNTAX Gr303IgConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for GR303 group configuration" INDEX { gr303IgId } ::= { gr303IgConfigTable 1 }
gr303IgConfigEntry OBJECT-TYPE SYNTAX Gr303IgConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for GR303 group configuration" INDEX { gr303IgId } ::= { gr303IgConfigTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.26.1.1.1.1 | gr303IgId | 0 | 0 | gr303IgId - 1....84 - index into GR303IG table |
1.3.6.1.4.1.1751.2.18.26.1.1.1.2 | gr303IgRowStatus | 0 | 0 | GR303IG config entry row status |
1.3.6.1.4.1.1751.2.18.26.1.1.1.3 | gr303IgAdminStatus | 0 | 0 | Administrative status of the GR303IG |
1.3.6.1.4.1.1751.2.18.26.1.1.1.4 | gr303IgPrimaryTMCChanIntfId | 0 | 0 | Primary TMC channel Interface Id in SSPPCCC format |
1.3.6.1.4.1.1751.2.18.26.1.1.1.5 | gr303IgPrimaryEOCChanIntfId | 0 | 0 | Primary EOC channel Interface Id in SSPPCCC format |
1.3.6.1.4.1.1751.2.18.26.1.1.1.6 | gr303IgBackupTMCChanIntfId | 0 | 0 | Backup TMC channel Interface Id in SSPPCCC format |
1.3.6.1.4.1.1751.2.18.26.1.1.1.7 | gr303IgBackupEOCChanIntfId | 0 | 0 | Backup EOC channel Interface Id in SSPPCCC format |
1.3.6.1.4.1.1751.2.18.26.1.1.1.8 | gr303IgPrimaryTMCStatus | 0 | 0 | Primary TMC channel Status |
1.3.6.1.4.1.1751.2.18.26.1.1.1.9 | gr303IgPrimaryEOCStatus | 0 | 0 | Primary EOC channel Status |
1.3.6.1.4.1.1751.2.18.26.1.1.1.10 | gr303IgBackupTMCStatus | 0 | 0 | Backup TMC channel Status.Value null(5) Indicates that the Backup TMC has not been configured. |
1.3.6.1.4.1.1751.2.18.26.1.1.1.11 | gr303IgBackupEOCStatus | 0 | 0 | Backup TMC channel Status.Value null(5) Indicates that the Backup EOC has not been configured. |
1.3.6.1.4.1.1751.2.18.26.1.1.1.12 | gr303IgTMCProtSwitchProvState | 0 | 0 | Lock/Unlock the protection switch |
1.3.6.1.4.1.1751.2.18.26.1.1.1.13 | gr303IgEOCProtSwitchProvState | 0 | 0 | Lock/Unlock the protection switch |
1.3.6.1.4.1.1751.2.18.26.1.1.1.14 | gr303IgTMCProtSwitchCommand | 0 | 0 | User command to do path protection switch |
1.3.6.1.4.1.1751.2.18.26.1.1.1.15 | gr303IgEOCProtSwitchCommand | 0 | 0 | User command to do path protection switch |
1.3.6.1.4.1.1751.2.18.26.1.1.1.16 | gr303IgLocalDigitalSwitchType | 0 | 0 | LDS (IDT) type |
1.3.6.1.4.1.1751.2.18.26.1.1.1.17 | gr303IgLocalDigitalSwitchVersion | 0 | 0 | LDS (IDT)Version |