service type
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
service type
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
atmPvcVccServiceTypeA2B OBJECT-TYPE SYNTAX INTEGER { ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10), gfr2(11) } MAX-ACCESS read-write STATUS current DESCRIPTION "service type" DEFVAL { ubr } ::= { atmPvcVccEntry 7 }
atmPvcVccServiceTypeA2B OBJECT-TYPE SYNTAX INTEGER { ubr(1), vbr-nrt2(2), vbr-nrt1(3), vbr-rt2(4), vbr-rt1(5), vbr-express(6), cbr4(7), cbr3(8), cbr2(9), cbr1(10), gfr2(11) } MAX-ACCESS read-write STATUS current DESCRIPTION "service type" DEFVAL { ubr } ::= { atmPvcVccEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.1.1.1 | atmPvcVccIfA | 0 | 0 | Interface index for side A of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC… |
1.3.6.1.4.1.1751.2.18.6.1.1.2 | atmPvcVccVpiA | 0 | 0 | VPI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.1.1.3 | atmPvcVccVciA | 0 | 0 | VCI value for side A of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.1.1.4 | atmPvcVccIfB | 0 | 0 | Interface index for side B of an ATM-to-ATM PVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC… |
1.3.6.1.4.1.1751.2.18.6.1.1.5 | atmPvcVccVpiB | 0 | 0 | VPI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.1.1.6 | atmPvcVccVciB | 0 | 0 | VCI value for side B of an ATM-to-ATM PVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.1.1.8 | atmPvcVccSarTypeA2B | 0 | 0 | SAR type used in atm adaption |
1.3.6.1.4.1.1751.2.18.6.1.1.10 | atmPvcVccPeakCellRateA2B | 0 | 0 | peak cell rate - side A, in cell per second |
1.3.6.1.4.1.1751.2.18.6.1.1.11 | atmPvcVccSusCellRateA2B | 0 | 0 | sustained rate - side A, in cell per second |
1.3.6.1.4.1.1751.2.18.6.1.1.12 | atmPvcVccMaxBurstSizeA2B | 0 | 0 | maximum burst size - side A, in cells |
1.3.6.1.4.1.1751.2.18.6.1.1.13 | atmPvcVccServiceTypeB2A | 0 | 0 | service type |
1.3.6.1.4.1.1751.2.18.6.1.1.14 | atmPvcVccSarTypeB2A | 0 | 0 | sar type used in atm adaption |
1.3.6.1.4.1.1751.2.18.6.1.1.16 | atmPvcVccPeakCellRateB2A | 0 | 0 | peak rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.1.1.17 | atmPvcVccSusCellRateB2A | 0 | 0 | sustained rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.1.1.18 | atmPvcVccMaxBurstSizeB2A | 0 | 0 | maximum burst size - side B, in cells. |
1.3.6.1.4.1.1751.2.18.6.1.1.20 | atmPvcVccType | 0 | 0 | type of connection |
1.3.6.1.4.1.1751.2.18.6.1.1.21 | atmPvcVccFlow | 0 | 0 | type of flow |
1.3.6.1.4.1.1751.2.18.6.1.1.22 | atmPvcVccRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.1.1.23 | atmPvcVccFrwdErrCorrectionA2B | 0 | 0 | Forward error correction scheme |
1.3.6.1.4.1.1751.2.18.6.1.1.24 | atmPvcVccFrwdErrCorrectionB2A | 0 | 0 | Forward error correction scheme |
1.3.6.1.4.1.1751.2.18.6.1.1.25 | atmPvcVccConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.1.1.26 | atmPvcVccOamStatus | 0 | 0 | Indicates the OAM monitoring status of side A. The 5 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only … |
1.3.6.1.4.1.1751.2.18.6.1.1.27 | atmPvcVccDualHomed | 0 | 0 | Does this PVC need a backup Dual homing PVC. |
1.3.6.1.4.1.1751.2.18.6.1.1.28 | atmPvcVccViA | 0 | 0 | VI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.1.1.29 | atmPvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.1.1.30 | atmPvcVccCnfrmTypeA2B | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.1.1.31 | atmPvcVccCnfrmTypeB2A | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.1.1.32 | atmPvcVccVUNIA | 0 | 0 | VUNI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.1.1.33 | atmPvcVccVUNIB | 0 | 0 | VUNI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.1.1.34 | atmPvcVccOamStatusB | 0 | 0 | Indicates the Oam monitoring status of side B of an internal connection. Refer to ITU I.610 and Bellcore GR1248-CORE for definiti… |
1.3.6.1.4.1.1751.2.18.6.1.1.35 | atmPvcVccOAMConnEndPtStatusA | 0 | 0 | Connection endpoint side A status. Valid only at connection endpoint. |
1.3.6.1.4.1.1751.2.18.6.1.1.36 | atmPvcVccOAMConnEndPtStatusB | 0 | 0 | Connection endpoint side B status. Valid only at connection endpoint. |
1.3.6.1.4.1.1751.2.18.6.1.1.37 | atmPvcVccOAMConnSegEndPtStatusA | 0 | 0 | Segment endpoint side A status. Valid only at segment endpoints. |
1.3.6.1.4.1.1751.2.18.6.1.1.38 | atmPvcVccOAMConnSegEndPtStatusB | 0 | 0 | Segment endpoint side B status. Valid only at segment endpoints. |
1.3.6.1.4.1.1751.2.18.6.1.1.39 | atmPvcVccMfsA2B | 0 | 0 | Maximum Frame Size for GFR traffic for A2B dir |
1.3.6.1.4.1.1751.2.18.6.1.1.40 | atmPvcVccMfsB2A | 0 | 0 | Maximum Frame Size for GFR traffic for B2A dir |
1.3.6.1.4.1.1751.2.18.6.1.1.41 | atmPvcVccConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.1.1.42 | atmPvcVccConnFailureCauseB | 0 | 0 | connection status reason code |
1.3.6.1.4.1.1751.2.18.6.1.1.43 | atmPvcVccTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |
1.3.6.1.4.1.1751.2.18.6.1.1.44 | atmPvcVccTrafficShapingB2A | 0 | 0 | Traffic Shaping Support in the B2A direction. |