An entry in the CES DHPVC table. There is one
entry in the table corresponding to each active
row in the cirEmAtmPvcVccTable for which the
cirEmAtmPvcVccDualHomed object takes the value
'yes.'
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
An entry in the CES DHPVC table. There is one
entry in the table corresponding to each active
row in the cirEmAtmPvcVccTable for which the
cirEmAtmPvcVccDualHomed object takes the value
'yes.'
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
cirEmAtmBkPvcVccEntry OBJECT-TYPE SYNTAX CirEmAtmBkPvcVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the CES DHPVC table. There is one entry in the table corresponding to each active row in the cirEmAtmPvcVccTable for which the cirEmAtmPvcVccDualHomed object takes the value 'yes.'" INDEX { cirEmAtmPvcVccIfA, cirEmAtmPvcVccIfB, cirEmAtmPvcVccVpiB, cirEmAtmPvcVccVciB } ::= { cirEmAtmBkPvcVccTable 1 }
cirEmAtmBkPvcVccEntry OBJECT-TYPE SYNTAX CirEmAtmBkPvcVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the CES DHPVC table. There is one entry in the table corresponding to each active row in the cirEmAtmPvcVccTable for which the cirEmAtmPvcVccDualHomed object takes the value 'yes.'" INDEX { cirEmAtmPvcVccIfA, cirEmAtmPvcVccIfB, cirEmAtmPvcVccVpiB, cirEmAtmPvcVccVciB } ::= { cirEmAtmBkPvcVccTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.14.1.1 | cirEmAtmBkPvcVccIfB | 0 | 0 | Interface index for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Number value is interpreted as … |
1.3.6.1.4.1.1751.2.18.6.14.1.2 | cirEmAtmBkPvcVccVpiB | 0 | 0 | VPI value for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Valid range is a number between 0 an… |
1.3.6.1.4.1.1751.2.18.6.14.1.3 | cirEmAtmBkPvcVccVciB | 0 | 0 | VCI value for side B, the atm side, of a backup circuit emulation-atm DHPVC VCC connection. Valid range is a number between 0 an… |
1.3.6.1.4.1.1751.2.18.6.14.1.4 | cirEmAtmBkPvcVccActivePvc | 0 | 0 | Current active PVC. |
1.3.6.1.4.1.1751.2.18.6.14.1.5 | cirEmAtmBkPvcVccAutoSwitch | 0 | 0 | Auto switch back to primary link when primary link is recovered. |
1.3.6.1.4.1.1751.2.18.6.14.1.6 | cirEmAtmBkPvcVccRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.14.1.7 | cirEmAtmBkPvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.14.1.8 | cirEmAtmBkPvcVccVUNIB | 0 | 0 | VUNI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.14.1.9 | cirEmAtmBkPvcVccConnFailureCauseB | 0 | 0 | connection status reason code |