Traffic Shaping Support in the A2B direction.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Traffic Shaping Support in the A2B direction.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
atmSpvcVccTrafficShapingA2B OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic Shaping Support in the A2B direction." DEFVAL { disabled } ::= { atmSpvcVccEntry 26 }
atmSpvcVccTrafficShapingA2B OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic Shaping Support in the A2B direction." DEFVAL { disabled } ::= { atmSpvcVccEntry 26 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.17.1.1 | atmSpvcVccVpiA | 0 | 0 | VPI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.17.1.2 | atmSpvcVccVciA | 0 | 0 | VCI value for side A of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.17.1.3 | atmSpvcVccIfB | 0 | 0 | Interface index for side B of an ATM SPVC VCC connection. Number value is interpreted as an interface of the form, SSPPCCC, wher… |
1.3.6.1.4.1.1751.2.18.6.17.1.4 | atmSpvcVccVpiB | 0 | 0 | VPI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.17.1.5 | atmSpvcVccVciB | 0 | 0 | VCI value for side B of an ATM SPVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.17.1.6 | atmSpvcVccServiceTypeA2B | 0 | 0 | Service type, ATM port. |
1.3.6.1.4.1.1751.2.18.6.17.1.7 | atmSpvcVccSarTypeA2B | 0 | 0 | SAR type used in ATM adaption, ATM port. |
1.3.6.1.4.1.1751.2.18.6.17.1.8 | atmSpvcVccPeakCellRateA2B | 0 | 0 | Peak cell rate - side A, ATM port, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.9 | atmSpvcVccSusCellRateA2B | 0 | 0 | Sustained cell rate - side A, ATM port, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.10 | atmSpvcVccMaxBurstSizeA2B | 0 | 0 | Maximum burst size - side A, ATM port, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.11 | atmSpvcVccFrwdErrCorrectionA2B | 0 | 0 | Forward error correction scheme, ATM port side. |
1.3.6.1.4.1.1751.2.18.6.17.1.12 | atmSpvcVccServiceTypeB2A | 0 | 0 | Service type, ATM trunk side. |
1.3.6.1.4.1.1751.2.18.6.17.1.13 | atmSpvcVccSarTypeB2A | 0 | 0 | SAR type used in ATM adaption, ATM trunk side. |
1.3.6.1.4.1.1751.2.18.6.17.1.14 | atmSpvcVccPeakCellRateB2A | 0 | 0 | Peak cell rate - side B, ATM trunk, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.15 | atmSpvcVccSusCellRateB2A | 0 | 0 | Sustained cell rate - side B, ATM trunk, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.16 | atmSpvcVccMaxBurstSizeB2A | 0 | 0 | Maximum burst size - side A, ATM trunk, in cells per second. |
1.3.6.1.4.1.1751.2.18.6.17.1.17 | atmSpvcVccFrwdErrCorrectionB2A | 0 | 0 | Forward error correction scheme, ATM trunk side. |
1.3.6.1.4.1.1751.2.18.6.17.1.18 | atmSpvcVccFlow | 0 | 0 | Type of flow, pointToMultipointA2B is for future support. |
1.3.6.1.4.1.1751.2.18.6.17.1.19 | atmSpvcVccType | 0 | 0 | Type of connection. |
1.3.6.1.4.1.1751.2.18.6.17.1.20 | atmSpvcVccConnType | 0 | 0 | The type of connection: activeSvc - attempt calls, whenever not established. passiveSvc - accept calls. |
1.3.6.1.4.1.1751.2.18.6.17.1.21 | atmSpvcVccLeafReference | 0 | 0 | An arbitrary integer which serves to distinguish the mulitple leaves attached to a root of a point-to-multipoint SPVC. If point-… |
1.3.6.1.4.1.1751.2.18.6.17.1.22 | atmSpvcVccOperStatus | 0 | 0 | The operation status of the connection: other - none of the types specified below. establishmentInProgress - connection is not ope… |
1.3.6.1.4.1.1751.2.18.6.17.1.23 | atmSpvcVccRowStatus | 0 | 0 | Used to create and delete a soft PVC. When this object is set to 'active', an attempt is made to set up the soft PVC. When this… |
1.3.6.1.4.1.1751.2.18.6.17.1.24 | atmSpvcVccViA | 0 | 0 | VI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.17.1.25 | atmSpvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.17.1.27 | atmSpvcVccTrafficShapingB2A | 0 | 0 | Traffic Shaping Support in the B2A direction. |