Reference record for OID 1.3.6.1.4.1.1751.2.18.6.39.1.6



parent
1.3.6.1.4.1.1751.2.18.6.39.1 (intfAtmPvcConnDisplayEntry)
node code
6
node name
intfAtmPvcConnDisplayFlowType
dot oid
1.3.6.1.4.1.1751.2.18.6.39.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) connectionConfig(6) intfAtmPvcConnDisplayTable(39) intfAtmPvcConnDisplayEntry(1) intfAtmPvcConnDisplayFlowType(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/mibs/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/lucent/mibs/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • /iso/org/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • /iso/org/dod/internet/private/enterprises/lucent/mibs/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • /iso/org/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/mibs/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/connectionConfig/intfAtmPvcConnDisplayTable/intfAtmPvcConnDisplayEntry/intfAtmPvcConnDisplayFlowType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/1751/2/18/6/39/1/6

    Description by mibdepot

    Flow type:Indicates Flow Towards the Back Plane
    cnctnValid: Traffic flow towards BP is enabled.
    cnctnNull: Traffic flow towards BP is disabled.
    cnctnPtmpValid: Traffic flow towards BP is enabled
    and it is point to multipoint
    connection.
    cnctnPtmpNull: Traffic flow towards BP is disabled
    and it is point to multipoint
    connection.

    Parsed from file ac120.my.V07.00.C00.mib.txt
    Company: None
    Module: ACMIB

    Description by circitor

    Flow type:Indicates Flow Towards the Back Plane
    cnctnValid: Traffic flow towards BP is enabled.
    cnctnNull: Traffic flow towards BP is disabled.
    cnctnPtmpValid: Traffic flow towards BP is enabled
    and it is point to multipoint
    connection.
    cnctnPtmpNull: Traffic flow towards BP is disabled
    and it is point to multipoint
    connection.

    Parsed from file ACMIB.mib
    Module: ACMIB

    Information by oid_info

    Vendor: Lucent Technologies
    Module: ACMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    intfAtmPvcConnDisplayFlowType OBJECT-TYPE SYNTAX INTEGER { cnctnValid(1), cnctnNull(2), cnctnPtmpValid(3), cnctnPtmpNull(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flow type:Indicates Flow Towards the Back Plane cnctnValid: Traffic flow towards BP is enabled. cnctnNull: Traffic flow towards BP is disabled. cnctnPtmpValid: Traffic flow towards BP is enabled and it is point to multipoint connection. cnctnPtmpNull: Traffic flow towards BP is disabled and it is point to multipoint connection." ::= { intfAtmPvcConnDisplayEntry 6}

    Information by circitor

    intfAtmPvcConnDisplayFlowType OBJECT-TYPE SYNTAX INTEGER { cnctnValid(1), cnctnNull(2), cnctnPtmpValid(3), cnctnPtmpNull(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flow type:Indicates Flow Towards the Back Plane cnctnValid: Traffic flow towards BP is enabled. cnctnNull: Traffic flow towards BP is disabled. cnctnPtmpValid: Traffic flow towards BP is enabled and it is point to multipoint connection. cnctnPtmpNull: Traffic flow towards BP is disabled and it is point to multipoint connection." ::= { intfAtmPvcConnDisplayEntry 6}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    Richard Bantel

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    HÃ¥kon Helmers

    Brothers (5)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1751.2.18.6.39.1.1 intfAtmPvcConnDisplaySlot 0 0 Slot of the particular interface
    1.3.6.1.4.1.1751.2.18.6.39.1.2 intfAtmPvcConnDisplayPort 0 0 Port of the particular interface
    1.3.6.1.4.1.1751.2.18.6.39.1.3 intfAtmPvcConnDisplayChannel 0 0 Channel of the particular interface
    1.3.6.1.4.1.1751.2.18.6.39.1.4 intfAtmPvcConnDisplayVpi 0 0 VPI value for connection on Intf
    Valid range is a number between 0 and 4095.
    1.3.6.1.4.1.1751.2.18.6.39.1.5 intfAtmPvcConnDisplayVci 0 0 VCI value for connection on Intf
    Valid range is a number between 0 and 65535.